Modified use of the proximal humeral internal locking system (PHILOS) plate for distal femoral nonunions

被引:2
|
作者
Poelmann, Josje [1 ]
Kloen, Peter [1 ]
机构
[1] Univ Amsterdam, Dept Orthoped Surg, Med Ctr, Meiberdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Distal femoral fracture; Nonunion; Dual Plating; Philos; FEMUR FRACTURES; FIXATION; OSTEOSYNTHESIS; MANAGEMENT;
D O I
10.1007/s00590-022-03203-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Nonunion is a common complication after a distal femoral fracture (DFF). Standard treatment consists of revision plating and/or bone grafting. Single lateral plating for a distal femoral nonunion can be insufficient in case of a persistent medial gap and compromised bone stock. Alternatively, dual plating can be used to treat a distal femoral nonunion, but to date there is no Gold standard. The aim of our study was to report our results after use of a minimally invasively placed proximal humeral internal locking system (Philos) plate as a medial buttress in the treatment of a distal femoral nonunion. Methods Fifteen adult patients with a distal femoral nonunion were prospectively entered in a trauma database and retrospectively assessed. All patients underwent a similar operation, which included removal of failed hardware, nonunion debridement, fixation with a lateral plate, and a medial Philos plate combined with bone grafting. Data collected included union rate, time to union, complications and functional outcome. Results In twelve out of fifteen patients (80%), the fracture united after our index operation. Median time to union was 4.8 months (range 1.6-15). Three patients (20%) needed additional bone grafting surgery. One patient underwent a Judet quadricepsplasty. Conclusion This study suggests that the Philos plate is a safe and effective adjunct as a medial buttress plate for distal femoral nonunions.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 50 条
  • [1] Modified use of the proximal humeral internal locking system (PHILOS) plate for distal femoral nonunions
    Josje Poelmann
    Peter Kloen
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 425 - 433
  • [2] Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures
    Sohn, Hoon-Sang
    Shin, Sang-Jin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (07): : 1300 - 1305
  • [3] A New Surgical Technique and Clinical Outcomes of Operated Proximal Metadiaphyseal Humeral Fractures and Nonunions With the Use of Reversed Anatomic Distal Femoral Locking Plate
    Chalidis, Byron
    Kitridis, Dimitrios
    Givissis, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [4] THE RESULTS OF INTERNAL FIXATION OF PROXIMAL HUMERAL OSTEOPOROTIC FRACTURES WITH PHILOS LOCKING PLATE
    Bandalovic, Ante
    Cukelj, Fabijan
    Knezevic, Josip
    Ostojic, Marko
    Pavic, Arsen
    Parac, Zlatko
    Rosin, Matko
    PSYCHIATRIA DANUBINA, 2014, 26 : 20 - 25
  • [5] Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)
    Brunner, Alexander
    Thormann, Sebastian
    Babst, Reto
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1056 - 1063
  • [6] Proximal Humeral Fracture Treated with Proximal Humeral Internal Locking System (PHILOS) via a T-Shaped Small Incision
    Yuan, Feng
    Han, Yingchao
    Pan, Zhangyi
    Ma, Min
    Lu, Liangyu
    Wang, Han
    Zeng, Wen
    Luo, Shulin
    Cai, Junfeng
    Zhou, Wei
    Yin, Feng
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 374 - 377
  • [7] PROXIMAL HUMERAL LOCKING PLATE: A VIABLE ALTERNATIVE FOR FIXATION OF DISTAL FEMORAL FRACTURES IN CHILDREN
    Valenza, Weverley Rubele
    Soni, Jamil Faissal
    Schuta Bodanese, Bruno Henrique
    Rossetto, Deivide Mateus
    De Paula Kosovits, Francisco Guilherme
    Pedroni Cordeiro, Pedro Ivo
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [8] Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures
    Lim, Joon-Ryul
    Yoon, Tae-Hwan
    Choi, Yun-Rak
    Lee, Hwan-Mo
    Chun, Yong-Min
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (09) : 1877 - 1883
  • [9] Addition of a Medial Locking Plate to an In Situ Lateral Locking Plate Results in Healing of Distal Femoral Nonunions
    Holzman, Michael A.
    Hanus, Bryan D.
    Munz, John W.
    O'Connor, Daniel P.
    Brinker, Mark R.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (06) : 1498 - 1505
  • [10] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Jitprapaikulsarn, Surasak
    Neti, Nutdanai
    Thremthakanpon, Witoon
    Gromprasit, Arthit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08) : 1515 - 1521