Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 43 条
  • [31] Risk of Radiation-Induced Cataracts: Investigation of Radiation Exposure to the Eye Lens During Endourologic Procedures
    Hartmann, Josefin
    Distler, Florian
    Baumueller, Martin
    Guni, Ewald
    Pahernik, Sascha
    Wucherer, Michael
    JOURNAL OF ENDOUROLOGY, 2018, 32 (10) : 897 - 903
  • [32] DIRECT MEASUREMENTS OF SKIN, EYE LENS AND THYROID DOSE DURING PEDIATRIC BRAIN CT EXAMINATIONS
    Ploussi, Agapi
    Stathopoulos, Ioannis
    Syrgiamiotis, Vasileios
    Makri, Triantafillia
    Hatzigiorgi, Christiana
    Platoni, Kalliopi
    Carinou, Eleftheria
    Efstathopoulos, Efstathios P.
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 199 - 205
  • [33] Influence of safety glasses, body height and magnification on the occupational eye lens dose during pelvic vascular interventions: a phantom study
    Alexander Gangl
    Hannes Alexander Deutschmann
    Rupert Horst Portugaller
    Georg Stücklschweiger
    European Radiology, 2022, 32 : 1688 - 1696
  • [34] Evaluation of factors influencing eye lens radiation dose while using radiation protection glasses in interventional radiology: A phantom study
    Imai, Shinya
    Yamahata, Asuka
    Gotanda, Tatsuhiro
    Akahane, Manabu
    Kawaji, Yasuyuki
    Akagawa, Takuya
    Yatake, Hidetoshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [35] Evaluation of calibration factor of OSLD toward eye lens exposure dose measurement of medical staff during IVR
    Asahara, Takashi
    Hayashi, Hiroaki
    Goto, Sota
    Kimoto, Natsumi
    Takegami, Kazuki
    Maeda, Tatsuya
    Kanazawa, Yuki
    Okazaki, Tohru
    Hashizume, Takuya
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 263 - 271
  • [36] Assessment of Eye Lens Dose Reduction When Using Lateral Lead Shields on the Patient's Head during Neurointerventional Fluoroscopic Procedures and Cone-beam Computed Tomography (CBCT) Scans
    Xiong, Zhenyu
    Rudin, Stephen
    Bednarek, Daniel R.
    HEALTH PHYSICS, 2020, 119 (03): : 289 - 296
  • [37] Patient radiation dose during diagnostic and interventional cardiology procedures A study in a tertiary hospital
    Anim-Sampong, Samuel
    Antwi, William Kwadwo
    Adomako, John Bright
    Botwe, Benard Ohene
    Sarkodie, Benjamin Dabo
    Brakohiapa, Edmund K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (02) : 298 - 305
  • [38] Patient dose during interventional neuroradiology procedures: Results from a multi-center study
    Kien, N.
    Rehel, J. -L.
    Etard, C.
    Aubert, B.
    JOURNAL DE RADIOLOGIE, 2011, 92 (12): : 1101 - 1112
  • [39] Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head: A Monte Carlo study
    Perisinakis, K
    Raissaki, M
    Tzedakis, A
    Theocharopoulos, N
    Damilakis, J
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2005, 32 (04) : 1024 - 1030
  • [40] Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study
    Morishima, Yoshiaki
    Chida, Koichi
    Chiba, Hiroo
    Kumagai, Koji
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (06) : 2745 - 2751