Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and "Virtual TEE" reconstructed from computed tomography for pre-procedural planning of device closure

被引:0
作者
Cho, Natsuki [1 ]
Nakajima, Yoshifumi [1 ]
Kubo, Shunsuke [2 ]
Hara, Hidehiko [3 ]
Nanasato, Mamoru [4 ]
Hozawa, Maiko [1 ]
Doi, Akio [5 ]
Morino, Yoshihiro [1 ]
机构
[1] Iwate Med Univ, Dept Internal Med, Div Cardiol, 2-1-1 Idaidori,Yahaba Cho, Yahaba, Iwate 0283695, Japan
[2] Kurashiki Cent Hosp, Dept Cardiovasc Med, Kurashiki, Okayama, Japan
[3] Toho Univ, Ohashi Med Ctr, Div Cardiovasc Med, Tokyo, Japan
[4] Sakakibara Heart Inst, Dept Cardiol, Tokyo, Japan
[5] Iwate Prefectural Univ, Fac Software & Informat Sci, Iwate, Japan
关键词
Atrial fibrillation; Stroke prevention; Left atrial appendage closure; Pre-procedural imaging; OUTCOMES;
D O I
10.1007/s00380-024-02360-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN (TM) device implantation was statistically compared at 0 degrees, 45 degrees, 90 degrees, and 135 degrees between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.
引用
收藏
页码:539 / 548
页数:10
相关论文
共 15 条
  • [1] Computed tomography measurement for left atrial appendage closure
    Asami, Masahiko
    [J]. CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (03) : 440 - 449
  • [2] Tailor-Made Plate Design and Manufacturing System for Treating Bone Fractures in Small Animals
    Doi, Akio
    Takahashi, Hiroki
    Syuto, Bunei
    Katayama, Masaaki
    Nagashima, Hiroyuki
    Okumura, Masahiro
    [J]. JOURNAL OF ADVANCED COMPUTATIONAL INTELLIGENCE AND INTELLIGENT INFORMATICS, 2013, 17 (04) : 588 - 597
  • [3] Left atrial appendage occlusion with the Amplatzer Amulet: update on device sizing
    Freixa, Xavier
    Aminian, Adel
    Tzikas, Apostolos
    Saw, Jacqueline
    Nielsen-Kudsk, Jens-Erick
    Ghanem, Alexander
    Schmidt, Boris
    Hildick-Smith, David
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (01) : 71 - 78
  • [4] Initial results of transcatheter modification of left atrial appendage by obliteration with device in patients with nonvalvular atrial fibrillation: Real-world data from the TERMINATOR registry
    Hara, Hidehiko
    Kubo, Shunsuke
    Nakajima, Yoshifumi
    Matsumoto, Takashi
    Kondo, Yusuke
    Sugane, Hiroki
    Okubo, Kenji
    Nakagawa, Koji
    Nagatomo, Daisuke
    Hachinohe, Daisuke
    Kusa, Shigeki
    Goya, Masahiko
    Nanasato, Mamoru
    Arita, Takeshi
    Yamasaki, Hiro
    Kuwabara, Kensuke
    Yoshiyama, Tomotaka
    Tanaka, Nobuaki
    Masuda, Masaharu
    Sakamoto, Tomohiro
    Nakashima, Masaki
    Ohno, Yohei
    Saito, Shigeru
    Fukunaga, Masato
    [J]. JOURNAL OF CARDIOLOGY, 2024, 83 (05) : 298 - 305
  • [5] 3D printing for sizing left atrial appendage closure device: head-to-head comparison with computed tomography and transoesophageal echocardiography
    Hell, Michaela M.
    Achenbach, Stephan
    Yoo, In Seong
    Franke, Joerg
    Blachutzik, Florian
    Roether, Jens
    Graf, Verena
    Raaz-Schrauder, Dorette
    Marwan, Mohamed
    Schlundt, Christian
    [J]. EUROINTERVENTION, 2017, 13 (10) : 1234 - 1241
  • [6] 3D-computed tomography to compare the dimensions of the left atrial appendage in patients with normal sinus rhythm and those with paroxysmal atrial fibrillation
    Hozawa, Maiko
    Morino, Yoshihiro
    Matsumoto, Yuki
    Tanaka, Ryoichi
    Nagata, Kyohei
    Kumagai, Akiko
    Tashiro, Atsushi
    Doi, Akio
    Yoshioka, Kunihiro
    [J]. HEART AND VESSELS, 2018, 33 (07) : 777 - 785
  • [8] Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device Results From the PINNACLE FLX Trial
    Kar, Saibal
    Doshi, Shephal K.
    Sadhu, Ashish
    Horton, Rodney
    Osorio, Jose
    Ellis, Christopher
    Stone, James, Jr.
    Shah, Manish
    Dukkipati, Srinivas R.
    Adler, Stuart
    Nair, Devi G.
    Kim, Jamie
    Wazni, Oussama
    Price, Mathew J.
    Asch, Federico M.
    Holmes, David R., Jr.
    Shipley, Robert D.
    Gordon, Nicole T.
    Allocco, Dominic J.
    Reddy, Vivek Y.
    [J]. CIRCULATION, 2021, 143 (18) : 1754 - 1762
  • [9] Expert Recommendations on Cardiac Computed Tomography for Planning Transcatheter Left Atrial Appendage Occlusion
    Korsholm, Kasper
    Berti, Sergio
    Iriart, Xavier
    Saw, Jacqueline
    Wang, Dee Dee
    Cochet, Hubert
    Chow, Danny
    Clemente, Alberto
    De Backer, Ole
    Jensen, Jesper Moller
    Nielsen-Kudsk, Jens Erik
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (03) : 277 - 292
  • [10] Naksuk Niyada, 2016, JACC Clin Electrophysiol, V2, P403, DOI 10.1016/j.jacep.2016.06.006