MoS2 Modified Screen Printed Carbon Electrode Based Flexible Electrochemical Sensor for Detection of Copper Ions in Water

被引:11
作者
Neethipathi, Deepan Kumar [1 ]
Beniwal, Ajay [1 ]
Bass, Adrian M. [2 ]
Scott, Marian [3 ]
Dahiya, Ravinder [4 ]
机构
[1] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Scotland
[2] Univ Glasgow, Sch Geog & Earth Sci, Glasgow G12 8QQ, Scotland
[3] Univ Glasgow, Sch Math & Stat, Glasgow G12 8SQ, Scotland
[4] Northeastern Univ, Elect & Comp Engn Dept, Bendable Elect & SustainableTechnol BEST Grp, Boston, MA 02115 USA
基金
欧盟地平线“2020”;
关键词
Copper detection; electrochemical sensor; flexible sensor; heavy metal; molybdenum disulfide (MoS2); screen printing; PRECONCENTRATION; BIOSENSOR; TOXICITY; ZINC; LEAD;
D O I
10.1109/JSEN.2023.3257188
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Heavy metal ions (HMI), such as Cu2+, are harmful to the environment and our health. Such ions are typically measured using glassy carbon electrode (GCE)-based electrochemical sensors developed on rigid substrates. However, several emerging applications require such sensors on flexible, and even disposable, substrates. Herein, we present a molybdenum disulfide (MoS2)-modified screen-printed carbon electrode (SPCE)-based flexible electrochemical sensor for the detection of copper ions in the water. The sensor exhibits excellent response with a limit of detection (LOD) of 5.43 mu M for Cu ions in the range of 5 mu M - 5 mM. The developed sensor is compared with MoS2-modified conventional GCE using electrochemical impedance spectroscopy (EIS). The comparative studies show better linearity (R-2 value similar to 0.99) for SPCE-based sensor and underline how easily they can detect Cu ions. The interference study, i.e., detection of copper ions in the presence of other HMI-based analytes, also shows the excellent response of SPCE-based flexible electrochemical sensor-thus, demonstrating their practical application is the detection of Cu in water.
引用
收藏
页码:8146 / 8153
页数:8
相关论文
共 49 条
[11]   Electrochemical Detection of Copper Using a Gly-Gly-His Modified Carbon Nanotube Biosensor [J].
Flavel, Benjamin S. ;
Nambiar, Monessha ;
Shapter, Joseph G. .
SILICON, 2011, 3 (04) :163-171
[12]   COPPER TOXICITY AND CHEMISTRY IN THE ENVIRONMENT - A REVIEW [J].
FLEMMING, CA ;
TREVORS, JT .
WATER AIR AND SOIL POLLUTION, 1989, 44 (1-2) :143-158
[13]   An Ultrasensitive Fluorescence Sensor with Simple Operation for Cu2+ Specific Detection in Drinking Water [J].
Gao, Jinting ;
Yin, Jinjin ;
Tao, Zhanhui ;
Liu, Yaqing ;
Lin, Xiaodong ;
Deng, Jiankang ;
Wang, Shuo .
ACS OMEGA, 2018, 3 (03) :3045-3050
[14]  
Holynska B, 1996, SPECTROCHIM ACTA B, V51, P769
[15]   Self-Powered Active Sensing Based on Triboelectric Generators [J].
Khandelwal, Gaurav ;
Dahiya, Ravinder .
ADVANCED MATERIALS, 2022, 34 (33)
[16]   Two-dimensional mapping of copper and zinc in liver sections by laser ablation-inductively coupled plasma mass spectrometry [J].
Kindness, A ;
Sekaran, CN ;
Feldmann, J .
CLINICAL CHEMISTRY, 2003, 49 (11) :1916-1923
[17]   Easy-to-Use Sensors for Field Monitoring of Copper Contamination in Water and Pesticide-Sprayed Plants [J].
Kirk, Kevin A. ;
Andreescu, Silvana .
ANALYTICAL CHEMISTRY, 2019, 91 (21) :13892-13899
[18]   Electrochemical Biosensing of Dopamine Neurotransmitter: A Review [J].
Lakard, Sophie ;
Pavel, Ileana-Alexandra ;
Lakard, Boris .
BIOSENSORS-BASEL, 2021, 11 (06)
[19]   Determining the Provenance of native copper artifacts from Northeastern North America: evidence from instrumental neutron activation analysis [J].
Levine, Mary Ann .
JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2007, 34 (04) :572-587
[20]   Functionalized polypyrrole nanotube arrays as electrochemical biosensor for the determination of copper ions [J].
Lin, Meng ;
Hu, Xiaoke ;
Ma, Zhaohu ;
Chen, Lingxin .
ANALYTICA CHIMICA ACTA, 2012, 746 :63-69