Efficacy and Safety of CT-Guided Kidney Biopsy for the Diagnosis of Glomerular Diseases in Complicated Patients

被引:2
作者
Vian, Javier [1 ]
Shabaka, Amir [2 ]
Lallena, Silvia [3 ]
Gatius, Serena [1 ]
de la Manzanara, Virginia Lopez [1 ]
Barrera-Ortega, Jeronimo [4 ]
Mendez-Fernandez, Ramiro J. [4 ]
机构
[1] Hosp Univ Clin San Carlos, Nephrol Dept, Madrid, Spain
[2] Hosp Univ Fdn Alcorcon, Nephrol Dept, Madrid, Spain
[3] Univ Complutense Madrid, Fac Med, Madrid, Spain
[4] Hosp Univ Clin San Carlos, Radiol Dept, Madrid, Spain
关键词
Computerized tomography; Ultrasound; Obesity; Diagnosis; Complications; RENAL BIOPSY; UTILITY;
D O I
10.1159/000531378
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Kidney biopsy is the cornerstone for the diagnosis of glomerular diseases and to guide treatment. Percutaneous ultrasound-guided kidney biopsy is currently the gold standard to obtain cortical specimens. However, in cases where ultrasound-guided kidney biopsy is not deemed safe (obese patients, deep kidneys, or kidneys with a complicated anatomy), CT-guided kidney biopsy could be a convenient alternative to obtain renal tissue samples. The aim of this study was to describe the diagnostic yield and complications of CT-guided kidney biopsies in patients with glomerular diseases that were previously discarded for ultrasound-guided kidney biopsy. Material and Methods: We performed a retrospective, single-center, observational study including patients who underwent CT-guided native kidney biopsies in our center after being contraindicated for ultrasound-guided biopsy. Patients' records were reviewed retrieving baseline characteristics and pre-biopsy clinical, laboratory parameters and concomitant medication. The biopsy needle gauge, site of puncture, and number of needle passes were recorded. The diagnostic yield was evaluated by the number of glomeruli obtained, the rate of specimens that were adequate to reach diagnosis, and the number of biopsies that had to be repeated. Complications were defined as minor (hypotension, hematoma) and major (arteriovenous fistulae, major bleeding requiring embolization, or nephrectomy). The diagnostic yield and complications were compared to ultrasound-guided native kidney biopsies performed during the same period. Results: 56 CT-guided native kidney biopsies were performed during the study period. The number of glomeruli obtained per patient was 11.5 & PLUSMN; 6.3, which was inferior to that obtained from ultrasound-guided biopsies (14.08 & PLUSMN; 8.47, p < 0.05). However, the rate of specimens that were adequate to reach a diagnosis was similar (92.9% vs. 90.8%, p = 0.437). The number of needle passes was higher in CT-guided kidney biopsies (2.0 & PLUSMN; 0.7 vs. 1.7 & PLUSMN; 0.5, p < 0.05), as well as the incidence of post-biopsy perirenal asymptomatic hematomas (66.1% vs. 24.5%, p < 0.01). There were no significant differences in other post-biopsy minor complications (1.8% vs. 2.5%, p = 0.621). There were no major complications after CT-guided kidney biopsies. Conclusions: CT-guided percutaneous kidney biopsy is a valid alternative for the diagnosis of glomerular diseases in patients with special characteristics such as obesity or deep kidneys that contraindicate ultrasound-guided biopsy. In this population, CT-guided kidney biopsies are safe and provide a high diagnostic yield, reaching a diagnosis in >90% of patients that had been previously discarded for ultrasound-guided biopsy.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 18 条
  • [1] Agarwal S K, 2013, Indian J Nephrol, V23, P243, DOI 10.4103/0971-4065.114462
  • [2] [Anonymous], 1988, Ann Intern Med, V108, P301
  • [3] Cameron JS, 1997, AM J NEPHROL, V17, P347
  • [4] Bleeding Complications of Native Kidney Biopsy: A Systematic Review and Meta-analysis
    Corapi, Kristin M.
    Chen, Joline L. T.
    Balk, Ethan M.
    Gordon, Craig E.
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2012, 60 (01) : 62 - 73
  • [5] The Current Role of Biopsy in the Diagnosis of Renal Tumors
    Curci, Nicole
    Caoili, Elaine M.
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2017, 38 (01) : 72 - 77
  • [6] Utility of renal biopsy in the clinical management of renal disease
    Dhaun, Neeraj
    Bellamy, Christopher O.
    Cattran, Daniel C.
    Kluth, David C.
    [J]. KIDNEY INTERNATIONAL, 2014, 85 (05) : 1039 - 1048
  • [7] Diagnostic value of CT-guided biopsy of indeterminate renal masses
    Eshed, I
    Elias, S
    Sidi, AA
    [J]. CLINICAL RADIOLOGY, 2004, 59 (03) : 262 - 267
  • [8] Diagnostic utility and safety of transjugular kidney biopsy in the obese patient
    Fine, DM
    Arepally, A
    Hofmann, LV
    Mankowitz, SG
    Atta, MG
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (07) : 1798 - 1802
  • [9] Laparoscopic renal biopsy
    Gimenez, LF
    Micali, S
    Chen, RN
    Moore, RG
    Kavoussi, LR
    Scheel, PJ
    [J]. KIDNEY INTERNATIONAL, 1998, 54 (02) : 525 - 529
  • [10] Role of percutaneous image-guided biopsy in the evaluation of renal masses
    Hara, S
    Miyake, H
    Hara, S
    Arakawa, S
    Hanioka, K
    Kamidono, S
    [J]. UROLOGIA INTERNATIONALIS, 2001, 67 (03) : 199 - 202