Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 43 条
  • [41] Influence of dosimeter depth on estimating patient's eye lens dose in head computed tomography: A measurement and Monte Carlo simulation study
    Hirosawa, Ayaka
    Matsubara, Kosuke
    Fukuda, Atsushi
    Morioka, Yusuke
    Kitagawa, Masayasu
    Ogawa, Yoshinori
    RADIATION MEASUREMENTS, 2023, 166
  • [42] Effekt von Strahlenschutzvisieren auf die Augenlinsendosis bei der UreterorenoskopieEffect of X-ray protective visors on the eye lens dose during ureteroscopy
    G. Zöller
    V. Konstanz
    J. Brönner
    H. Hödlmoser
    Der Urologe, 2020, 59 (10): : 1231 - 1236
  • [43] Evaluation of the dose reduction effect of crystalline lens exposure in cone-beam computed tomography with bismuth eye shield for image-guided radiation therapy: An anthropomorphic phantom study
    Yoshida, Tatsuya
    Sasaki, Koji
    Kawasaki, Yoshiyuki
    Hayakawa, Tomoki
    Kawadai, Toshiyuki
    Shibasaki, Takako
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,