Complementary Role of CEUS and CT/MR LI-RADS for Diagnosis of Recurrent HCC

被引:10
作者
Cheng, Mei-Qing [1 ]
Huang, Hui [1 ]
Ruan, Si-Min [1 ]
Xu, Ping [2 ]
Tong, Wen-Juan [1 ]
He, Dan-Ni [3 ]
Huang, Yang [1 ]
Lin, Man-Xia [1 ]
Lu, Ming-De [1 ,4 ]
Kuang, Ming [1 ,4 ]
Wang, Wei [1 ]
Wu, Shao-Hong [1 ]
Chen, Li-Da [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Guangzhou 510080, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Radiol, Guangzhou 510080, Peoples R China
[3] Sun Yat Sen Univ, Dept Med Ultrason, Affiliated Hosp 7, Shenzhen 518107, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Hepatobiliary Surg, Guangzhou 510080, Peoples R China
关键词
hepatocellular carcinoma; ultrasonography; computed tomography; magnetic resonance imaging; contrast agent; CONTRAST-ENHANCED ULTRASOUND; HEPATOCELLULAR-CARCINOMA; LIVER; SURVEILLANCE; SONOGRAPHY; CIRRHOSIS;
D O I
10.3390/cancers15245743
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The diagnostic performance of LI-RADS on CEUS and CT/MRI for characterizing primary HCC has been widely evaluated, but their diagnostic performance on recurrent HCC has not yet. Previous studies that used the same diagnostic criteria for the diagnosis of recurrent HCC proved inadequate, as only a subset (approximately 55-80%) of recurrent HCC cases exhibited the typical imaging features observed in primary HCC on contrast-enhanced CT or MRI. Consequently, this study embarked on an investigation to establish the optimal diagnostic algorithms for recurrent HCC using CEUS, CT, and MRI, and compared the diagnostic performance of CEUS and CT/MRI LI-RADS for recurrent HCC. The results indicated that LR-4/5/M criteria were optimal for CEUS and CT, while LR-5/M criteria were suitable for MRI. CEUS demonstrated better diagnostic performance than CT, while was comparable to MRI. Further, this study analyzed factors affecting the accurate characterization and detection of recurrent HCC on CEUS. Depth and visualization score C were found to hinder accurate characterization, and lesions in US blind spots with visualization score C posed challenges for detection.Purpose: We retrospectively compared the diagnostic performance of contrast-enhanced ultrasonography (CEUS) and contrast-enhanced computer tomography-magnetic resonance imaging (CT/MRI) for recurrent hepatocellular carcinoma (HCC) after curative treatment. Materials and methods: After curative treatment with 421 ultrasound (US) detected lesions, 303 HCC patients underwent both CEUS and CT/MRI. Each lesion was assigned a Liver Imaging Reporting and Data System (LI-RADS) category according to CEUS and CT/MRI LI-RADS. Receiver-operating characteristic (ROC) curves were computed to determine the optimal diagnosis algorithms for CEUS, CT and MRI. The diagnostic accuracy, sensitivity, specificity, and area under the curve (AUC) were compared between CEUS and CT/MRI. Results: Among the 421 lesions, 218 were diagnosed as recurrent HCC, whereas 203 lesions were diagnosed as benign. In recurrent HCC, CEUS detected more arterial hyperenhancement (APHE) and washout than CT and more APHE than MRI. CEUS yielded better diagnostic performance than CT (AUC: 0.981 vs. 0.958) (p = 0.024) comparable diagnostic performance to MRI (AUC: 0.952 vs. 0.933) (p > 0.05) when using their optimal diagnostic criteria. CEUS missed 12 recurrent HCCs, CT missed one, and MRI missed none. The detection rate of recurrent HCC on CEUS (94.8%, 218/230) was lower than that on CT/MRI (99.6%, 259/260) (p = 0.001). Lesions located on the US blind spots and visualization score C would hinder the ability of CEUS to detect recurrent HCC. Conclusion: CEUS demonstrated excellent diagnostic performance but an inferior detection rate for recurrent HCC. CEUS and CT/MRI played a complementary role in the detection and characterization of recurrent HCC.
引用
收藏
页数:13
相关论文
共 27 条
[1]  
American College of Radiology, 2018, CT/MRI liver imaging reporting and data system v2018 core
[2]  
American College of Radiology, Liver Reporting & Data System
[3]   Contrast-enhanced US of the Liver and Kidney: A Problem-solving Modality [J].
Atri, Mostafa ;
Jang, Hyun-Jung ;
Kim, Tae Kyoung ;
Khalili, Korosh .
RADIOLOGY, 2022, 303 (01) :11-25
[4]   A new proposal for secondary surveillance following potentially curative therapy of HCC: alternating MRI and CEUS [J].
Bansal, Sanjay ;
Lu, Fangshi ;
Frehlich, Levi ;
Wong, Jason K. ;
Burak, Kelly W. ;
Wilson, Stephanie R. .
ABDOMINAL RADIOLOGY, 2022, 47 (02) :618-629
[5]  
European Assoc Study Liver, 2018, J HEPATOL, V69, P182, DOI 10.1016/j.jhep.2018.03.019
[6]   Hepatocellular carcinoma [J].
Forner, Alejandro ;
Llovet, Josep M. ;
Bruix, Jordi .
LANCET, 2012, 379 (9822) :1245-1255
[7]   Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: Tips and tricks [J].
Greis, C. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2014, 58 (01) :89-95
[8]  
Ikegami Tamekazu, 1994, Japanese Journal of Gastroenterology, V91, P1290
[9]   Value of ultrasound combined with MRI in the diagnosis of primary and recurrent hepatocellular carcinoma [J].
Ji, Xiaoli ;
Zhou, Shisheng ;
Yang, Peng ;
Liu, Faqin ;
Li, Yan ;
Li, Hong .
ONCOLOGY LETTERS, 2019, 18 (06) :6180-6186
[10]   Detection of recurrent hepatocellular carcinoma on post-operative surveillance: comparison of MDCT and gadoxetic acid-enhanced MRI [J].
Kim, Kyung Ah ;
Kim, Myeong-Jin ;
Choi, Jin-Young ;
Park, Mi-Suk ;
Lim, Joon Seok ;
Chung, Yong Eun ;
Kim, Ki Whang .
ABDOMINAL IMAGING, 2014, 39 (02) :291-299