The NuroSleeve, a user-centered 3D printed hybrid orthosis for individuals with upper extremity impairment

被引:3
作者
Khantan, Mehdi [1 ,2 ]
Avery, Mikael [3 ]
Aung, Phyo Thuta [1 ]
Zarin, Rachel M. [1 ]
Hammelef, Emma [1 ]
Shawki, Nabila [1 ]
Serruya, Mijail Demian [1 ]
Napoli, Alessandro [1 ]
机构
[1] Thomas Jefferson Univ, Raphael Ctr Neurorestorat, Philadelphia, PA 19107 USA
[2] Temple Univ, Dept Elect & Comp Engn, Philadelphia, PA 19121 USA
[3] Studio Krea, Collingswood, NJ 08108 USA
关键词
Assistive; Exoskeleton; Hand therapy; Rehabilitation; Stroke; Wearable robotics; Three dimensional (3D) printed active orthoses; Upper extremity impairment; STROKE; REHABILITATION; ROBOT; THERAPY; FINGER; ARM;
D O I
10.1186/s12984-023-01228-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Active upper extremity (UE) assistive devices have the potential to restore independent functional movement in individuals with UE impairment due to neuromuscular diseases or injury-induced chronic weakness. Academically fabricated UE assistive devices are not usually optimized for activities of daily living (ADLs), whereas commercially available alternatives tend to lack flexibility in control and activation methods. Both options are typically difficult to don and doff and may be uncomfortable for extensive daily use due to their lack of personalization. To overcome these limitations, we have designed, developed, and clinically evaluated the NuroSleeve, an innovative user-centered UE hybrid orthosis.Methods This study introduces the design, implementation, and clinical evaluation of the NuroSleeve, a user-centered hybrid device that incorporates a lightweight, easy to don and doff 3D-printed motorized UE orthosis and a functional electrical stimulation (FES) component. Our primary goals are to develop a customized hybrid device that individuals with UE neuromuscular impairment can use to perform ADLs and to evaluate the benefits of incorporating the device into occupational therapy sessions. The trial is designed as a prospective, open-label, single-cohort feasibility study of eight-week sessions combined with at-home use of the device and implements an iterative device design process where feedback from participants and therapists informs design improvement cycles.Results All participants learned how to independently don, doff, and use the NuroSleeve in ADLs, both in clinical therapy and in their home environments. All participants showed improvements in their Canadian Occupational Performance Measure (COPM), which was the primary clinical trial outcome measure. Furthermore, participants and therapists provided valuable feedback to guide further development.Conclusions Our results from non-clinical testing and clinical evaluation demonstrate that the NuroSleeve has met feasibility and safety goals and effectively improved independent voluntary function during ADLs. The study's encouraging preliminary findings indicate that the NuroSleeve has met its technical and clinical objectives while improving upon the limitations of the existing UE orthoses owing to its personalized and flexible approach to hardware and firmware design.
引用
收藏
页数:19
相关论文
共 86 条
  • [61] Micro Linear Actuator, PROGR AUT
  • [62] Moriniére B, 2015, IEEE INT C INT ROBOT, P5333, DOI 10.1109/IROS.2015.7354130
  • [63] Myomo, ABOUT US
  • [64] Neom, 2023, US
  • [65] Feasibility, Safety and Efficacy of a Virtual Reality Exergame System to Supplement Upper Extremity Rehabilitation Post-Stroke: A Pilot Randomized Clinical Trial and Proof of Principle
    Norouzi-Gheidari, Nahid
    Hernandez, Alejandro
    Archambault, Philippe S.
    Higgins, Johanne
    Poissant, Lise
    Kairy, Dahlia
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (01)
  • [66] Inflatable Soft Wearable Robot for Reducing Therapist Fatigue During Upper Extremity Rehabilitation in Severe Stroke
    O'Neill, Ciaran
    Proietti, Tommaso
    Nuckols, Kristin
    Clarke, Megan E.
    Hohimer, Cameron
    Cloutier, Alison
    Lin, David J.
    Walsh, Conor J.
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (03) : 3899 - 3906
  • [67] Omnihi TM, US
  • [68] Mental practice in chronic stroke - Results of a randomized, placebo-controlled trial
    Page, Stephen J.
    Levine, Peter
    Leonard, Anthony
    [J]. STROKE, 2007, 38 (04) : 1293 - 1297
  • [69] ABILHAND: A Rasch-built measure of manual ability
    Penta, M
    Thonnard, JL
    Tesio, L
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (09): : 1038 - 1042
  • [70] Quandt Fanny, 2014, Exp Transl Stroke Med, V6, P9, DOI 10.1186/2040-7378-6-9