Detection of Electrically Evoked Auditory Steady-State Responses in Cochlear-Implant Recipients With a System Identification Based Method

被引:2
作者
Schott, Julian [1 ]
Gransier, Robin [2 ]
Wouters, Jan [2 ]
Moonen, Marc [3 ]
机构
[1] Katholieke Univ Leuven, STADIUS Ctr Dynam Syst, Dept Elect Engn ESAT, Signal Proc & Data Analyt, B-3000 Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Neurosci, ExpORL, B-3000 Leuven, Belgium
[3] Katholieke Univ Leuven, STADIUS Ctr Dynam Syst, Dept Elect Engn ESAT, Signal Proc & Data Analyt, Leuven, Belgium
关键词
Cochlear implant; EEG; Objective fitting; Stimulation artifact; System identification; BEHAVIORAL THRESHOLDS; POTENTIALS; ARTIFACT;
D O I
10.1109/TBME.2023.3316838
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Electrically evoked auditory steady-state responses (EASSRs) can potentially be used as an objective measure to realize the automatic fitting of cochlear implants (CIs). They can be recorded using electroencephalography (EEG) and objectively detected at the modulation frequency of the stimulus. The main roadblock in using EASSRs is the presence of CI stimulation artifacts in the EEG recording. In this article, we present an improvement of a recently introduced system identification (SI) based artifact removal method. We evaluate its applicability for objective CI fitting on a larger dataset. Methods: The parameter estimation problem of the SI is solved using ordinary least squares (OLS), where an additional regularization term is added to the cost function. We compare EASSR latencies as determined by the commonly used linear interpolation artifact removal method and SI, to evaluate the artifact removal and EASSR detection quality on a dataset of 16 CI recipients and four different stimulation levels. Results: SI can fully remove stimulation artifacts and detect EASSRs, even for recordings from ipsilateral EEG channels, where all other artifact removal methods fail so far. Using OLS with regularization prevents false positive response detection. Conclusion: Using SI, EASSRs can reliably be detected in EEG recordings, even for ipsilateral recording channels and recordings with lower stimulation levels. As the recordings are obtained with clinically relevant settings of the CI, they reveal the potential impact of SI on the objective fitting of CIs. Significance: We argue, that SI enables therefore a big step towards automated CI fitting with EASSRs.
引用
收藏
页码:738 / 749
页数:12
相关论文
共 39 条
[21]   Short-Term Test-Retest Reliability of Electrically Evoked Cortical Auditory Potentials in Adult Cochlear Implant Recipients [J].
Pike, Meghan ;
Biagio-de Jager, Leigh ;
le Roux, Talita ;
Hofmeyr, Louis M. .
FRONTIERS IN NEUROLOGY, 2020, 11
[22]   Investigation of Electrically Evoked Auditory Brainstem Responses to Multi-Pulse Stimulation of High Frequency in Cochlear Implant Users [J].
Saeedi, Ali ;
Hemmert, Werner .
FRONTIERS IN NEUROSCIENCE, 2020, 14
[23]   Evaluation of noise-induced hearing loss by auditory steady-state and auditory brainstem-evoked responses [J].
Karawani, H. ;
Attias, J. ;
Shemesh, R. ;
Nageris, B. .
CLINICAL OTOLARYNGOLOGY, 2015, 40 (06) :672-681
[24]   Comparing statistics for objective detection of transient and steady-state evoked responses in newborns [J].
Mijares, Eleina ;
Perez Abalo, Maria Cecilia ;
Herrera, Didiesdle ;
Lage, Agustin ;
Vega, Mayrim .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (01) :44-49
[25]   Prediction of aided and unaided audiograms using sound-field auditory steady-state evoked responses [J].
Shemesh, Rafi ;
Attias, Joseph ;
Magdoub, Hassan ;
Nageris, Ben I. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (10) :746-753
[26]   Towards Real-Time Detection of Auditory Steady-State Responses: A Comparative Study [J].
Wang, Lei ;
Noordanus, Elisabeth ;
Van Opstal, Adrianus Johannes .
IEEE ACCESS, 2021, 9 :108975-108991
[27]   Design and implementation of a BCI System based on steady-state visual evoked potentials [J].
Zhang Lei ;
Guo Xiao-jing ;
Wu Xiao-pei .
2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
[28]   System identification method inheriting steady-state characteristics of existing model [J].
Yoshimura, Sho ;
Matsubayashi, Ayaka ;
Inoue, Masaki .
INTERNATIONAL JOURNAL OF CONTROL, 2019, 92 (11) :2701-2711
[29]   Steady-State Visual Evoked Potential based Classification System for Detecting Migraine Seizures [J].
Ko, Li-Wei ;
Lai, Kuan-Lin ;
Huang, Pei-Hua ;
Lin, Chin-Teng ;
Wang, Shuu-Jiun .
2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, :1299-1302
[30]   Identifying Cochlear Implant Channels With Poor Electrode-Neuron Interfaces: Electrically Evoked Auditory Brain Stem Responses Measured With the Partial Tripolar Configuration [J].
Bierer, Julie Arenberg ;
Faulkner, Kathleen F. ;
Tremblay, Kelly L. .
EAR AND HEARING, 2011, 32 (04) :436-444