Optic nerve sheath diameter measured by ultrasonography versus Magnetic Resonance Imaging for diagnosing increased intracranial pressure: a systematic review and meta-analysis

被引:5
作者
Xu, Nan [1 ]
Zhu, Qiang [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Ultrasonog, 1 Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
关键词
optic nerve sheath; ultrasonography; intracranial pressure; magnetic resonance imaging; meta-analysis; CEREBROSPINAL-FLUID; ULTRASOUND; ACCURACY;
D O I
10.11152/mu-4037
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To compare the accuracy of the optic nerve sheath diameter (ONSD) measured by ocular ultrasonography (US) versus magnetic resonance imaging (MRI) for the diagnosis of increased intracranial pressure (ICP). Material and methods: A systematic search of studies evaluating US ONSD or MRI ONSD for the diagnosis of increased ICP was performed. Data were extracted independently by two authors. We used the bivariate random-effects model to evaluate the diagnostic feasibility of measuring the ONSD in patients increased ICP. A summary receiver operating characteristic (SROC) graph was adopted to calculate sensitivity and specificity. Subgroup analysis was used to explore potential difference in US ONSD and MRI ONSD. Results: A total of 31 studies were included, in which there were 1783 patients diagnosed with US ONSD and 730 patients diagnosed with MRI ONSD. Twenty studies reporting US ONSD were included for quantitative synthesis. The US ONSD had a high diagnostic accuracy, involving estimated sensitivity of 0.92 (95%CI 0.87-0.95), estimated specificity of 0.85 (95%CI 0.79-0.89), positive likelihood ratio (PLR) of 6.0 (95%CI 4.3-8.4), negative likelihood ratio (NLR) of 0.10 (95%CI 0.06-0.15) and Diagnostic Odds Ratio (DOR) of 62 (95%CI 33-117). The data of 11 studies adopting MRI ONSD was pooled. The MRI ONSD demonstrated estimated sensitivity of 0.70 (95%CI 0.60-0.78), estimated specificity of 0.85 (95%CI 0.80-0.90), PLR of 4.8 (95%CI 3.4-6.7), NLR of 0.35 (95%CI 0.27-0.47) and DOR of 13 (95%CI 8-22). The subgroup analysis showed that US ONSD demonstrated a higher sensitivity (0.92 versus 0.70; p<0.01) and almost equal specificity (0.85 vs. 0.85; p=0.67) compared with MRI ONSD. Conclusion: Measurement of ONSD can be a useful tool to predict raised ICP. The US ONSD demonstrated better accuracy than MRI ONSD for the diagnosis of increased ICP.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Transvaginal ultrasound vs magnetic resonance imaging for diagnosing deep infiltrating endometriosis: systematic review and meta-analysis
    Guerriero, S.
    Saba, L.
    Pascual, M. A.
    Ajossa, S.
    Rodriguez, I.
    Mais, V.
    Alcazar, J. L.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 51 (05) : 586 - +
  • [42] Performance comparison of ultrasonography and magnetic resonance imaging in their diagnostic accuracy of placenta accreta spectrum disorders: a systematic review and meta-analysis
    Hong, Shibin
    Le, Yiping
    Lio, Ka U.
    Zhang, Ting
    Zhang, Yu
    Zhang, Ning
    [J]. INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [43] The magnetic resonance imaging assessment of optic nerve sheath diameter in pediatric acute liver failure patients
    Dogan, G. M.
    Sigirci, A.
    Okut, G.
    Cicek, E.
    Dogan, S. M.
    Yilmaz, S.
    Arslan, A. K.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (03) : 853 - 859
  • [44] Computed tomography versus magnetic resonance imaging for diagnosing cervical lymph node metastasis of head and neck cancer: a systematic review and meta-analysis
    Sun, J.
    Li, B.
    Li, C. J.
    Li, Y.
    Su, F.
    Gao, Q. H.
    Wu, F. L.
    Yu, T.
    Wu, L.
    Li, L. J.
    [J]. ONCOTARGETS AND THERAPY, 2015, 8 : 1291 - 1313
  • [45] Diagnostic performance of magnetic resonance imaging and ultrasonography on the detection of cesarean scar pregnancy A meta-analysis
    Xiao, Xiaoyi
    Ding, Rixing
    Peng, Lei
    Liu, Huaping
    Zhu, Yun
    [J]. MEDICINE, 2021, 100 (48)
  • [46] Diagnostic performance of optic nerve sheath diameter for predicting neurologic outcome in post-cardiac arrest patients: A systematic review and meta-analysis
    Lee, Sun Hwa
    Yun, Seong Jong
    [J]. RESUSCITATION, 2019, 138 : 59 - 67
  • [47] Diagnosis of placenta accreta spectrum in high-risk women using ultrasonography or magnetic resonance imaging: systematic review and meta-analysis
    De Oliveira Carniello, M.
    Oliveira Brito, L. G.
    Sarian, L. O.
    Bennini, J. R.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2022, 59 (04) : 428 - 436
  • [48] Optic nerve sheath diameter threshold by ocular ultrasonography for detection of increased intracranial pressure in Korean adult patients with brain lesions
    Lee, Si Un
    Jeon, Jin Pyeong
    Lee, Hannah
    Han, Jung Ho
    Seo, Mingu
    Byoun, Hyoung Soo
    Cho, Won-Sang
    Ryu, Ho Geol
    Kang, Hyun-Seung
    Kim, Jeong Eun
    Kim, Heung Cheol
    Jang, Kyung-Sool
    [J]. MEDICINE, 2016, 95 (41)
  • [49] Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury
    Sekhon, Mypinder S.
    Griesdale, Donald E.
    Robba, Chiara
    McGlashan, Nick
    Needham, Edward
    Walland, Katherine
    Shook, Alyssa C.
    Smielewski, Peter
    Czosnyka, Marek
    Gupta, Arun K.
    Menon, David K.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (09) : 1267 - 1274
  • [50] Radiotherapy for the treatment of optic nerve sheath meningioma: A systematic review and meta-analysis
    Melo, Lafsa Pereira de
    Viani, Gustavo Arruda
    Paula, Jayter Silva de
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 165 : 135 - 141