Eye lens dose in spine surgeons during myelography procedures: a dosimetry study

被引:0
作者
Nagamoto, Keisuke [1 ]
Kawachino, Tomonori [1 ]
Suetsugu, Yoshiki [1 ]
Saruwatari, Hiromi [1 ]
Nihei, Shun-ichi [2 ]
Kunugita, Naoki [3 ]
机构
[1] Hosp Univ Occupat & Environm Hlth, Dept Radiol, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Emergency & Intens Care Med, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
[3] Univ Occupat & Environm Hlth, Dept Occupat & Community Hlth, Nursing Sch Hlth Sci, 1-1 Iseigaoka,Yahatanishi Ku, Fukuoka, Japan
关键词
3 mm dose equivalent; Hp(3); lens dose; myelography; spine surgeons; radio-photoluminescence glass dosimeters; x-ray tube system; INTERVENTIONAL RADIOLOGY; RADIATION-EXPOSURE; FLUOROSCOPY; TRIAL; CT;
D O I
10.1088/1361-6498/ad0b3a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83) mu Sv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31) mu Sv mGy-1 for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.
引用
收藏
页数:10
相关论文
共 43 条
  • [1] Eye lens dosimetry for interventional procedures - Relation between the absorbed dose to the lens and dose at measurement positions
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1248 - 1251
  • [2] Dosimetry of Occupational Eye Lens Dose Using a Novel Direct Eye Dosimeter, DOSIRIS, during Interventional Radiology Procedures
    Hirakawa, Masakazu
    Nakatake, Hiroshi
    Tsuruta, Satoru
    Matsuura, Shuji
    Motomura, Yuushi
    Hiraki, Yoshiki
    Mimori, Koshi
    Ishigami, Kousei
    INTERVENTIONAL RADIOLOGY, 2022, 7 (02) : 40 - 43
  • [3] Real-time eye lens dose monitoring during cerebral angiography procedures
    Safari, M. J.
    Wong, J. H. D.
    Kadir, K. A. A.
    Thorpe, N. K.
    Cutajar, D. L.
    Petasecca, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    Ng, K. H.
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 79 - 86
  • [4] EYE LENS DOSIMETRY FOR FLUOROSCOPICALLY GUIDED CLINICAL PROCEDURES: PRACTICAL APPROACHES TO PROTECTION AND DOSE MONITORING
    Martin, Colin J.
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 286 - 291
  • [5] DOSES TO OPERATORS DURING INTERVENTIONAL RADIOLOGY PROCEDURES: FOCUS ON EYE LENS AND EXTREMITY DOSIMETRY
    Koukorava, C.
    Carinou, E.
    Simantirakis, G.
    Vrachliotis, T. G.
    Archontakis, E.
    Tierris, C.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 482 - 486
  • [6] Dose estimation of eye lens for interventional procedures in diagnosis
    Liu, Yu-Rong
    Huang, Chia-Yu
    Hsu, Ching-Han
    Hsu, Fang-Yuh
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 247 - 251
  • [7] DOSIMETRY FOR THE LENS OF THE EYE, APPLICATIONS FOR MEDICAL STAFF INVOLVED IN INTERVENTIONAL PROCEDURES
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 105 - 108
  • [8] Real-time eye lens dose monitoring during cerebral angiography procedures
    M. J. Safari
    J. H. D. Wong
    K. A. A. Kadir
    N. K. Thorpe
    D. L. Cutajar
    M. Petasecca
    M. L. F. Lerch
    A. B. Rosenfeld
    K. H. Ng
    European Radiology, 2016, 26 : 79 - 86
  • [9] ASSESSMENT OF OCCUPATIONAL EYE LENS EXPOSURE DURING IMAGE-GUIDED ORTHOPEDIC PROCEDURES
    Samac, Jelena J.
    Bozovic, Predrag M.
    Petrovic, Jelena S. Stankovi
    Petrovic, Borislava
    Vranjes, Miodrag N.
    Rasovic, Predrag V.
    Obradovic, Mirko M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2023, 38 (03) : 202 - 207
  • [10] Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures
    Struelens, L.
    Schoonjans, W.
    Schils, F.
    De Smedt, K.
    Vanhavere, F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 635 - 645