Electrochemical study for simultaneous detection of procaine hydrochloride and its metabolite in biological samples using a nanostructured strong sensor

被引:5
|
作者
Haghighian, Farzaneh [1 ]
Ghoreishi, Sayed Mehdi [2 ]
Attaran, Abdolmohammad [1 ]
Kashani, Fahimeh Zeraatkar [2 ]
Khoobi, Asma [3 ]
机构
[1] Payam Noor Univ, Dept Chem, Delijan Branch, Delijan, Iran
[2] Univ Kashan, Fac Chem, Dept Analyt Chem, POB 87317-51167, Kashan, Iran
[3] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Zahedan 98135674, Iran
关键词
Procaine Hydrochloride; P-aminobenzoic Acid; Carbon Nanotubes; Nanostructured Sensor; Electrochemical Techniques; PARA-AMINOBENZOIC ACID; GRAPHENE OXIDE NANOCOMPOSITE; ALTERNATING LEAST-SQUARES; ELECTRODES; DESIGN; CARBON;
D O I
10.1007/s11814-022-1290-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Procaine belongs to a type of medicine that excessive dosage creates cardiac arrest and also several allergenic reactions. Thus, continuous monitoring of the drug and its metabolite is necessary for sustainable health management during treatment. The innovative aspect of nanostructure materials has great importance in the advancement of research on modified sensors. In the present study, the electrocatalytic performance of multi-walled carbon nanotubes modified carbon paste electrode was investigated for the simultaneous analysis of procaine hydrochloride and p-aminobenzoic acid with high accuracy and sensitivity. The nanostructured sensor is characterized by microscopic and electrochemical techniques, such as scanning electron microscopy and electrochemical impedance spectroscopy using [Fe(CN)(6)](3-/4-) as the redox probes. The modified sensor shows an improved voltammetric peak current than the unmodified carbon paste electrode. The electrochemical behavior of the modified sensor was studied by cyclic voltammetry and differential pulse voltammetry. The sensor kinetic parameters containing electron transfer rate constant (ks=0.47 s(-1)) and charge transfer coefficient (alpha=0.23) were calculated using cyclic voltammetry. The differential pulse voltammetry technique was also investigated in terms of linearity, lower limit of detection, lower limit of quantitation, accuracy and precision, which indicate acceptable results. Under optimized experimental conditions, the concentration linear range for procaine and PABA was obtained in the range of 2.4 to 100.0 mu M. The limit of detection values (S/N=3) were calculated to be 62.0 and 49.0 nM for detection of procaine and p-aminobenzoic acid, respectively. Also, the effects of interfering materials, repeatability and stability of the modified sensor were studied. Finally, the proposed sensor was applied for simultaneous and sensitive detection of p-aminobenzoic acid and procaine in real media such as plasma and pharmaceutical products with satisfactory results.
引用
收藏
页码:650 / 656
页数:7
相关论文
共 41 条
  • [1] Electrochemical study for simultaneous detection of procaine hydrochloride and its metabolite in biological samples using a nanostructured strong sensor
    Farzaneh Haghighian
    Sayed Mehdi Ghoreishi
    Abdolmohammad Attaran
    Fahimeh Zeraatkar Kashani
    Asma Khoobi
    Korean Journal of Chemical Engineering, 2023, 40 : 650 - 656
  • [2] Detection of cadmium heavy metal ions using a nanostructured green sensor in food, biological and environmental samples
    Jangi, Sharifeh Hormozi
    Khoobi, Asma
    FOOD CHEMISTRY, 2024, 458
  • [4] Electrochemical detection of procaine hydrochloride anesthetic using diamond-graphene composite electrodes
    Wang, Guangke
    Leng, Guodong
    Cao, Juan
    ALEXANDRIA ENGINEERING JOURNAL, 2025, 120 : 229 - 236
  • [5] Simultaneous and sensitive determination of procaine and its metabolite for pharmaceutical quality control and pharmacokinetic research by using a graphite paste electrode
    Liu, Ai-Lin
    Wang, Jia-Dong
    Chen, Wei
    Xia, Xing-Hua
    Chen, Yuan-Zhong
    Lin, Xin-Hua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1343 - 1351
  • [6] Electrochemical sensing of mesalazine and its N-acetylated metabolite in biological samples using functionalized carbon nanotubes
    Nigovic, Biljana
    Sadikovic, Mirela
    Juric, Sandra
    TALANTA, 2016, 147 : 50 - 58
  • [7] Electrochemical sensor based on a chitosan-molybdenum vanadate nanocomposite for detection of hydroxychloroquine in biological samples
    Monsef, Rozita
    Salavati-Niasari, Masoud
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2022, 613 : 1 - 14
  • [8] First report for simultaneous determination of methyldopa and hydrochlorothiazide using a nanostructured based electrochemical sensor
    Tajik, Somayeh
    Taher, Mohammad Ali
    Beitollahi, Hadi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 704 : 137 - 144
  • [9] Preparation of graphene oxide and its application for improving the properties of an electrochemical sensor for the determination of bambuterol hydrochloride in real samples
    Zhang, Yue
    E, Yifeng
    Wang, Yi
    Li, Donghui
    Liu, Yuting
    ANALYTICAL METHODS, 2020, 12 (03) : 288 - 296
  • [10] The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples
    Qader, Bakhtiyar
    Hussain, Issam
    Baron, Mark
    Estevez-Brito, Rafael
    Cassella, John Paul
    Gonzalez-Rodriguez, Jose
    MOLECULES, 2022, 27 (06):