T2-weighted MRI and reduced-FOV diffusion-weighted imaging of the human pancreas at 5 T: A comparison study with 3 T

被引:5
作者
Zheng, Liyun [1 ,2 ,3 ]
Yang, Chun [1 ,2 ]
Liang, Liang [1 ,2 ]
Rao, Shengxiang [1 ,2 ]
Dai, Yongming [4 ]
Zeng, Mengsu [1 ,2 ]
机构
[1] Shanghai Inst Med Imaging, Shanghai, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[3] Shenzhen United Imaging Res Inst Innovat Med Equi, Shenzhen, Peoples R China
[4] United Imaging Healthcare, Cent Res Inst, MR Collaborat, 2258 Chengbei Rd, Shanghai 201807, Peoples R China
基金
中国国家自然科学基金;
关键词
diffusion-weighted imaging; high-field MRI; pancreatic imaging; reduced field-of-view; 5; 0; T; MAGNETIC-RESONANCE; LESION DETECTION; BREATH-HOLD; NORMAL HEAD; 3.0; TESLA; LIVER; CANCER; BODY; DWI; REPRODUCIBILITY;
D O I
10.1002/mp.15970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to explore the feasibility of pancreatic imaging at 5 T and evaluate the practical improvement of T2-weighted MRI and diffusion-weighted imaging (DWI) at 5 T as compared with 3 T. Methods Eighteen healthy subjects were recruited for this pilot study. MRI examinations were performed using 3 and 5 T scanners. MRI sequences included T2-weighted fast spin-echo and DWI with reduced field-of-view. Subjective image analysis using a four-point Likert scale was performed by two experienced radiologists. The SNR, contrast ratio, and apparent diffusion coefficient (ADC) were measured in the pancreatic head, body, and tail. The coefficient of variation (CV) of the ADC was calculated. A series of paired Wilcoxon tests were used to compare the subjective image quality, mean ADC value, and CV of ADC between the 3 and 5 T measurements. p For T2-weighted images, there were no significant differences in image quality ratings between 3 and 5 T. On DWI images (b = 0 and 800 s/mm(2)), the image quality ratings were significantly higher at 5 T than at 3 T. The SNRs of both T2-weighted and DWI images were significantly higher at 5 T. There was no significant difference in the mean ADC values and CV of ADC between 3 and 5 T. Conclusion This initial study proved that 5 T MRI can be used to acquire pancreatic images with higher SNR and sufficient image quality compared to 3 T MRI.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 44 条
  • [1] Abdominal MR Imaging at 3.0 T
    Akisik, Fatih M.
    Sandrasegaran, Kumaresan
    Aisen, Alex M.
    Lin, Chen
    Lall, Chandana
    [J]. RADIOGRAPHICS, 2007, 27 (05) : 1433 - 1444
  • [2] Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen
    Braithwaite, Adam C.
    Dale, Brian M.
    Boll, Daniel T.
    Merkle, Elmar M.
    [J]. RADIOLOGY, 2009, 250 (02) : 459 - 465
  • [3] Magnetic resonance imaging of the pancreas at 3.0 tesla - Qualitative and quantitative comparison with 7.5 tesla
    Edelman, RR
    Salanitri, G
    Brand, R
    Dunkle, E
    Ragin, A
    Li, W
    Mehta, W
    Berlin, J
    Newmark, G
    Gore, R
    Patel, B
    Carillo, A
    Vu, A
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 175 - 180
  • [4] Pancreatic Diffusion-Weighted Imaging (DWI): Comparison Between Mass-Forming Focal Pancreatitis (FP), Pancreatic Cancer (PC), and Normal Pancreas
    Fattahi, Rana
    Balci, N. Cem
    Perman, William H.
    Hsueh, Eddy C.
    Alkaade, Samer
    Havlioglu, Necat
    Burton, Frank R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 350 - 356
  • [5] Qualitative and Quantitative Comparison of Respiratory Triggered Reduced Field-of-View (FOV) Versus Full FOV Diffusion Weighted Imaging (DWI) in Pancreatic Pathologies
    Harder, Felix N.
    Kamal, Omar
    Kaissis, Georgios A.
    Heid, Irina
    Lohoefer, Fabian K.
    McTavish, Sean
    Van, Anh T.
    Katemann, Christoph
    Peeters, Johannes M.
    Karampinos, Dimitrios C.
    Makowski, Marcus R.
    Braren, Rickmer F.
    [J]. ACADEMIC RADIOLOGY, 2021, 28 : S234 - S243
  • [6] Diffusion-weighted imaging of the healthy pancreas: ADC values are age and gender dependent
    Herrmann, Jochen
    Schoennagel, Bjoern P.
    Roesch, Magdalena
    Busch, Jasmin D.
    Derlin, Thorsten
    Doh, Laura K.
    Petersen, Kay U.
    Graessner, Joachim
    Adam, Gerhard
    Habermann, Christian R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 886 - 891
  • [7] Preliminary investigation of whole-pancreas 3D histogram ADC metrics for predicting progression of acute pancreatitis
    Iranmahboob, Amir K.
    Kierans, Andrea S.
    Huang, Chenchan
    Ream, Justin M.
    Rosenkrantz, Andrew B.
    [J]. CLINICAL IMAGING, 2017, 42 : 172 - 177
  • [8] Juras Vladimir, 2019, Top Magn Reson Imaging, V28, P125, DOI 10.1097/RMR.0000000000000205
  • [9] Focal hepatic lesion detection: Comparison of four fat-suppressed T2-weighted MR imaging pulse sequences
    Kanematsu, M
    Hoshi, H
    Itoh, K
    Murakami, T
    Hori, M
    Kondo, H
    Yokoyama, R
    Nakamura, H
    [J]. RADIOLOGY, 1999, 211 (02) : 363 - 371
  • [10] Kasban H., 2015, Int. J. Inf. Sci. Intell. Syst, V4, P37