Combining electrical capacitance and impedance tomography in monitoring processes

被引:3
作者
Klosowski, Grzegorz [1 ]
Adamkiewicz, Przemyslaw [2 ]
Niderla, Konrad [2 ,3 ]
机构
[1] Lublin Univ Technol, Nadbystrzycka 38A, Lublin, Poland
[2] Univ Econ & Innovat, Projektowa 4, Lublin, Poland
[3] Netrix SA, Ctr Res & Dev, Lublin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2023年 / 99卷 / 02期
关键词
machine learning; electrical impedance tomography; electrical capacitance tomography; process tomography; hybrid tomography;
D O I
10.15199/48.2023.02.28
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presented research describes an experiment aimed at answering the question of whether the combination of two types of tomographic measurements, namely electrical impedance tomography (EIT) and electrical capacitance tomography (ECT), will improve the quality of the reconstruction in comparison to the tomographic images obtained with both methods considered separately. For this purpose, appropriate tests were carried out, which showed that, in fact, magnification of the measurement vector by combining EIT and ECT measurements increases the quality of the reconstruction.
引用
收藏
页码:161 / 164
页数:4
相关论文
共 50 条
  • [1] Process Analysis with Electrical Impedance and Capacitance Tomography Data
    Rymarczyk, Tomasz
    Klosowski, Grzegorz
    Kozlowski, Edward
    Rymarczyk, Pawel
    Niderla, Konrad
    2019 APPLICATIONS OF ELECTROMAGNETICS IN MODERN ENGINEERING AND MEDICINE (PTZE), 2019, : 161 - 165
  • [2] Ensemble learning for monitoring process in electrical impedance tomography
    Klosowski, Grzegorz
    Rymarczyk, Tomasz
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2022, 69 (02) : 169 - 178
  • [3] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337
  • [4] Application of electrical capacitance tomography in pharmaceutical manufacturing processes
    Yang, Wuqiang
    Wang, Haigang
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1348 - 1353
  • [5] Energy Efficiency in Measurement and Image Reconstruction Processes in Electrical Impedance Tomography
    Stefaniak, Barbara
    Rymarczyk, Tomasz
    Wojcik, Dariusz
    Cholewa-Wiktor, Marta
    Cieplak, Tomasz
    Orzel, Zbigniew
    Gudowski, Janusz
    Golec, Ewa
    Oleszek, Michal
    Kowalski, Marcin
    ENERGIES, 2024, 17 (23)
  • [6] A configurable electrical capacitance tomography system using a combining electrode strategy
    Yang, Yunjie
    Peng, Lihui
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)
  • [7] Electrical Impedance Tomography for Cardio-Pulmonary Monitoring
    Putensen, Christian
    Hentze, Benjamin
    Muenster, Stefan
    Muders, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)
  • [8] Monitoring of breathing pattern at rest by electrical impedance tomography
    Balleza, Marco
    Fornos, Jaume
    Calaf, Nuria
    Feixas, Teresa
    Gonzalez, Mercedes
    Anton, Daniel
    Riu, Pere
    Casan, Pere
    ARCHIVOS DE BRONCONEUMOLOGIA, 2007, 43 (06): : 300 - 303
  • [9] Compressive sensing in electrical impedance tomography for breathing monitoring
    Shiraz, A.
    Khodadad, D.
    Nordebo, S.
    Yerworth, R.
    Frerichs, I
    van Kaam, A.
    Kallio, M.
    Papadouri, T.
    Bayford, R.
    Demosthenous, A.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (03)
  • [10] The Research Progress of Electrical Impedance Tomography for Lung Monitoring
    Shi, Yan
    Yang, ZhiGuo
    Xie, Fei
    Ren, Shuai
    Xu, ShaoFeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9