A systematic review and meta-analysis of thoracic endovascular aortic repair with the proximal landing zone 0

被引:6
|
作者
Zhu, Longtu [1 ]
Li, Xiaoye [1 ]
Lu, Qingsheng [1 ]
机构
[1] Naval Med Univ, Changhai Hosp, Dept Gen Surg, Div Vasc Surg, Shanghai, Peoples R China
来源
关键词
zone; 0; TEVAR; fenestrated TEVAR; chimney TEVAR; hybrid endovascular aortic repair; endograft; complications after TEVAR; ASCENDING AORTA; HYBRID REPAIR; CLINICAL-OUTCOMES; CHIMNEY TECHNIQUE; 30-DAY MORTALITY; ARCH ANEURYSMS; STENT-GRAFTS; DISSECTION; EXPERIENCE; ENDOGRAFT;
D O I
10.3389/fcvm.2023.1034354
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Thoracic endovascular aortic repair, initially intended for thoracic aortic disease treatment, has extended its application to the proximal zone of the aorta. However, the safety and surgical outcomes of extending the proximal landing zone into the ascending aorta (zone 0) in selected cases remain unknown. Thus, we performed a systematic review and meta-analysis of zone 0 thoracic endovascular aortic repair (TEVAR) to obtain a deeper understanding of its safety, outcomes, and trends over time.Methods A literature search was performed using PubMed, EMBASE, and Web of Science databases in accordance with the preferred reporting items for systematic reviews and meta-analyses guidelines, from January, 1997 to January, 2022. Only studies involving zone 0 TEVAR were included. The retrieved data from the eligible studies included basic study characteristics, 30-day/in-hospital mortality rate, indications, comorbidities, stent grafts, techniques, and complications. Summary effect measures of the primary outcomes were obtained by logarithmically pooling the data with an inverse variance-weighted fixed-effects model.Results Fifty-three studies with 1,013 patients were eligible for analysis. The pooled 30-day/in-hospital mortality rate of zone 0 TEVAR was 7.49%. The rates of post-operative stroke, type Ia endoleak, retrograde type A aortic dissection, and spinal cord ischemia were 8.95, 9.01, 5.72, and 4.12%, respectively.Conclusions Although many novel stent grafts and techniques targeting zone 0 TEVAR are being investigated, a consensus on technique and device selection in zone 0 TEVAR is yet to be established in current practice. Furthermore, the post-operative stroke rate is relatively high, while other complication rates and perioperative death rate are comparable to those of TEVAR for other aortic zones.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The Effect of More Proximal Landing Zone on Stroke and Mortality in Thoracic Endovascular Aortic Repair: A Meta-Analysis
    Ma, Yuchi
    Siddiqui, Mishal S.
    Farhan, Syed A.
    Albuquerque, Francisco C., Jr.
    Larson, Robert
    Levy, Mark M.
    Klein, Katherine M.
    Newton, Daniel H.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : E150 - E150
  • [2] A meta-analysis on the effect of proximal landing zone location on stroke and mortality in thoracic endovascular aortic repair
    Ma, Yuchi
    Siddiqui, Mishal S.
    Farhan, Syed A.
    Albuquerque, Francisco C.
    Larson, Robert A.
    Levy, Mark M.
    Chery, Josue
    Newton, Daniel H.
    JOURNAL OF VASCULAR SURGERY, 2023, 78 (06) : 1559 - +
  • [3] Thoracic Endovascular Aortic Repair in Traumatic Blunt Thoracic Aortic Injury: A Systematic Review & Meta-analysis
    Jubouri, Matti
    Surkhi, Abdelaziz
    D'Oria, Mario
    Bailey, Damian
    Williams, Ian
    Bashir, Mohamad
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [4] The Effect of Proximal Landing Zone on Stroke and Mortality in Thoracic Endovascular Aortic Repair
    Ma, Yuchi
    Siddiqui, Mishal
    Farhan, Syed
    Albuquerque, Francisco
    Larson, Robert
    Levy, Mark
    Chery, Josue
    Newton., Daniel
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (03) : E18 - E18
  • [5] The proximal landing zone in endovascular repair of the thoracic aorta
    Tse, LW
    MacKenzie, KS
    Montreuil, B
    Obrand, DI
    Steinmetz, OK
    ANNALS OF VASCULAR SURGERY, 2004, 18 (02) : 178 - 185
  • [6] Landing in zone 0: Is ascending thoracic endovascular aortic repair ready for takeoff?
    Czerny, Martin
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (04): : 1390 - 1390
  • [7] The effect of obesity on the outcome of thoracic endovascular aortic repair: a systematic review and meta-analysis
    Li, Jiajun
    Zhang, Yucong
    Huang, Haijun
    Zhou, Yongzhi
    Wang, Jing
    Hu, Min
    PEERJ, 2024, 12
  • [8] The effect of obesity on the outcome of thoracic endovascular aortic repair: a systematic review and meta-analysis
    Li, Jiajun
    Zhang, Yucong
    Huang, Haijun
    Zhou, Yongzhi
    Wang, Jing
    Hu, Min
    PEERJ, 2024, 12
  • [9] Strategies for managing the insufficiency of the proximal landing zone during endovascular thoracic aortic repair
    Fu, WG
    Dong, ZH
    Wang, YQ
    Guo, DQ
    Xu, X
    Chen, B
    Jiang, JH
    Yang, J
    Shi, ZY
    CHINESE MEDICAL JOURNAL, 2005, 118 (13) : 1066 - 1071