Partial discharge detection on power equipment using a magneto-resistive sensor

被引:5
|
作者
Chen, Yun [1 ,3 ]
Heredia, Luis Carlos Castro [1 ]
Smit, Johan J. [1 ,2 ]
Niasar, Mohamad Ghaffarian [1 ]
Ross, Robert [1 ,2 ]
机构
[1] Delft Univ Technol, Fac Elect Engn Math & Comp Sci, High Voltage Technol Grp, NL-2628 CD Delft, Netherlands
[2] Inst Sci & Dev, IWO, NL-6711 GG Ede, Netherlands
[3] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
基金
欧盟地平线“2020”;
关键词
Cross-linked polyethylene (XLPE) cable; (Electro)magnetic field measurement; Giant magneto-resistive (GMR); Gas-insulated systems (GIS); High-frequency current transformers (HFCT); Partial discharges (PD); Sensors; DIAGNOSTICS; VOLTAGE; CABLE;
D O I
10.1016/j.ijepes.2023.109270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharges (PD) detection is an effective diagnostic method to assess the insulation condition of electrical power equipment in the high-voltage laboratory or field tests. This paper presents a non-contacting PD detection method for power equipment. The method is based on an extra high-sensitivity adapted giant magneto-resistive (xMR) sensor that measures the magnetic field produced by the PD currents. Firstly, this paper describes the sensor's relevant principle and signal conditioning circuit. Next, the sensor's typical performance, including the frequency response and time-domain response to calibrator PD pulses, is measured and compared with our previous work. The results indicate that the xMR system's bandwidth is improved to the MHz range. Finally, PD experiments are carried out and compared with measurements using a commercially available high-frequency current transformer (HFCT), which allows for verification of the coherence of the results concerning the PD pulses and phase-resolved PD (PRPD) patterns. The results show that PD in a cross-linked polyethylene (XLPE) cable or a gas-insulated system (GIS) with artificial discharging defects is successfully measured, demonstrating the sensitivity and performance of the xMR system for PD detection.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Giant Magneto-Resistive Effect based Sensor on Laser Direct Structured MID Substrates
    Fischer, Eike Christian
    Bengsch, Sebastian
    de Wall, Sascha
    Wurz, Marc Christopher
    2020 IEEE 70TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2020), 2020, : 439 - 444
  • [32] Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors
    Kanno, Akitake
    Nakasato, Nobukazu
    Oogane, Mikihiko
    Fujiwara, Kosuke
    Nakano, Takafumi
    Arimoto, Tadashi
    Matsuzaki, Hitoshi
    Ando, Yasuo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [33] Design of a UHF Antenna for Partial Discharge Detection of Power Equipment
    Wang, Youyuan
    Wu, Junfeng
    Chen, Weigen
    Wang, Yajun
    JOURNAL OF SENSORS, 2014, 2014
  • [34] DEVELOPMENT AND APPLICATION OF WIDE BANDWIDTH MAGNETO-RESISTIVE SENSOR BASED EDDY CURRENT PROBE
    Wincheski, Buzz
    Simpson, John
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 388 - 395
  • [35] Monitoring Method of Piston Ring Wearing Using Magneto-Resistive Sensor for Low-Speed Marine Engine
    Zhang Y.
    Yang J.
    Neiranji Xuebao/Transactions of CSICE (Chinese Society for Internal Combustion Engines), 2020, 38 (04): : 368 - 374
  • [36] Magnetic flux leakage nde using giant magneto-resistive (GMR) sensors
    Singh, W. Sharatchandra
    Rao, B. P. C.
    Nand, K. Krishna
    Thirunavukkarasu, S.
    Jayakumar, T.
    Raj, Baldev
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 27A AND 27B, 2008, 975 : 857 - +
  • [37] Using magneto-resistive sensors to monitor animal behaviour: a case study using limpets
    Wadke, P. M.
    Burrows, M. T.
    Meldrum, D.
    Davies, A. J.
    2007 OCEANS, VOLS 1-5, 2007, : 1471 - 1476
  • [38] Giant Magneto-Resistive Sensor based Magnetic Flux Leakage Technique for Inspection of Track Ropes
    Singh, W. Sharatchandra
    Rao, B. P. C.
    Mahadevan, S.
    Jayakumar, T.
    Raj, Baldev
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XIV), 2011, 35 : 256 - 263
  • [39] Magnetic recording on magneto-optical media using merge type giant magneto-resistive head
    Matsumoto, K
    Ozaki, K
    Chekanov, A
    Tagawa, I
    Shono, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2000, 39 (11B): : L1161 - L1163
  • [40] Partial discharge detection method for power equipment based on UHF method
    Liu S.
    Zhang J.
    International Journal of Energy Technology and Policy, 2024, 19 (1-2) : 120 - 134