An evaluation of the use of DirectSPR images for proton planning in the RayStation treatment planning software

被引:6
作者
Sarkar, Vikren [1 ,2 ]
Paxton, Adam [1 ]
Su, Fanchi [1 ]
Price, Ryan [1 ]
Nelson, Geoff [1 ]
Szegedi, Martin [1 ]
St James, Sara [1 ]
Salter, Bill J. [1 ]
机构
[1] Univ Utah, Salt Lake City, UT USA
[2] Univ Utah, Dept Radiat Oncol, 1950 Circle Hope, Salt Lake City, UT 84112 USA
关键词
dual energy CT; proton therapy; stopping power ratio; treatment planning; ENERGY COMPUTED-TOMOGRAPHY; DOSE CALCULATIONS; PREDICTION;
D O I
10.1002/acm2.13900
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An important source of uncertainty in proton therapy treatment planning is the assignment of stopping-power ratio (SPR) from CT data. A commercial product is now available that creates an SPR map directly from dual-energy CT (DECT). This paper investigates the use of this new product in proton treatment planning and compares the results to the current method of assigning SPR based on a single-energy CT (SECT). Two tissue surrogate phantoms were CT scanned using both techniques. The SPRs derived from single-energy CT and by DirectSPR (TM) were compared to measured values. SECT-based values agreed with measurements within 4% except for low density lung and high density bone, which differed by 13% and 8%, respectively. DirectSPR (TM) values were within 2% of measured values for all tissues studied. Both methods were also applied to scanned containers of three types of animal tissue, and the expected range of protons of two different energies was calculated in the treatment planning system and compared to the range measured using a multi-layer ion chamber. The average difference between range measurements and calculations based on SPR maps from dual- and single-energy CT, respectively, was 0.1 mm (0.07%) versus 2.2 mm (1.5%). Finally, a phantom was created using a layer of various tissue surrogate plugs on top of a 2D ion chamber array. Dose measurements on this array were compared to predictions using both single- and dual-energy CTs and SPR maps. While standard gamma pass rates for predictions based on DECT-derived SPR maps were slightly higher than those based on single-energy CT, the differences were generally modest for this measurement setup. This study showed that SPR maps created by the commercial product from dual-energy CT can successfully be used in RayStation to generate proton dose distributions and that these predictions agree well with measurements.
引用
收藏
页数:8
相关论文
共 18 条
[1]  
Bethe H., 1953, EXPT NUCL PHYS
[2]  
Gajewski J., 2021, MATLAB CENTRAL FILE
[3]   Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy [J].
Huang, Sheng ;
Souris, Kevin ;
Li, Siyang ;
Kang, Minglei ;
Montero, Ana Maria Barragan ;
Janssens, Guillaume ;
Lin, Alexander ;
Garver, Elizabeth ;
Ainsley, Christopher ;
Taylor, Paige ;
Xiao, Ying ;
Lin, Liyong .
MEDICAL PHYSICS, 2018, 45 (12) :5631-5642
[4]   Validation of the proton range accuracy and optimization of CT calibration curves utilizing range probing [J].
Meijers, A. ;
Free, J. ;
Wagenaar, D. ;
Deffet, S. ;
Knopf, A. C. ;
Langendijk, J. A. ;
Both, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (03)
[5]   Experimental verification of stopping-power prediction from single- and dual-energy computed tomography in biological tissues [J].
Moehler, Christian ;
Russ, Tom ;
Wohlfahrt, Patrick ;
Elter, Alina ;
Runz, Armin ;
Richter, Christian ;
Greilich, Steffen .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
[6]   Initial Validation of Proton Dose Calculations on SPR Images from DECT in Treatment Planning System [J].
Mossahebi, Sina ;
Sabouri, Pouya ;
Chen, Haijian ;
Mundis, Michelle ;
O'Neil, Matthew ;
Maggi, Paul ;
Polf, Jerimy C. .
INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2020, 7 (02) :51-61
[8]   Material assignment for proton range prediction in Monte Carlo patient simulations using stopping-power datasets [J].
Permatasari, Felicia Fibiani ;
Eulitz, Jan ;
Richter, Christian ;
Wohlfahrt, Patrick ;
Luehr, Armin .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18)
[9]   Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction [J].
Peters, Nils ;
Wohlfahrt, Patrick ;
Hofmann, Christian ;
Moehler, Christian ;
Menkel, Stefan ;
Tschiche, Maria ;
Krause, Mechthild ;
Troost, Esther G. C. ;
Enghardt, Wolfgang ;
Richter, Christian .
RADIOTHERAPY AND ONCOLOGY, 2022, 166 :71-78
[10]  
RaySearch Laboratories AB, 2021, RAYST 11A REF MAN