Experimental study of two phase loop thermosyphons for hybrid solar systems

被引:3
|
作者
Fuso, Luciano Serconek [1 ]
Cisterna, Luis H. R. [2 ]
Mantelli, Marcia B. H. [1 ]
机构
[1] Univ Fed Santa Catarina, Heat Pipe Lab, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Tarapaca, Dept Mech Engn, Phase Thermosyphon Lab LABTER 2, Arica, Chile
关键词
Loop two phase thermosyphon; Multiple evaporators; Hybrid solar thermal system; Solar energy applications; THERMAL PERFORMANCE; HEAT-TRANSFER; VISUALIZATION; OSCILLATION; EVAPORATOR; PARAMETERS; STARTUP; FLOW; TUBE;
D O I
10.1016/j.enconman.2023.117550
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of thermosyphon technology to improve the efficiency of solar collectors, in thermal energy applications, has received literature increasing attention. The absence or decrease of solar radiation during nights or cloudy days can be compensated by another energy source, in the so-called hybrid solar systems. In the present paper, these systems, composed by two loop two-phase thermosyphons with independent evaporators, arranged in series and in parallel, are studied and compared between themselves for the first time in the literature. In the series configuration, the backup energy source feeds the evaporator of the auxiliary loop, which condenser is thermally connect to the evaporator of the main loop, also fed by the solar energy. In the parallel arrangement, both loops deliver the heat to a common condenser. These systems are tested under steady state conditions, keeping one or both evaporators active, representing the single (solar) or hybrid operation. The thermal resistance for both configurations are compared. Results of experiments simulating the operation throughout a typical day, including solar intermittency, are shown. In the solar intermittence tests, the backup evaporator, in the parallel arrangement, is able to compensate for solar absence 47% quicker, on average, when compared to the serial configuration. For the daily operation tests, the serial configuration is able to maintain the vapor temperature levels stable, when operating under different heat input rates between evaporators, while, in the parallel arrangement, vapor temperatures and thermal resistances varied significantly along the test.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Experimental study of a two-phase thermosyphon loop with a horizontal parallel tube evaporator under non-uniform heating conditions
    Yao, Mengliang
    Gan, Yunhua
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 44
  • [32] Experimental Study on the Dynamic Heat Transfer Characteristics of a Mechanically Pumped Two-phase Cooling Loop
    Li, Lei
    Tao, Jianyun
    Gao, Wei
    FRONTIERS IN ENERGY RESEARCH, 2021, 9 (09):
  • [33] Experimental study of a novel cool-storage refrigerator with controllable two-phase loop thermosyphon
    Liu, Weixin
    Chen, Chuxiong
    Cao, Jingyu
    Wu, Lijun
    Ren, Wei
    Jiao, Dongsheng
    Pei, Gang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 (129) : 32 - 42
  • [34] Experimental study on the performance characteristics of an enhanced two-phase loop thermosyphon
    Ziapour, Behrooz M.
    Baygan, Majid
    Mohammadnia, Ali
    HEAT AND MASS TRANSFER, 2015, 51 (10) : 1487 - 1492
  • [35] Operation regimes and heat transfer coefficients in sodium two-phase thermosyphons
    Cisterna, Luis H. R.
    Cardoso, Maria C. K.
    Fronza, Eduardo L.
    Milanez, Fernando H.
    Mantelli, Marcia B. H.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152 (152)
  • [36] Experimental investigation of geyser boiling in a two-phase closed loop thermosyphon with high filling ratios
    Liu, Yun
    Li, Zhigang
    Li, Yuhua
    Kim, Seolha
    Jiang, Yuyan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 857 - 869
  • [37] Heat transfer characteristics and operational visualization of two-phase loop thermosyphon
    Zhang, Tao
    Qu, Jian
    Hua, Yu
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [38] Experimental investigation of single loop thermosyphons utilized in motorized spindle shaft cooling
    Li, Fajing
    Gao, Jianmin
    Shi, Xiaojun
    Liang, Feng
    Zhu, Ke
    APPLIED THERMAL ENGINEERING, 2018, 134 : 229 - 237
  • [39] Experimental investigation of two-phase thermosyphon loop for passive containment cooling
    Yin, Xuan
    Hu, Jian
    Chi, Xiangyu
    Li, Yaru
    Nan, Zezhao
    Wang, Naihua
    APPLIED THERMAL ENGINEERING, 2021, 184
  • [40] An insert-type two-phase closed loop thermosyphon for split-type solar water heaters
    Li, Ji
    Lin, Feng
    Niu, Gengwen
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 441 - 450