共 30 条
Finite element analysis of low-profile reconstruction plates for atrophic mandibles: a comparison of novel 3D grid and conventional plate designs
被引:1
作者:
Guerra, Raphael Capelli
[1
]
Borim Pulino, Bianca de Fatima
[2
]
Salomao Junior, Vitor Floriano
[3
]
Pereira, Rodrigo dos Santos
[4
]
Thieringer, Florian M.
[5
]
Sacco, Roberto
[6
]
Sader, Robert
[7
]
Vieira, Eduardo Hochuli
[8
]
机构:
[1] Sao Paulo State Univ Araraquara UNESP, Sao Paulo Metodista Univ, Hosp Sirio Libanes, Res & Educ Inst,DASA Leforte Group, Sao Paulo, Brazil
[2] Sao Paulo State Univ Aracatuba, Sao Paulo Metodista Univ, Hosp Sirio Libanes, Res & Educ Inst,DASA Leforte Group, Praca Francisco Manuel, 72, BR-01541020 Sao Paulo, Brazil
[3] Univ Ctr, Claretian, Rio Claro, Brazil
[4] UNIGRANRIO, Rio De Janeiro, Brazil
[5] Univ Hosp Basel, Basel, Switzerland
[6] Univ Manchester, Sch Med Sci, Oral Surg Dept, Div Dent, London, England
[7] Goethe Univ Frankfurt, Klinikum Johann Wolfgang Goethe, Frankfurt, Hessen, Germany
[8] Sao Paulo State Univ, Hosp Sirio Libanes, Res & Educ Inst, DASA Leforte Group, Araraquara, Brazil
来源:
ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG
|
2024年
/
28卷
/
02期
关键词:
Mandible;
Mandible fixation technique;
Edentulous mandible;
Finite element analysis;
Mandibular reconstructions;
MANDIBULAR RECONSTRUCTION;
BIOMECHANICAL ANALYSIS;
FIXATION;
ADVANCEMENT;
MANAGEMENT;
FRACTURES;
STABILITY;
IMPLANTS;
MODEL;
D O I:
10.1007/s10006-023-01173-3
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
ObjectivesThis study aimed to compare the reconstruction with type 2.4 and three-dimensional (3D) grid plates relating the areas of weakness to anatomical regions of force incidence in atrophic mandibles with and without segmentation using finite element analysis (FEA).Materials and methodsStrength and force quality in the mandible were also determined. The atrophic mandible models with and without segmentation were divided into four groups, and the behavior of each plate was analyzed using finite element analysis. In the atrophic mandible without segmentation using the type 2.4 reconstruction plate, the highest stress concentration in the plate was observed in the posterior region of the mandibular body and in the grid type 3D reconstruction plate was observed in the mandibular angle.ResultsIn the segmented atrophic mandible with the 2.4 reconstruction plate, higher stress concentration was observed in the mandibular segment defect. Analysis of the 3D grid-like reconstruction plate revealed that the geometry of the plate conferred greater stiffness to the assembly, as the most significant stress concentration was observed at the mandibular angle.ConclusionThe width of the plate design may influence the strength, not the thickness.