Single energy metal artifact reduction performs better than virtual monoenergetic dual-energy reconstruction in CT of the equine proximal phalanx

被引:2
作者
Faulkner, Josephine E. [1 ]
Broeckx, Bart J. G. [2 ]
Martens, Ann [3 ]
Raes, Els [1 ]
Haardt, Hanna [3 ]
Vanderperren, Katrien [1 ]
机构
[1] Univ Ghent, Fac Vet Med, Dept Morphol Imaging Orthoped Rehabil & Nutr, Salisburylaan 133, B-9820 Merelbeke, Belgium
[2] Univ Ghent, Fac Vet Med, Dept Vet & Biosci, Merelbeke, Belgium
[3] Univ Ghent, Fac Vet Med, Dept Large Anim Surg Anesthesia & Orthoped, Ghent, Belgium
关键词
blooming artifact; distal limb; horse; image quality; metal implant; COMPUTED-TOMOGRAPHY; IMAGING FINDINGS; SAGITTAL GROOVE; HORSES; FRACTURES; CONFIGURATION;
D O I
10.1111/vru.13258
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Metal artifacts in CT negatively impact the evaluation of surgical implants and the surrounding tissues. The aim of this prospective experimental study was to evaluate the ability of a single energy metal artifact reduction (SEMAR (TM), Canon) algorithm and virtual monoenergetic (VM) dual-energy CT (DECT) scanning techniques to reduce metal artifacts from stainless steel screws surgically inserted into the equine proximal phalanx. Seven acquisitions of 18 cadaver limbs were performed on a Canon Aquilion One Vision CT scanner (Helical +SEMAR, Volume +SEMAR, Standard Helical, Standard Volume and VM DECT at 135, 120, and 105 keV) and reconstructed in a bone kernel. Blinded subjective evaluation performed by three observers indicated a significant effect of acquisition in both adjacent tissues (P < 0.001) and distant tissues (P < 0.001) and the best metal artifact reduction was seen with Helical +SEMAR and Volume +SEMAR. The subjective overall preference of CT acquisition type was (1) Helical +SEMAR, (2) Volume +SEMAR, (3) VM DECT 135 keV, (4) VM DECT 120 keV, (5) VM DECT 105 keV, (6) Standard Helical, (7) Standard Volume (P < 0.001). Unblinded objective evaluation performed by one observer showed that VM DECT 120 keV, Helical +SEMAR, and Volume +SEMAR performed similarly and were objectively the best at reducing blooming artifact. Overall, the best metal artifact reduction was obtained with SEMAR, followed by VM DECT. However, VM DECT performance varies with energy level and was associated with decreased image quality in distant tissues and artifactual overcorrection of metal artifacts at high energy levels.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 31 条
  • [1] Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Martin, Simon S.
    Nance, John W.
    Duguay, Taylor M.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Varga-Szemes, Akos
    van Assen, Marly
    Tesche, Christian
    Schoepf, U. Joseph
    [J]. RADIOLOGY, 2019, 293 (02) : 260 - 271
  • [2] Metal artefact reduction in CT imaging of hip prostheses-an evaluation of commercial techniques provided by four vendors
    Andersson, K. M.
    Nowik, P.
    Persliden, J.
    Thunberg, P.
    Norrman, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052)
  • [3] Visual grading evaluation of commercially available metal artefact reduction techniques in hip prosthesis computed tomography
    Andersson, Karin M.
    Norrman, Eva
    Geijer, Hakan
    Krauss, Wolfgang
    Cao, Yang
    Jendeberg, Johan
    Geijer, Mats
    Liden, Mats
    Thunberg, Per
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
  • [4] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [5] Artifacts in CT: Recognition and avoidance
    Barrett, JF
    Keat, N
    [J]. RADIOGRAPHICS, 2004, 24 (06) : 1679 - 1691
  • [6] Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants
    Bolstad, Kirsten
    Flatabo, Silje
    Aadnevik, Daniel
    Dalehaug, Ingvild
    Vetti, Nils
    [J]. ACTA RADIOLOGICA, 2018, 59 (09) : 1110 - 1118
  • [7] Comparison and Combination of Dual-Energy- and Iterative-Based Metal Artefact Reduction on Hip Prosthesis and Dental Implants
    Bongers, Malte N.
    Schabel, Christoph
    Thomas, Christoph
    Raupach, Rainer
    Notohamiprodjo, Mike
    Nikolaou, Konstantin
    Bamberg, Fabian
    [J]. PLOS ONE, 2015, 10 (11):
  • [8] Visibility of Transcondylar Screw Fractures in Standard and Extended Scale Computed Tomography Images
    Brash, Robert
    Labrador, Jose
    Holdsworth, Andrew
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (02) : 128 - 133
  • [9] Radiographic and Computed Tomographic Configuration of Incomplete Proximal Fractures of the Proximal Phalanx in Horses Not Used for Racing
    Bruenisholz, Herve P.
    Hagen, Regine
    Fuerst, Anton E.
    Kuemmerle, Jan M.
    [J]. VETERINARY SURGERY, 2015, 44 (07) : 809 - 815
  • [10] Long-term clinical and radiographic results after lag screw ostheosynthesis of short incomplete proximal sagittal fractures of the proximal phalanx in horses not used for racing
    Bryner, Marco F.
    Hoey, Seamus E.
    Montavon, Stephane
    Furst, Anton E.
    Kummerle, Jan M.
    [J]. VETERINARY SURGERY, 2020, 49 (01) : 88 - 95