Arthroscopic Meniscal Healing following Medial Meniscus Posterior Root Repair: A Comparison between Two Suture Materials

被引:5
作者
Okazaki, Yuki [1 ,2 ]
Furumatsu, Takayuki [1 ,2 ]
Hiranaka, Takaaki [1 ,2 ]
Zhang, Ximing [1 ,2 ]
Kintaka, Keisuke [1 ,2 ]
Higashihara, Naohiro [1 ,2 ]
Tamura, Masanori [1 ,2 ]
Kodama, Yuya [1 ,2 ]
Kamatsuki, Yusuke [1 ,2 ]
Ozaki, Toshifumi [1 ,2 ]
机构
[1] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Orthopaed Surg, 2-5-1 Shikata Cho,Kita Ku, Okayama 7008558, Japan
[2] Tsuyama Chuo Hosp, Dept Orthopaed Surg, Okayama, Japan
关键词
clinical outcome; medial meniscus; meniscal healing; posterior root tear; suture material; TRANSTIBIAL PULLOUT REPAIR; CLINICAL-OUTCOMES; BIOMECHANICAL CONSEQUENCES; TEAR; ATTACHMENT; FIBERWIRE; STRENGTH;
D O I
10.1055/s-0042-1750047
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently, transtibial pullout repair of the medial meniscus (MM) posterior root tear (PRT) has become widely accepted and provides satisfactory clinical outcomes. Widening after cyclic loading or ultimate failure load using different suture materials and configurations has been studied. However, no study has compared the clinical outcomes using different suture materials. This study aimed to evaluate the clinical outcomes after performing MMPRT pullout repair using different suture materials. We hypothesized that better clinical outcomes would be achieved using ultra-high molecular weight polyethylene (UHMWPE) tape compared with a normal polyester suture. Thirty-seven patients who underwent MM posterior root repair between November 2019 and May 2020 were retrospectively investigated. Pullout repair was performed using a hollow no. 0 polyester suture ( n = 14) and UHMWPE tape ( n = 23). Clinical outcomes were assessed preoperatively and at 1 year postoperatively, using the Lysholm knee score, Knee Injury and Osteoarthritis Outcome Score, and visual analogue scale (VAS) pain score. The meniscal healing status was assessed using an arthroscopic scoring system (range: 0-10). All clinical scores were improved significantly in both groups. However, significantly higher meniscal healing scores and decreased VAS pain scores were observed in the UHMWPE group (7.3 +/- 0.9 and 7.7 +/- 11.3, respectively) than in the polyester group (5.6 +/- 2.1 and 18.4 +/- 18.6, respectively; p < 0.01). Suture cut-out and loss of the root continuity were observed in some cases (three cases [21.4%] in the polyester suture group and one case [4.3%] in the UHMWPE tape group). Both suture materials led to satisfactory clinical outcomes at 1 year postoperatively, whereas the UHMWPE tape was useful for obtaining good meniscal healing and decreasing the VAS pain score.
引用
收藏
页码:1200 / 1208
页数:9
相关论文
共 50 条
[1]   Biomechanical consequences of a tear of the posterior root of the medial meniscus [J].
Allaire, Robert ;
Muriuki, Muturi ;
Gilbertson, Lars ;
Harner, Christopher D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (09) :1922-1931
[2]   Role of mesenchymal stem cells in meniscal repair [J].
Angele P. ;
Kujat R. ;
Koch M. ;
Zellner J. .
Journal of Experimental Orthopaedics, 1 (1) :1-9
[3]   Biomechanical Comparison of Arthroscopic Repair Constructs for Meniscal Root Tears [J].
Anz, Adam W. ;
Branch, Eric A. ;
Saliman, Justin D. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (11) :2699-2706
[4]   Medial Meniscus Posterior Root Tear Treatment: A Matched Cohort Comparison of Nonoperative Management, Partial Meniscectomy, and Repair [J].
Bernard, Christopher D. ;
Kennedy, Nicholas I. ;
Tagliero, Adam J. ;
Camp, Christopher L. ;
Saris, Daniel B. F. ;
Levy, Bruce A. ;
Stuart, Michael J. ;
Krych, Aaron J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (01) :128-132
[5]   A Biomechanical Comparison of the Pullout Strength of No. 2 FiberWire Suture and 2-mm FiberWire Tape in Bovine Rotator Cuff Tendons [J].
Bisson, Leslie J. ;
Manohar, Leslie M. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (11) :1463-1468
[6]   In Vitro Biomechanical Evaluation and Comparison of FiberWire, FiberTape, OrthoFiber, and Nylon Leader Line for Potential Use During Extraarticular Stabilization Of Canine Cruciate Deficient Stifles [J].
Burgess, Richard ;
Elder, Steve ;
McLaughlin, Ron ;
Constable, Peter .
VETERINARY SURGERY, 2010, 39 (02) :208-215
[7]  
Cho Jin-Ho, 2014, Knee Surg Relat Res, V26, P106, DOI 10.5792/ksrr.2014.26.2.106
[8]   The MRI findings of meniscal root tear of the medial meniscus: emphasis on coronal, sagittal and axial images [J].
Choi, Sang-Hee ;
Bae, Sooho ;
Ji, Suk Kyeong ;
Chang, Moon Jong .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (10) :2094-2099
[9]  
Chung KS, 2018, ARTHROSCOPY, V34, P530, DOI [10.1016/j.arthro.2017.09.041, 10.1016/j.arthro.2017.08.266]
[10]   A meta-analysis of clinical and radiographic outcomes of posterior horn medial meniscus root repairs [J].
Chung, Kyu Sung ;
Ha, Jeong Ku ;
Ra, Ho Jong ;
Kim, Jin Goo .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (05) :1455-1468