Experimental study of two phase loop thermosyphons for hybrid solar systems

被引:3
|
作者
Fuso, Luciano Serconek [1 ]
Cisterna, Luis H. R. [2 ]
Mantelli, Marcia B. H. [1 ]
机构
[1] Univ Fed Santa Catarina, Heat Pipe Lab, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Tarapaca, Dept Mech Engn, Phase Thermosyphon Lab LABTER 2, Arica, Chile
关键词
Loop two phase thermosyphon; Multiple evaporators; Hybrid solar thermal system; Solar energy applications; THERMAL PERFORMANCE; HEAT-TRANSFER; VISUALIZATION; OSCILLATION; EVAPORATOR; PARAMETERS; STARTUP; FLOW; TUBE;
D O I
10.1016/j.enconman.2023.117550
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of thermosyphon technology to improve the efficiency of solar collectors, in thermal energy applications, has received literature increasing attention. The absence or decrease of solar radiation during nights or cloudy days can be compensated by another energy source, in the so-called hybrid solar systems. In the present paper, these systems, composed by two loop two-phase thermosyphons with independent evaporators, arranged in series and in parallel, are studied and compared between themselves for the first time in the literature. In the series configuration, the backup energy source feeds the evaporator of the auxiliary loop, which condenser is thermally connect to the evaporator of the main loop, also fed by the solar energy. In the parallel arrangement, both loops deliver the heat to a common condenser. These systems are tested under steady state conditions, keeping one or both evaporators active, representing the single (solar) or hybrid operation. The thermal resistance for both configurations are compared. Results of experiments simulating the operation throughout a typical day, including solar intermittency, are shown. In the solar intermittence tests, the backup evaporator, in the parallel arrangement, is able to compensate for solar absence 47% quicker, on average, when compared to the serial configuration. For the daily operation tests, the serial configuration is able to maintain the vapor temperature levels stable, when operating under different heat input rates between evaporators, while, in the parallel arrangement, vapor temperatures and thermal resistances varied significantly along the test.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Experimental Study on Hybrid Organic Phase Change Materials Used for Solar Energy Storage
    Wang Zanshe
    Li Ran
    Hu Juntao
    Hu Xianwei
    Gu Zhaolin
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (02) : 486 - 491
  • [42] Experimental and theoretical analysis of a closed loop two-phase thermosiphon under various states for latent heat storage
    Zhang, Shuang
    Wang, Liang
    Bai, Ye
    Lin, Xipeng
    Peng, Long
    Chen, Haisheng
    ENERGY REPORTS, 2020, 6 : 1 - 7
  • [43] Experimental study of instability characteristics of a CO2 two-phase thermosyphon loop
    Fang, Chunxue
    Tong, Zhen
    Zang, Guojian
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 142
  • [44] Experimental study on the passive regulation of a CO2 two-phase thermosyphon loop
    Tong, Zhen
    Fang, Chunxue
    Zang, Guojian
    Wu, Hao
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [45] Experimental Study of a Two-Phase Thermosyphon Loop in Conditions of High Fluidic and Thermal Loads
    Adjmi, S.
    Launay, S.
    Abid, C.
    JOURNAL OF APPLIED FLUID MECHANICS, 2019, 12 : 71 - 77
  • [46] Experimental Study on CPU Cooling System of Closed-Loop Two-Phase Thermosyphon
    Gima, Satoru
    Nagata, Takashi
    Zhang, Xing
    Fujii, Motoo
    HEAT TRANSFER-ASIAN RESEARCH, 2005, 34 (03): : 147 - 159
  • [47] Experimental investigation on extraction of shallow geothermal energy by flexible two-phase closed thermosyphons: Effect of geometric parameters
    Liu, Hao
    Wang, Xiaoyuan
    Gan, Wang
    Gao, Haojie
    Yao, Huicong
    Wang, Yinfeng
    Zhu, Yuezhao
    ENERGY AND BUILDINGS, 2023, 298
  • [48] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360
  • [49] Heat transfer characteristics in two-phase closed thermosyphons with a tubular sinter
    Imura, H
    Koito, Y
    KAGAKU KOGAKU RONBUNSHU, 2003, 29 (05) : 698 - 700
  • [50] Experimental research of a two-phase nitrogen natural circulation loop
    Reisz, S.
    Bonelli, A.
    Baudouy, B.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278