Assessment of Energy Efficiency Using an Energy Monitoring System: A Case Study of a Major Energy-Consuming Enterprise in Vietnam

被引:2
|
作者
Dat, Minh Nguyen [1 ]
Trung, Kien Duong [1 ]
Minh, Phap Vu [2 ,3 ]
Van, Chau Dinh [4 ]
Tran, Quynh T. [2 ,5 ]
Ngoc, Trung Nguyen [4 ]
机构
[1] Elect Power Univ, Fac Ind & Energy Management, Minist Ind & Trade, Hanoi 100000, Vietnam
[2] Vietnam Acad Sci & Technol, Inst Energy Sci, Hanoi 100000, Vietnam
[3] Vietnam Acad Sci & Technol, Grad Univ Sci & Technol, Fac Mat & Energy Sci, Hanoi 100000, Vietnam
[4] Elect Power Univ, Minist Ind & Trade, Dept Personnel & Org, Hanoi 100000, Vietnam
[5] Univ Hawaii Manoa, Hawaii Nat Energy Inst, Honolulu, HI 96822 USA
关键词
power monitoring system; energy management; performance evaluation; industry factory; energy efficiency; energy saving; INDUSTRIAL;
D O I
10.3390/en16135214
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Vietnam's economy has been growing rapidly in the last 20 years, leading to significant increases in energy consumption as well as in carbon emissions. Most electricity is consumed by loads of industry and construction due to the country's socio-economic development strategy. An energy saving strategy cannot be achieved if the industry factories lack energy consumption data. The installation of energy monitoring systems can help to improve energy efficiency by supplying daily, monthly, and yearly energy consumption reports. Moreover, major energy-consuming enterprises in Vietnam must implement solutions for energy-efficient use as prescribed in the Law on Energy Efficient Use. Therefore, this study aimed to determine the impact of an energy monitoring system as an improvement solution for energy efficiency in a typical major energy-consuming enterprise in Vietnam. The study's results, after six months, show that the total saved electricity after installing the power monitoring system was 191,923 kWh. The company saved approximately 19.584 USD and reduced emission to the environment by 139 tons of CO2. In addition, the return on investment time of power monitoring systems is about 14 months, while the annual energy costs of the factory can be reduced by about 9.62% per year. Therefore, power monitoring systems should be promoted in factories with different scales to control energy wastage in the domestic industry field.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Environmental assessment of deep energy refurbishment for energy efficiency-case study of an office building in New Zealand
    Ghose, Agneta
    McLaren, Sarah J.
    Dowdell, David
    Phipps, Robyn
    BUILDING AND ENVIRONMENT, 2017, 117 : 274 - 287
  • [22] A Study and Assessment of the Status of Energy Efficiency and Conservation at School Buildings
    Ragab, Karim Mohamed
    Orhan, Mehmet Fatih
    Saka, Kenan
    Zurigat, Yousef
    SUSTAINABILITY, 2022, 14 (17)
  • [23] Energy efficiency labeling of buildings: An assessment of the Brazilian case
    Batista, Norma do Nascimento
    La Rovere, Emilio Lebre
    Rodrigues Aguiar, Joao Carlos
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1179 - 1188
  • [24] Energy efficiency in a supercomputing center: A case study
    Fernández González A.
    Matellán V.
    Martínez García J.M.
    Lorenzana J.
    López M.
    Renewable Energy and Power Quality Journal, 2020, 18 : 244 - 249
  • [25] Online monitoring and assessment of energy efficiency for copper smelting process
    Chen Zhuo
    Zhu Zhen-yu
    Wang Xiao-na
    Song Yan-po
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2019, 26 (08) : 2149 - 2159
  • [26] Energy efficiency of a confectionery plant - Case study
    Wojdalski, Janusz
    Grochowicz, Jozef
    Drozdz, Bogdan
    Bartoszewska, Katarzyna
    Zdanowska, Paulina
    Kupczyk, Adam
    Ekielski, Adam
    Florczak, Iwona
    Hasny, Aleksandra
    Wojcik, Grazyna
    JOURNAL OF FOOD ENGINEERING, 2015, 146 : 182 - 191
  • [27] Assessment of energy efficiency and sustainability scenarios in the transport system
    López E.
    Monzón A.
    Pfaffenbichler P.C.
    European Transport Research Review, 2012, 4 (1) : 47 - 56
  • [28] Management and Energy Efficiency Study Case Concerning CHP Implementation
    Pungaru, Liviu Eduard
    Istrate, Marcel
    Diaconu, Catalin
    2014 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE), 2014, : 1025 - 1029
  • [29] Performance Assessment System for Energy Efficiency in Wastewater Systems
    Jorge, Catarina
    Almeida, Maria do Ceu
    Covas, Didia
    WATER, 2021, 13 (13)
  • [30] The impact of auxiliary energy on the efficiency of the heating and cooling system: Monitoring of low-energy buildings
    Kalz, Doreen E.
    Herkel, Sebastian
    Wagner, Andreas
    ENERGY AND BUILDINGS, 2009, 41 (10) : 1019 - 1030