An experimental investigation of the mechanical performance of PLLA wire-braided stents

被引:4
|
作者
Lucchetti, Agnese [1 ]
Emonts, Caroline [1 ]
Idrissi, Akram [1 ]
Gries, Thomas [1 ]
Vaughan, Ted J. [2 ]
机构
[1] Rhein Westfal TH Aachen, Inst Textiltech, Aachen, Germany
[2] Univ Galway, Coll Sci & Engn, Biomech Res Ctr BioMEC, Sch Engn, Galway, Ireland
关键词
FLOW DIVERTOR; REVASCULARIZATION; OCCLUSIONS; PARAMETERS; BEHAVIOR; OUTCOMES; DISEASE;
D O I
10.1016/j.jmbbm.2022.105568
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Much of our current understanding of the performance of self-expanding wire-braided stents is based on mechanical testing of Nitinol-based or polymeric nonbioresorbable (e.g. PET, PP etc.) devices. The small amount of data present for bioresorbable devices characterizes stents with big nominal diameters (D > 6 mm), with a distinct lack of data describing the mechanical performance of small-diameter wire-braided bioresorbable devices (D <= 5 mm). This study presents a systematic investigation of the mechanical performance of wire-braided bioresorbable Poly-L-Lactic Acid (PLLA) stents having different braiding angles (alpha = 45 degrees , alpha = 30 degrees, and alpha = 20 degrees), wire diameters (d = 100 mu m, and d = 150 mu m), wire count (n = 24 and n = 48), braiding patterns (1:1-1, 2:2-1 and 1:1-2) and stent diameters (D = 5 mm, D = 4 mm, and D = 2.5 mm). Mechanical characterisation was carried out by evaluating the radial, longitudinal and bending response of the devices. Our results showed that smaller braid angles, larger wire diameters, higher number of wires and smaller stent diameter led to an increase in the stent mechanical properties across each of the three mechanical tests performed. It was found that geometrical features of a polymeric braided stent could be adapted to achieve a similar performance to the one of a metallic device. In particular, substantial increases in stent mechanical properties were found for a low braiding angle and when the braiding pattern followed a one-over-one-under configuration with two wires in parallel (1:1-2). Finally, it was shown that a mathematical model proposed in literature for metal braided stents can provide reasonable predictions also of polymeric stent performance but just in circumstances where wire friction does not have a dominant role. This study presents a wide range of experimental data that can provide an important reference for further development of wire-braided bioresorbable devices.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] SAW CUTS WIRE-BRAIDED HOSE
    GONZALES, EA
    HYDRAULICS & PNEUMATICS, 1971, 24 (05) : 10 - &
  • [2] PROBLEM - CUTTING WIRE-BRAIDED HOSE
    AUDETTE, CO
    HYDRAULICS & PNEUMATICS, 1970, 23 (05) : 10 - &
  • [3] Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents
    Wang, Qian
    Fang, Gang
    Zhao, Yinghong
    Wang, Guohui
    Cai, Tao
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 415 - 427
  • [4] Shape-Setting of Self-Expanding Nickel-Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge
    Bernini, Martina
    Hellmuth, Rudolf
    O'Sullivan, Mike
    Dunlop, Craig
    Mckenna, Ciara G.
    Lucchetti, Agnese
    Gries, Thomas
    Ronan, William
    Vaughan, Ted J.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (03) : 317 - 332
  • [5] Computational analysis of the radial mechanical performance of PLLA coronary artery stents
    Pauck, R. G.
    Reddy, B. D.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 7 - 12
  • [6] A NOVEL WAY TO ASSESS THE MECHANICAL RESPONSE OF SELF-EXPANDING BRAIDED WIRE STENTS
    De Beule, M.
    Verhegghe, B.
    Conti, M.
    Mortier, P.
    Van Impe, R.
    Auricchio, F.
    Verdonck, P.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 626 - 626
  • [7] Modelling and experimental investigation of mechanical performances of braided polyamide sutures
    Debbabi, Faten
    Ben Abdessalem, Saber
    INDIAN JOURNAL OF FIBRE & TEXTILE RESEARCH, 2018, 43 (02) : 186 - 193
  • [8] Virtual optimization of self-expandable braided wire stents
    De Beule, Matthieu
    Van Cauter, Sofie
    Mortier, Peter
    Van Loo, Denis
    Van Impe, Rudy
    Verdonck, Pascal
    Verhegghe, Benedict
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) : 448 - 453
  • [9] An experimental evaluation of the mechanics of bare and polymer-covered self-expanding wire braided stents
    McKenna, Ciara G.
    Vaughan, Ted J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103
  • [10] Selection of helical braided flow diverter stents based on hemodynamic performance and mechanical properties
    Suzuki, Takashi
    Takao, Hiroyuki
    Fujimura, Soichiro
    Dahmani, Chihebeddine
    Ishibashi, Toshihiro
    Mamori, Hiroya
    Fukushima, Naoya
    Yamamoto, Makoto
    Murayama, Yuichi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (10) : 999 - 1005