Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images

被引:4
|
作者
Black, Scott MacDonald [1 ]
Maclean, Craig [2 ]
Barrientos, Pauline Hall [3 ]
Ritos, Konstantinos [4 ,5 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow City, Scotland
[2] Terumo Aort, Res & Dev, Glasgow City, Scotland
[3] Queen Elizabeth Univ Hosp, Clin Phys, NHS Greater Glasgow & Clyde, Glasgow City, Scotland
[4] Dept Mech & Aerosp Engn, Glasgow City, Scotland
[5] Univ Thessaly, Dept Mech Engn, Volos, Greece
基金
英国工程与自然科学研究理事会; 英国科研创新办公室;
关键词
4D Flow-MRI; CT; Aorta; Segmentation; Reconstruction; CFD; WALL SHEAR-STRESS; MAGNETIC-RESONANCE ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; CT ANGIOGRAPHY; RADIATION RISK; BLOOD-FLOW; SEGMENTATION; GADOLINIUM; AORTA; HEMODYNAMICS;
D O I
10.1007/s13239-023-00679-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Segmentation and reconstruction of arterial blood vessels is a fundamental step in the translation of computational fluid dynamics (CFD) to the clinical practice. Four-dimensional flow magnetic resonance imaging (4D Flow-MRI) can provide detailed information of blood flow but processing this information to elucidate the underlying anatomical structures is challenging. In this study, we present a novel approach to create high-contrast anatomical images from retrospective 4D Flow-MRI data.Methods For healthy and clinical cases, the 3D instantaneous velocities at multiple cardiac time steps were superimposed directly onto the 4D Flow-MRI magnitude images and combined into a single composite frame. This new Composite Phase-Contrast Magnetic Resonance Angiogram (CPC-MRA) resulted in enhanced and uniform contrast within the lumen. These images were subsequently segmented and reconstructed to generate 3D arterial models for CFD. Using the time-dependent, 3D incompressible Reynolds-averaged Navier-Stokes equations, the transient aortic haemodynamics was computed within a rigid wall model of patient geometries.Results Validation of these models against the gold standard CT-based approach showed no statistically significant inter-modality difference regarding vessel radius or curvature (p > 0.05), and a similar Dice Similarity Coefficient and Hausdorff Distance. CFD-derived near-wall hemodynamics indicated a significant inter-modality difference (p > 0.05), though these absolute errors were small. When compared to the in vivo data, CFD-derived velocities were qualitatively similar.Conclusion This proof-of-concept study demonstrated that functional 4D Flow-MRI information can be utilized to retrospectively generate anatomical information for CFD models in the absence of standard imaging datasets and intravenous contrast.
引用
收藏
页码:655 / 676
页数:22
相关论文
共 39 条
  • [31] Analysis of Upper Airway Flow Dynamics in Robin Sequence Infants Using 4-D Computed Tomography and Computational Fluid Dynamics
    Michael Barbour
    Clare Richardson
    Mike Bindschadler
    Seth Friedman
    Randall Bly
    John P. Dahl
    Alberto Aliseda
    Annals of Biomedical Engineering, 2023, 51 : 363 - 376
  • [32] Analysis of Upper Airway Flow Dynamics in Robin Sequence Infants Using 4-D Computed Tomography and Computational Fluid Dynamics
    Barbour, Michael
    Richardson, Clare
    Bindschadler, Mike
    Friedman, Seth
    Bly, Randall
    Dahl, John P.
    Aliseda, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (02) : 363 - 376
  • [33] Validation of pressure drop assessment using 4D flow MRI-based turbulence production in various shapes of aortic stenoses
    Ha, Hojin
    Kvitting, John-Peder Escobar
    Dyverfeldt, Petter
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 893 - 906
  • [34] Altered Right Ventricular Kinetic Energy Work Density and Viscous Energy Dissipation in Patients with Pulmonary Arterial Hypertension: A Pilot Study Using 4D Flow MRI
    Han, Q. Joyce
    Witschey, Walter R. T.
    Fang-Yen, Christopher M.
    Arkles, Jeffrey S.
    Barker, Alex J.
    Forfia, Paul R.
    Han, Yuchi
    PLOS ONE, 2015, 10 (09):
  • [35] 3D Reconstruction of Chick Embryo Vascular Geometries Using Non-invasive High-Frequency Ultrasound for Computational Fluid Dynamics Studies
    Tan, Germaine Xin Yi
    Jamil, Muhammad
    Tee, Nicole Gui Zhen
    Zhong, Liang
    Yap, Choon Hwai
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (11) : 2780 - 2793
  • [36] In Vitro Validation of Flow Measurement With Phase Contrast MRI at 3 Tesla Using Stereoscopic Particle Image Velocimetry and Stereoscopic Particle Image Velocimetry-Based Computational Fluid Dynamics
    Khodarahmi, Iman
    Shakeri, Mostafa
    Kotys-Traughber, Melanie
    Fischer, Stefan
    Sharp, M. Keith
    Amini, Amir A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1477 - 1485
  • [37] 3D Vortex-Energetics in the Left Pulmonary Artery for Differentiating Pulmonary Arterial Hypertension and Pulmonary Venous Hypertension Groups Using 4D Flow MRI
    Elbaz, Mohammed S. M.
    Shafeghat, Melika
    Freed, Benjamin H.
    Sarnari, Roberto
    Zilber, Zachary
    Avery, Ryan
    Markl, Michael
    Allen, Bradley D.
    Carr, James
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (05) : 2130 - 2143
  • [38] Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis
    Gottwald, Lukas M.
    Peper, Eva S.
    Zhang, Qinwei
    Coolen, Bram F.
    Strijkers, Gustav J.
    Nederveen, Aart J.
    van Ooij, Pim
    NMR IN BIOMEDICINE, 2020, 33 (04)
  • [39] Hemodynamic evaluation of the pulmonary arteries and aorta using 4D flow cardiac MRI in children and young adults with dextro-transposition of the great arteries after the arterial switch operation
    Calderon, Kylie
    Sodhi, Aparna
    Johnson, Ethan M. I.
    Markl, Michael
    Robinson, Joshua D.
    Rigsby, Cynthia K.