Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 43 条
  • [11] EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE
    Ciraj-Bjelac, Olivera
    Antic, Vojislav
    Selakovic, Jovana
    Bozovic, Predrag
    Arandjic, Danijela
    Pavlovic, Sinisa
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 475 - 482
  • [12] Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian Hospital
    Wong, Jeannie Hsiu Ding
    Anem, Lydia Esther Andrew
    Tan, Suzet
    Tan, Sock Keow
    Ng, Kwan Hoong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 47 - 51
  • [13] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284
  • [14] Radiation dose to the operator during fluoroscopically guided spine procedures
    Luca Roccatagliata
    Stefano Presilla
    Emanuele Pravatà
    Alessandro Cianfoni
    Neuroradiology, 2017, 59 : 885 - 892
  • [15] Radiation dose to the operator during fluoroscopically guided spine procedures
    Roccatagliata, Luca
    Presilla, Stefano
    Pravata, Emanuele
    Cianfoni, Alessandro
    NEURORADIOLOGY, 2017, 59 (09) : 885 - 892
  • [16] Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study
    Yamada, Ayumi
    Haga, Yoshihiro
    Sota, Masahiro
    Abe, Mitsuya
    Kaga, Yuji
    Inaba, Yohei
    Suzuki, Masatoshi
    Tada, Norio
    Zuguchi, Masayuki
    Chida, Koichi
    DIAGNOSTICS, 2023, 13 (18)
  • [17] Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures
    Kong, Y.
    Struelens, L.
    Vanhavere, F.
    Vargas, C. S.
    Schoonjans, W.
    Zhuo, W. H.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 181 - 187
  • [18] Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head
    Xiong, Zhenyu
    Vijayan, Sarath
    Rana, Vijay
    Jain, Amit
    Rudin, Stephen
    Bednarek, Daniel R.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [19] A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures
    Wilson-Stewart, Kelly S.
    Fontanarosa, Davide
    Malacova, Eva
    Trapp, Jamie V.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [20] Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose
    Ciraj-Bjelac, Olivera
    Carinou, Eleftheria
    Ferrari, Paolo
    Gingaume, Merce
    Merce, Marta Sans
    O'Connor, Una
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (11) : 1347 - 1353