Theoretical calculation of response sensitivity of CsI photocathode of soft X-ray streak camera

被引:0
|
作者
He, Xiao-An [1 ]
Yang, Jia-Min [1 ]
Li, Yu-Kun [1 ]
Li, Jin [1 ]
Xiong, Gang [1 ,2 ]
机构
[1] Chinese Acad Sci, Laser Fus Res Ctr, Mianyang 621900, Peoples R China
[2] Fudan Univ, Inst Modern Phys, Key Lab Nucl Phys & Ion Beam Applicat MOE, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
secondaryelectron; CsIphotocathode; X-ray; responsesensitivity; SECONDARY-ELECTRON EMISSION;
D O I
10.7498/aps.72.20231043
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The response sensitivity of CsI photocathode is an important parameter for the quantitative diagnosis of Xray spectroscopy by soft X-ray streak camera, and its theoretical calculation has important guiding significance. The current theoretical analytical models are based on the one-dimensional random walking model of secondary electrons generated by thin film photocathodes, including the Henke model under the condition of normal incidence of X-rays and energy greater than 1 keV, and the Fraser model under variable angle incidence and photocathode thickness greater than 100 nm, which have certain limitations. In this paper, the basic expression of the probability of secondary electron transmission is introduced, and the general expression of the response sensitivity of CsI photocathode is deduced, which varies with X-ray energy E, photocathode thickness t, and angle theta between X-ray and cathode surface in a larger parameter range (X-ray energy 0.1-10 keV, photocathode thickness 10-200 nm). Finally, the theoretical calculation results of this paper are discussed by comparing it with those from the Henke model, Fraser model, literature data and experimental data on Beijing synchrotron radiation facility, which verifies the accuracy and universality of the computational model, and a theoretical reference is provided for optimally designing the CsI photocathode in high-time-resolution spectrometric quantitative measurement.
引用
收藏
页数:9
相关论文
共 20 条
  • [1] MONTE-CARLO SIMULATIONS OF SECONDARY-ELECTRON EMISSION FROM CSI, INDUCED BY 1-10 KEV X-RAYS AND ELECTRONS
    AKKERMAN, A
    GIBREKHTERMAN, A
    BRESKIN, A
    CHECHIK, R
    [J]. JOURNAL OF APPLIED PHYSICS, 1992, 72 (11) : 5429 - 5436
  • [2] Observation of early shell-dopant mix in OMEGA direct-drive implosions and comparisons with radiation-hydrodynamic simulations
    Baumgaertel, J. A.
    Bradley, P. A.
    Hsu, S. C.
    Cobble, J. A.
    Hakel, P.
    Tregillis, I. L.
    Krasheninnikova, N. S.
    Murphy, T. J.
    Schmitt, M. J.
    Shah, R. C.
    Obrey, K. D.
    Batha, S.
    Johns, H.
    Joshi, T.
    Mayes, D.
    Mancini, R. C.
    Nagayama, T.
    [J]. PHYSICS OF PLASMAS, 2014, 21 (05)
  • [3] An improved model for ultraviolet- and x-ray-induced electron emission from CsI
    Boutboul, T
    Akkerman, A
    Gibrekhterman, A
    Breskin, A
    Chechik, R
    [J]. JOURNAL OF APPLIED PHYSICS, 1999, 86 (10) : 5841 - 5849
  • [4] Chen H, 2017, Phys. Plasmas, V24
  • [5] DIAGNOSIS OF PUSHER-FUEL MIX IN INDIRECTLY DRIVEN NOVA IMPLOSIONS
    DITTRICH, TR
    HAMMEL, BA
    KEANE, CJ
    MCEACHERN, R
    TURNER, RE
    HAAN, SW
    SUTER, LJ
    [J]. PHYSICAL REVIEW LETTERS, 1994, 73 (17) : 2324 - 2327
  • [6] THE CHARACTERIZATION OF SOFT-X-RAY TRANSMISSION PHOTOCATHODES
    FRASER, GW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 228 (2-3): : 532 - 540
  • [7] THE CHARACTERIZATION OF SOFT-X-RAY PHOTO-CATHODES IN THE WAVELENGTH BAND 1-300 A .1. LEAD GLASS, LITHIUM-FLUORIDE AND MAGNESIUM FLUORIDE
    FRASER, GW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (1-2): : 251 - 263
  • [8] CHARACTERISTICS OF SECONDARY-ELECTRON EMISSION FROM CSL INDUCED BY X-RAYS WITH ENERGIES UP TO 100-KEV
    GIBREKHTERMAN, A
    AKKERMAN, A
    BRESKIN, A
    CHECHIK, R
    [J]. JOURNAL OF APPLIED PHYSICS, 1993, 74 (12) : 7506 - 7509
  • [9] THE CHARACTERIZATION OF X-RAY PHOTO-CATHODES IN THE 0.1-10-KEV PHOTON ENERGY REGION
    HENKE, BL
    KNAUER, JP
    PREMARATNE, K
    [J]. JOURNAL OF APPLIED PHYSICS, 1981, 52 (03) : 1509 - 1520
  • [10] A time-resolved three-channel soft X-ray spectrometer
    Hu Xin
    Jiang Shao-En
    Cui Yan-Li
    Huang Yi-Xiang
    Ding Yong-Kun
    Liu Zhong-Li
    Yi Rong-Qing
    Li Chao-Guang
    Zhang Jing-He
    Zhang Hua-Quan
    [J]. ACTA PHYSICA SINICA, 2007, 56 (03) : 1447 - 1451