Laser-Induced Breakdown Spectroscopy Online Quantitative Analysis for Laser Processing

被引:2
作者
Zhao, Tianzhuo [1 ,2 ]
Zhong, Qixiu [2 ]
Nie, Shuzhen [2 ]
Liu, Xiaolong [2 ]
Xiao, Hong [2 ]
Yin, Chenxuan [1 ,2 ]
Zhong, Fanghui [1 ,2 ]
Ke, Yachen [1 ,2 ]
Li, Fei [1 ]
机构
[1] Univ Chinese Acad Sci, Sch Optoelect, 1 Yanqihu East Rd, Beijing 101408, Peoples R China
[2] Chinese Acad Sci, Aerosp Informat Res Inst, Opt Engn Dept, Dengzhuangnan Rd 9, Beijing 100094, Peoples R China
来源
ADVANCED PHOTONICS RESEARCH | 2024年 / 5卷 / 07期
关键词
laser processing; laser-induced breakdown spectroscopy; libs; online monitoring; spectrum screening; LIBS; CALIBRATION; DIAGNOSTICS; NANOSECOND; PICOSECOND;
D O I
10.1002/adpr.202300293
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Plasma fluctuations, the uncertainty of laser ablation, and bremsstrahlung limit the identification of online element analysis during laser processing and cause difficulty in achieving concentration results with sufficient accuracy and repeatability. A laser-induced breakdown spectroscopy (LIBS) online monitoring system with plasma spatial filtering and spectral screening is proposed to solve this problem. In this system, the high-frequency ablation noise component of the plasma is eliminated using a specially designed optical Fourier filtering structure, and a spectral screening system based on plasma time waveform monitoring is used to suppress the influence of plasma fluctuations. Without noise filters or algorithm optimizations and based only on the basic internal standard method, the calibration curves of all nine elements in the alloy sample exhibits a Pearson's R2 value ranged from 0.91 to 0.99, with a mean of 0.94. The relative standard deviations are all in the range of 3.5%-8.4% with a mean of 5.4%. The accuracy and repeatability are comparable to those of typical LIBS systems. Plasma fluctuation, the uncertainty of laser ablation, bremsstrahlung, and laser processing cannot always achieve valuable quantitative analysis. Using a specially designed optical filtering structure and real-time spectrum screening of laser-induced breakdown spectroscopy (LIBS), valuable quantitative analysis of laser processing online concentration monitoring is achieved for the first time; accuracy and repeatability are comparable to those of a typical LIBS system.image (c) 2024 WILEY-VCH GmbH
引用
收藏
页数:5
相关论文
共 27 条
[1]   Calibration strategies to overcome matrix effects in laser-induced breakdown spectroscopy: Direct calcium and phosphorus determination in solid mineral supplements [J].
Babos, Diego Victor ;
Barros, Ariane Isis ;
Nobrega, Joaquim Araujo ;
Pereira-Filho, Edenir Rodrigues .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 155 :90-98
[2]   Multi-energy calibration (MEC) applied to laser-induced breakdown spectroscopy (LIBS) [J].
Babos, Diego Victor ;
Virgilio, Alex ;
Costa, Vinicius Camara ;
Donati, George Luis ;
Pereira-Filho, Edenir Rodrigues .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) :1753-1762
[3]   Real-time laser-induced plasma monitoring in percussion pulsed laser material processing [J].
Chang, Yuan-Jen ;
Wang, Chih-Yuan ;
Hsu, Jin-Chen ;
Ho, Chao-Ching ;
Kuo, Chia-Lung .
MEASUREMENT, 2019, 135 :905-912
[4]  
Chichkov BN, 1996, APPL PHYS A-MATER, V63, P109, DOI 10.1007/BF01567637
[5]  
Diego-Vallejo D., 2013, PHYS P, V43, P911
[6]   Good practices in LIBS analysis: Review and advices [J].
El Haddad, J. ;
Canioni, L. ;
Bousquet, B. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 :171-182
[7]   Some comparisons of LIBS measurements using nanosecond and picosecond laser pulses [J].
Eland, KL ;
Stratis, DN ;
Lai, TS ;
Berg, MA ;
Goode, SR ;
Angel, SM .
APPLIED SPECTROSCOPY, 2001, 55 (03) :279-285
[8]   The potential of laser-induced breakdown spectrometry for real time monitoring the laser cleaning of archaeometallurgical objects [J].
Fortes, F. J. ;
Cabalin, L. M. ;
Laserna, J. J. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (10) :1191-1197
[9]   Time-Gated Single-Shot Picosecond Laser-Induced Breakdown Spectroscopy (ps-LIBS) for Equivalence-Ratio Measurements [J].
Gragston, Mark ;
Hsu, Paul ;
Patnaik, Anil ;
Zhang, Zhili ;
Roy, Sukesh .
APPLIED SPECTROSCOPY, 2020, 74 (03) :340-346
[10]   Laser-Induced Breakdown Spectroscopy (LIBS), Part I: Review of Basic Diagnostics and Plasma-Particle Interactions: Still-Challenging Issues Within the Analytical Plasma Community [J].
Hahn, David W. ;
Omenetto, Nicolo .
APPLIED SPECTROSCOPY, 2010, 64 (12) :335A-366A