Towards point-of-care manufacturing and analysis of immediate-release 3D printed hydrocortisone tablets for the treatment of congenital adrenal hyperplasia

被引:20
|
作者
Yang, Tzuyi L. [1 ]
Stogiannari, Melpomeni [1 ]
Janeczko, Sylwia [2 ]
Khoshan, Marva [1 ]
Lin, Yueyuan [1 ]
Isreb, Abdullah [3 ]
Habashy, Rober [4 ]
Ltowicz, Joanna Giebu [2 ]
Peak, Matthew [5 ]
Alhnan, Mohamed A. [1 ]
机构
[1] Kings Coll London, Inst Pharmaceut Sci, Ctr Pharmaceut Med Res, 150 Stamford St, London SE1 9NH, England
[2] Med Univ Warsaw, Fac Pharm Lab Med Div, Warsaw, Poland
[3] Liverpool John Moores Univ, Sch Pharm & Biomol Sci, Liverpool, England
[4] SGS Quay Pharmaceut Ltd, Deeside, Wales
[5] Alder Hey Childrens NHS Fdn Trust, Paediat Med Res Unit, Liverpool L12 2AP, England
关键词
Adrenal insufficiency; Thermos; -sensitive; Hotmelt extrusion; Personalized medicine; Additive manufacturing; Real-time release; NEAR-INFRARED SPECTROSCOPY; DRUG-RELEASE; API; PAT; CHILDREN; QUALITY;
D O I
10.1016/j.ijpharm.2023.123072
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Hydrocortisone (HC) is the preferred drug in children with congenital adrenal hyperplasia due to its lower potency as well as fewer reports of side effects. Fused deposition modelling (FDM) 3D printing holds the potential to produce low-cost personalised doses for children at the point of care. However, the compatibility of the thermal process to produce immediate-release bespoke tablets for this thermally labile active is yet to be established. This work aims to develop immediate-release HC tablets using FDM 3D printing and assess drug contents as a critical quality attribute (CQA) using a compact, low-cost near-infrared (NIR) spectroscopy as a process analytical technology (PAT). The FDM 3D printing temperature (140 degrees C) and drug concentration in the filament (10%-15% w/w) were critical parameters to meet the compendial criteria for drug contents and impurities. Using a compact low-cost NIR spectral device over a wavelength of 900-1700 nm, the drug contents of 3D printed tablets were assessed. Partial least squares (PLS) regression was used to develop individual calibration models to detect HC content in 3D printed tablets of lower drug contents, small caplet design, and relatively complex formula. The models demonstrated the ability to predict HC concentrations over a wide concentration range (0-15% w/w), which was confirmed by HPLC as a reference method. Ultimately, the capability of the NIR model had preceding dose verification performance on HC tablets, with linearity (R2 = 0.981) and accuracy (RMSECV = 0.46%). In the future, the integration of 3DP technology with non-destructive PAT techniques will accelerate the adoption of ondemand, individualised dosing in a clinical setting.
引用
收藏
页数:9
相关论文
共 33 条
  • [31] A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out
    Salve, Mary
    Mandal, Aurnab
    Amreen, Khairunnisa
    Rao, B. V. V. S. N. Prabhakar
    Pattnaik, Prasant Kumar
    Goel, Sanket
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [32] Point-of-care treatment of geometrically complex midfacial critical-sized bone defects with 3D-Printed scaffolds and autologous stromal vascular fraction
    Singh, Srujan
    Nyberg, Ethan L.
    O'Sullivan, Aine N.
    Farris, Ashley
    Rindone, Alexandra N.
    Zhang, Nicholas
    Whitehead, Emma C.
    Zhou, Yuxiao
    Mihaly, Eszter
    Achebe, Chukwuebuka C.
    Zbijewski, Wojciech
    Grundy, Will
    Garlick, David
    Jackson, Nicolette D.
    Taguchi, Takashi
    Takawira, Catherine
    Lopez, Joseph
    Lopez, Mandi J.
    Grant, Michael P.
    Grayson, Warren L.
    BIOMATERIALS, 2022, 282
  • [33] A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out (vol 70, 9501710, 2021)
    Salve, Mary
    Mandal, Aurnab
    Amreen, Khairunnisa
    Rao, B. V. V. S. N. Prabhakar
    Pattnaik, Prasant Kumar
    Goel, Sanket
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71