Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 43 条
  • [21] A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
    Farah, J.
    Struelens, L.
    Dabin, J.
    Koukorava, C.
    Donadille, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 561 - 569
  • [22] Radiation dose and risk to the lens of the eye during CT examinations of the brain
    Poon, Rebekah
    Badawy, Mohamed K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (06) : 786 - 794
  • [23] Influence of safety glasses, body height and magnification on the occupational eye lens dose during pelvic vascular interventions: a phantom study
    Gangl, Alexander
    Deutschmann, Hannes Alexander
    Portugaller, Rupert Horst
    Stuecklschweiger, Georg
    EUROPEAN RADIOLOGY, 2022, 32 (03) : 1688 - 1696
  • [24] Effectiveness of Breast and Eye Shielding During Cervical Spine Radiography: An Experimental Study
    Elshami, Wiam
    Abuzaid, Mohamed M.
    Tekin, H. O.
    RISK MANAGEMENT AND HEALTHCARE POLICY, 2020, 13 : 697 - 704
  • [25] Are orthopedic surgeons exposed to excessive eye irradiation? A prospective study of lens irradiation in orthopedics and traumatology
    Cuenca, Celine
    Mention, Pierre-Jean
    Vergnenegre, Guillaume
    Matthieu, Pierre-Alain
    Charissoux, Jean-Louis
    Marcheix, Pierre-Sylvain
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (03) : 569 - 572
  • [26] A study on the dose distributions near the eye lens and the legs. Part 2-Interventional radiology
    Domienik, J.
    Rusicka, D.
    Szubert, W.
    RADIATION MEASUREMENTS, 2013, 51-52 : 62 - 66
  • [27] Effect of X-ray protective visors on the eye lens dose during ureteroscopy
    Zoeller, G.
    Konstanz, V
    Broenner, J.
    Hoedlmoser, H.
    UROLOGE, 2020, 59 (10): : 1231 - 1236
  • [28] Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose
    S. Harrison Farber
    Gautam Nayar
    Rupen Desai
    Elizabeth W. Reiser
    Sarah A. Byrd
    Deborah Chi
    Cary Idler
    Robert E. Isaacs
    European Spine Journal, 2018, 27 : 1911 - 1917
  • [29] Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose
    Farber, S. Harrison
    Nayar, Gautam
    Desai, Rupen
    Reiser, Elizabeth W.
    Byrd, Sarah A.
    Chi, Deborah
    Idler, Cary
    Isaacs, Robert E.
    EUROPEAN SPINE JOURNAL, 2018, 27 (08) : 1911 - 1917
  • [30] Assessment of Occupational Exposure to Eye Lens Dosimetry for Interventional Radiology Workers in China during 2017-2019
    Li, Mengxue
    Fan, Shengnan
    Zhang, Xianpeng
    Hao, Shuxia
    Zhao, Yu
    Deng, Jun
    Sun, Quanfu
    HEALTH PHYSICS, 2022, 123 (03): : 229 - 237