Methodology and Instrumentation for Electron Paramagnetic Resonance Dosimetry With Tooth Enamel

被引:0
作者
Ghimire, Lekhnath [1 ]
Waller, Edward [1 ]
机构
[1] Ontario Tech Univ, Fac Energy Syst & Nucl Sci, Oshawa, ON L1G 0C5, Canada
来源
JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE | 2023年 / 9卷 / 01期
基金
加拿大自然科学与工程研究理事会;
关键词
X-band CW EPR spectrometer; human tooth enamel; EPR parameters; sample anisotropy; dose reconstruction; EPR DOSE RECONSTRUCTION; L-BAND EPR; RETROSPECTIVE DOSIMETRY; DENTAL ENAMEL; PART; TEETH; SPECTROSCOPY; SAMPLES; SIGNAL; OPTIMIZATION;
D O I
10.1115/1.4055162
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When tooth enamel is exposed to ionizing radiation, it generates a dose-dependent concentration of free radical centers (i.e., unpaired electrons). The concentration of these free radical centers is identified and quantified using electron paramagnetic resonance (EPR) spectroscopy in the form of an EPR spectrum. The intensity of the spectrum is proportional to the absorbed dose. Four international intercomparisons have already demonstrated that the EPR tooth enamel dosimetric technique is reliable for retrospective dose assessment in acute and chronic exposure scenarios. Additionally, EPR dosimetry is regarded same as a gold standard for reconstructing the total lifetime dose of individuals using tooth enamel. The accuracy and reproducibility of EPR dose reconstruction depend on the sample preparation, spectrum acquisition, and EPR spectra analysis techniques. So, this paper reviews some of the widely applied and accepted laboratory protocols or methodologies for the EPR dosimetric methods. The minimum detection limit in tooth enamel using this technique was 30 mGy. So, this review aims to share these protocols so that it would be easy to reconstruct the accident doses or chronic exposures with reliable accuracy and precision. Different bands (e.g., L, X, Q, etc.) continuous wave (CW) EPR spectrometers have been used in many historical and accident dose reconstructions; however, due to the availability, moderate price, and not being much influenced by the small amount of moisture in a sample, the X-band has been widely used. A well-developed methodology, a highly sensitive EPR spectrometer, and a well-trained operator are vital for the reliable measurements of absorbed low doses in EPR dosimetry with tooth enamel.
引用
收藏
页数:13
相关论文
共 60 条
[1]   REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES [J].
Ainsbury, E. A. ;
Bakhanova, E. ;
Barquinero, J. F. ;
Brai, M. ;
Chumak, V. ;
Correcher, V. ;
Darroudi, F. ;
Fattibene, P. ;
Gruel, G. ;
Guclu, I. ;
Horn, S. ;
Jaworska, A. ;
Kulka, U. ;
Lindholm, C. ;
Lloyd, D. ;
Longo, A. ;
Marrale, M. ;
Monteiro Gil, O. ;
Oestreicher, U. ;
Pajic, J. ;
Rakic, B. ;
Romm, H. ;
Trompier, F. ;
Veronese, I. ;
Voisin, P. ;
Vral, A. ;
Whitehouse, C. A. ;
Wieser, A. ;
Woda, C. ;
Wojcik, A. ;
Rothkamm, K. .
RADIATION PROTECTION DOSIMETRY, 2011, 147 (04) :573-592
[2]   IS IONIZING RADIATION HARMFUL AT ANY EXPOSURE? AN ECHO THAT CONTINUES TO VIBRATE [J].
Azzam, Edouard I. ;
Colangelo, Nicholas W. ;
Domogauer, Jason D. ;
Sharma, Neha ;
de Toledo, Sonia M. .
HEALTH PHYSICS, 2016, 110 (03) :249-251
[3]   ESR and NMR dosimetry [J].
Baffa, O ;
Kinoshita, A ;
Abrego, FC ;
Silva, NA .
EPR IN THE 21ST CENTURY: BASICS AND APPLICATIONS TO MATERIAL, LIFE AND EARTH SCIENCES, 2002, :614-623
[4]   Retrospective and emergency dosimetry in response to radiological incidents and nuclear mass-casualty events: A review [J].
Bailiff, I. K. ;
Sholom, S. ;
McKeever, S. W. S. .
RADIATION MEASUREMENTS, 2016, 94 :83-139
[5]  
Barr D., 2008, WORKSH QUANT EPR 31, P125
[6]   EPR tooth dosimetry as a tool for validation of retrospective doses: an end-user perspective [J].
Bhat, M .
APPLIED RADIATION AND ISOTOPES, 2005, 62 (02) :155-161
[7]   IN VIVO DOSIMETRY BY ELECTRON SPIN RESONANCE SPECTROSCOPY [J].
BRADY, JM ;
AARESTAD, NO ;
SWARTZ, HM .
HEALTH PHYSICS, 1968, 15 (01) :43-+
[8]  
Brenner D.J., 2011, NATURE, DOI [10.1038/news.2011.206, DOI 10.1038/NEWS.2011.206]
[9]  
Brustolon M., 2009, ELECT PARAMAGNETIC R, P553
[10]   Lessons of the 3rd International Intercomparison on EPR dosimetry with teeth: Similarities and differences of two successful techniques [J].
Chumak, V. ;
Ciesielski, B. ;
Sholom, S. ;
Schultka, K. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :197-201