Electrochemical study for simultaneous detection of procaine hydrochloride and its metabolite in biological samples using a nanostructured strong sensor

被引:5
作者
Haghighian, Farzaneh [1 ]
Ghoreishi, Sayed Mehdi [2 ]
Attaran, Abdolmohammad [1 ]
Kashani, Fahimeh Zeraatkar [2 ]
Khoobi, Asma [3 ]
机构
[1] Payam Noor Univ, Dept Chem, Delijan Branch, Delijan, Iran
[2] Univ Kashan, Fac Chem, Dept Analyt Chem, POB 87317-51167, Kashan, Iran
[3] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Zahedan 98135674, Iran
关键词
Procaine Hydrochloride; P-aminobenzoic Acid; Carbon Nanotubes; Nanostructured Sensor; Electrochemical Techniques; PARA-AMINOBENZOIC ACID; GRAPHENE OXIDE NANOCOMPOSITE; ALTERNATING LEAST-SQUARES; ELECTRODES; DESIGN; CARBON;
D O I
10.1007/s11814-022-1290-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Procaine belongs to a type of medicine that excessive dosage creates cardiac arrest and also several allergenic reactions. Thus, continuous monitoring of the drug and its metabolite is necessary for sustainable health management during treatment. The innovative aspect of nanostructure materials has great importance in the advancement of research on modified sensors. In the present study, the electrocatalytic performance of multi-walled carbon nanotubes modified carbon paste electrode was investigated for the simultaneous analysis of procaine hydrochloride and p-aminobenzoic acid with high accuracy and sensitivity. The nanostructured sensor is characterized by microscopic and electrochemical techniques, such as scanning electron microscopy and electrochemical impedance spectroscopy using [Fe(CN)(6)](3-/4-) as the redox probes. The modified sensor shows an improved voltammetric peak current than the unmodified carbon paste electrode. The electrochemical behavior of the modified sensor was studied by cyclic voltammetry and differential pulse voltammetry. The sensor kinetic parameters containing electron transfer rate constant (ks=0.47 s(-1)) and charge transfer coefficient (alpha=0.23) were calculated using cyclic voltammetry. The differential pulse voltammetry technique was also investigated in terms of linearity, lower limit of detection, lower limit of quantitation, accuracy and precision, which indicate acceptable results. Under optimized experimental conditions, the concentration linear range for procaine and PABA was obtained in the range of 2.4 to 100.0 mu M. The limit of detection values (S/N=3) were calculated to be 62.0 and 49.0 nM for detection of procaine and p-aminobenzoic acid, respectively. Also, the effects of interfering materials, repeatability and stability of the modified sensor were studied. Finally, the proposed sensor was applied for simultaneous and sensitive detection of p-aminobenzoic acid and procaine in real media such as plasma and pharmaceutical products with satisfactory results.
引用
收藏
页码:650 / 656
页数:7
相关论文
共 41 条
  • [21] A novel electrochemical ion imprinting sensor modified with carbon nanocomposites and its high selectivity for cadmium ion detection in real samples
    Zhang, Yi
    Xu, Wanzhen
    Liu, Yanmeng
    Huang, Weihong
    Yang, Wenming
    POLYMER INTERNATIONAL, 2023, 72 (12) : 1096 - 1103
  • [22] Enhanced Sensitive Electrochemical Sensor for Simultaneous Catechol and Hydroquinone Detection by Using Ultrasmall Ternary Pt-based Nanomaterial
    Arsalan, Muhammad
    Qiao, Xiujuan
    Awais, Azka
    Wang, Yahui
    Yang, Shuying
    Sheng, Qinglin
    Yue, Tianli
    ELECTROANALYSIS, 2021, 33 (06) : 1528 - 1538
  • [23] The Study of a Novel Tilt Sensor Using Magnetic Fluid and Its Detection Mechanism
    Su, Shuqiang
    Li, Decai
    Tan, Nanlin
    Li, Guozheng
    IEEE SENSORS JOURNAL, 2017, 17 (15) : 4708 - 4715
  • [24] Electrochemical quantification of 17α - Ethinylestradiol in biological samples using a Au/Fe3O4@TA/MWNT/GCE sensor
    Nodehi, Marzieh
    Baghayeri, Mehdi
    Ansari, Reza
    Veisi, Hojat
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 244 (244)
  • [25] Electrochemical sensor based on UiO-66-NH2/COCl-MWCNT/CB for simultaneous detection of dihydroxybenzene isomers in different water samples
    Zhang, Tingting
    Guo, Hao
    Yang, Meng
    Sun, Lei
    Zhang, Junye
    Wang, Mingyue
    Yang, Fan
    Wu, Ning
    Yang, Wu
    MICROCHEMICAL JOURNAL, 2022, 175
  • [26] Sensitive electrochemical sensor using a graphene-polyaniline nanocomposite for simultaneous detection of Zn(II), Cd(II), and Pb(II)
    Ruecha, Nipapan
    Rodthongkum, Nadnudda
    Cate, David M.
    Volckens, John
    Chailapakul, Orawon
    Henry, Charles S.
    ANALYTICA CHIMICA ACTA, 2015, 874 : 40 - 48
  • [27] Simultaneous Femtomolar Detection of Paracetamol, Diclofenac, and Orphenadrine Using a Carbon Nanotube/Zinc Oxide Nanoparticle-Based Electrochemical Sensor
    Kokab, Tayyaba
    Shah, Afzal
    Khan, Muhammad Abdullah
    Arshad, Muhammad
    Nisar, Jan
    Ashiq, Muhammad Naeem
    Zia, Muhammad Abid
    ACS APPLIED NANO MATERIALS, 2021, 4 (05) : 4699 - 4712
  • [28] Individual and Simultaneous Electrochemical Detection of Bisphenol A and Bisphenol S in Food Samples Using Triethylenetetramine Functionalized Multi-Walled Carbon Nanotubes
    Maşide Çakıcı
    Asiye Aslıhan Avan
    Hayati Filik
    Ece Kök Yetimoğlu
    Food Analytical Methods, 2023, 16 : 225 - 237
  • [29] Individual and Simultaneous Electrochemical Detection of Bisphenol A and Bisphenol S in Food Samples Using Triethylenetetramine Functionalized Multi-Walled Carbon Nanotubes
    Cakici, Maside
    Avan, Asiye Aslihan
    Filik, Hayati
    Yetimoglu, Ece Kok
    FOOD ANALYTICAL METHODS, 2023, 16 (01) : 225 - 237
  • [30] A reliable electrochemical sensor for determination of H2O2 in biological samples using platinum nanoparticles supported graphite/gelatin hydrogel
    Thirumalraj, Balamurugan
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Rajkumar, Chellakannu
    Yu, Lin-kuan
    Kubendhiran, Subbiramaniyan
    MICROCHEMICAL JOURNAL, 2019, 146 : 673 - 678