Experimental Study on No-Load Loss Characteristics of an Alternating Current Excitation Motor

被引:1
作者
Xu, Weihui [1 ]
Ruan, Yushuai [2 ]
Wang, Weishu [1 ]
He, Xiaoke [1 ]
机构
[1] North China Univ Water Resources & Elect Power, Coll Sch Energy & Power Engn, Zhengzhou 450018, Peoples R China
[2] North China Univ Water Resources & Elect Power, Coll Elect Engn, Zhengzhou 450045, Peoples R China
关键词
alternating current excitation motor; experimental research; numerical research; no-load loss;
D O I
10.3390/electronics13010001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An AC excitation power supply will produce a series of harmonic currents in motors compared to the conventional power supply, increase the time harmonic component, and then generate a harmonic magnetic field; harmonics will cause motor vibrations and noise in the motor and will produce a corresponding additional loss, increasing the motor temperature rise; these key technical problems need to be solved in domestic pumped storage AC excitation motor engineering applications. Herein, the no-load loss characteristic test of a 3 MW alternating current excited motor was mainly carried out using a test prototype of the 3 MW alternating current excitation motor. Further, with the aid of the finite element method, the numerical study of the no-load loss characteristics of a 3 MW alternating current excited motor was performed. The relationship between the key factors such as the no-load characteristics, no-load loss characteristics, and constant loss and voltage per unit value is analyzed, and the variation law of the no-load core loss of motors under different loads is explored. The results demonstrate that, under no-load conditions, when the applied voltage was less than the rated voltage, the voltage was proportional to the current. When the applied voltage was more significant than the rated voltage, the current increased as the voltage increased, but the relationship between the two was no longer proportional. The constant loss of the motor maintained a linear relationship with the square of the unit value of the voltage scale. When the square of the unit value of the voltage scale was zero, the loss was equivalent to the wind friction loss under no load. The core loss increased with the increase in load, and the greater the load, the faster the increase rate of the motor iron loss. The comparison deviation between the test and simulation results was less than 10%. The simulation and experimental results verified the effectiveness of finite element modeling and the finite element calculation method.
引用
收藏
页数:14
相关论文
共 26 条
[1]   Principle of Optimal Voltage Regulation and Energy-Saving for Induction Motor With Unknown Constant-Torque Working Condition [J].
Bin, Zhong ;
Lili, Ma ;
Hao, Dong .
IEEE ACCESS, 2020, 8 :187307-187316
[2]  
Damdoum A, 2012, IEEE MEDITERR ELECT, P1151, DOI 10.1109/MELCON.2012.6196632
[3]  
Feltes J., 2013, MODELING ADJUSTABLE
[4]  
Gritli Y, 2010, PROC IEEE INT SYMP, P2607, DOI 10.1109/ISIE.2010.5637995
[5]  
IWADACHI A, 2016, 2016 19 INT C EL MAC, P1
[6]   Experimental study on the influence of high frequency PWM harmonics on the losses of induction motor [J].
Jiang, Meihui ;
Tian, Jun ;
Goh, Hui Hwang ;
Yi, Jiawei ;
Li, Shenwang ;
Zhang, Dongdong ;
Wu, Thomas .
ENERGY REPORTS, 2022, 8 :332-342
[7]  
Kai Ni, 2020, CES Transactions on Electrical Machines and Systems, V4, P339, DOI [10.30941/cestems.2020.00041, 10.30941/CESTEMS.2020.00041]
[8]  
[李晖 Li Hui], 2021, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V41, P6245
[9]   Comparison Between the Salient-Pole Synchronous Machine and the Doubly Fed Induction Machine With Regard to Electromagnetic Parasitic Forces and Stator Vibrations [J].
Lugand, Thomas ;
Schwery, Alexander .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (06) :5284-5294
[10]  
Luo W, 2023, National Remote Sensing Bulletin, V0, P1, DOI 10.11834/jrs.20233056