Electrochemical study for simultaneous detection of procaine hydrochloride and its metabolite in biological samples using a nanostructured strong sensor

被引:5
作者
Haghighian, Farzaneh [1 ]
Ghoreishi, Sayed Mehdi [2 ]
Attaran, Abdolmohammad [1 ]
Kashani, Fahimeh Zeraatkar [2 ]
Khoobi, Asma [3 ]
机构
[1] Payam Noor Univ, Dept Chem, Delijan Branch, Delijan, Iran
[2] Univ Kashan, Fac Chem, Dept Analyt Chem, POB 87317-51167, Kashan, Iran
[3] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Zahedan 98135674, Iran
关键词
Procaine Hydrochloride; P-aminobenzoic Acid; Carbon Nanotubes; Nanostructured Sensor; Electrochemical Techniques; PARA-AMINOBENZOIC ACID; GRAPHENE OXIDE NANOCOMPOSITE; ALTERNATING LEAST-SQUARES; ELECTRODES; DESIGN; CARBON;
D O I
10.1007/s11814-022-1290-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Procaine belongs to a type of medicine that excessive dosage creates cardiac arrest and also several allergenic reactions. Thus, continuous monitoring of the drug and its metabolite is necessary for sustainable health management during treatment. The innovative aspect of nanostructure materials has great importance in the advancement of research on modified sensors. In the present study, the electrocatalytic performance of multi-walled carbon nanotubes modified carbon paste electrode was investigated for the simultaneous analysis of procaine hydrochloride and p-aminobenzoic acid with high accuracy and sensitivity. The nanostructured sensor is characterized by microscopic and electrochemical techniques, such as scanning electron microscopy and electrochemical impedance spectroscopy using [Fe(CN)(6)](3-/4-) as the redox probes. The modified sensor shows an improved voltammetric peak current than the unmodified carbon paste electrode. The electrochemical behavior of the modified sensor was studied by cyclic voltammetry and differential pulse voltammetry. The sensor kinetic parameters containing electron transfer rate constant (ks=0.47 s(-1)) and charge transfer coefficient (alpha=0.23) were calculated using cyclic voltammetry. The differential pulse voltammetry technique was also investigated in terms of linearity, lower limit of detection, lower limit of quantitation, accuracy and precision, which indicate acceptable results. Under optimized experimental conditions, the concentration linear range for procaine and PABA was obtained in the range of 2.4 to 100.0 mu M. The limit of detection values (S/N=3) were calculated to be 62.0 and 49.0 nM for detection of procaine and p-aminobenzoic acid, respectively. Also, the effects of interfering materials, repeatability and stability of the modified sensor were studied. Finally, the proposed sensor was applied for simultaneous and sensitive detection of p-aminobenzoic acid and procaine in real media such as plasma and pharmaceutical products with satisfactory results.
引用
收藏
页码:650 / 656
页数:7
相关论文
共 41 条
  • [31] Flexible electrochemical sensor constructed using an active copper center instead of unstable molybdenum carbide for simultaneous detection of toxic catechol and hydroquinone
    Zuo, Jiabao
    Shen, Yuliang
    Wang, Luyao
    Yang, Qi
    Cao, Zheng
    Song, Haiou
    Ye, Zhiwen
    Zhang, Shupeng
    [J]. MICROCHEMICAL JOURNAL, 2023, 187
  • [32] Sensitive electrochemical sensor using Zn doped Fe3O4 nanosheets/MWCNTs for simultaneous detection of dopamine and tramadol
    Nouraei, Rahem
    Babaei, Ali
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2025, 36 (04)
  • [33] Electrochemical dopamine sensor using a nanoporous gold microelectrode: a proof-of-concept study for the detection of dopamine release by scanning electrochemical microscopy
    Catota Saenz, Henry Steven
    Patricio Hernandez-Saravia, Lucas
    Selva, Jessica S. G.
    Sukeri, Anandhakumar
    Javier Espinoza-Montero, Patricio
    Bertotti, Mauro
    [J]. MICROCHIMICA ACTA, 2018, 185 (08)
  • [34] Determination of zearalenone and its metabolites in urine samples by liquid chromatography with electrochemical detection using a carbon nanotube-modified electrode
    de Andres, Fernando
    Zougagh, Mohammed
    Castaneda, Gregorio
    Rios, Angel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) : 54 - 60
  • [35] Electrochemical sensor for nitrite detection in water samples using flexible laser-induced graphene electrodes functionalized by CNT decorated by Au nanoparticles
    Nasraoui, Salem
    Al-Hamry, Ammar
    Teixeira, Priscila Rios
    Ameur, Sami
    Paterno, Leonardo G.
    Ben Ali, Mounir
    Kanoun, Olfa
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880 (880)
  • [36] A stable and efficient electrochemical sensor for hydroquinone and catechol detection in real-world water samples using mesoporous CaM@rGO nanocomposite
    Rajpurohit, Naresh A.
    Agrawal, Hardik
    Bhakar, Kaushalya
    Panchal, Kajal
    Kumar, Dinesh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 420
  • [37] Simultaneous detection of pesticides, carbendazim, and isoproturon using a novel nanocomposite based on graphene oxide/multi-wall carbon nanotube as an electrochemical sensor
    Chellappa, Vasanthi
    Annaraj, Jamespandi
    Sagadevan, Suresh
    [J]. DIAMOND AND RELATED MATERIALS, 2024, 147
  • [38] Simultaneous detection of 4-chlorophenol and 4-nitrophenol using a Ti3C2Tx MXene based electrochemical sensor
    Lei, Ling
    Li, Caoling
    Huang, Wensheng
    Wu, Kangbing
    [J]. ANALYST, 2021, 146 (24) : 7593 - 7600
  • [39] Simultaneous Hg 2+and Pb 2+detection in water samples using an electrochemical aptasensor with dual signal amplification by exonuclease III and metal-organic frameworks
    Liu, Hui
    Wang, Senyao
    He, Baoshan
    Xie, Lingling
    Cao, Xiaoyu
    Wei, Min
    Jin, Huali
    Ren, Wenjie
    Suo, Zhiguang
    Xu, Yiwei
    [J]. ANALYTICA CHIMICA ACTA, 2024, 1316
  • [40] Modeling of a novel SCHOTT B270 prism based SPR sensor using Ag-Si-BP/MXene structure for detection of specific biological samples
    Vasimalla, Yesudasu
    Pradhan, Himansu Shekhar
    [J]. OPTICAL AND QUANTUM ELECTRONICS, 2022, 54 (10)