Optic nerve sheath diameter measured by ultrasonography versus Magnetic Resonance Imaging for diagnosing increased intracranial pressure: a systematic review and meta-analysis

被引:5
作者
Xu, Nan [1 ]
Zhu, Qiang [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Ultrasonog, 1 Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
关键词
optic nerve sheath; ultrasonography; intracranial pressure; magnetic resonance imaging; meta-analysis; CEREBROSPINAL-FLUID; ULTRASOUND; ACCURACY;
D O I
10.11152/mu-4037
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To compare the accuracy of the optic nerve sheath diameter (ONSD) measured by ocular ultrasonography (US) versus magnetic resonance imaging (MRI) for the diagnosis of increased intracranial pressure (ICP). Material and methods: A systematic search of studies evaluating US ONSD or MRI ONSD for the diagnosis of increased ICP was performed. Data were extracted independently by two authors. We used the bivariate random-effects model to evaluate the diagnostic feasibility of measuring the ONSD in patients increased ICP. A summary receiver operating characteristic (SROC) graph was adopted to calculate sensitivity and specificity. Subgroup analysis was used to explore potential difference in US ONSD and MRI ONSD. Results: A total of 31 studies were included, in which there were 1783 patients diagnosed with US ONSD and 730 patients diagnosed with MRI ONSD. Twenty studies reporting US ONSD were included for quantitative synthesis. The US ONSD had a high diagnostic accuracy, involving estimated sensitivity of 0.92 (95%CI 0.87-0.95), estimated specificity of 0.85 (95%CI 0.79-0.89), positive likelihood ratio (PLR) of 6.0 (95%CI 4.3-8.4), negative likelihood ratio (NLR) of 0.10 (95%CI 0.06-0.15) and Diagnostic Odds Ratio (DOR) of 62 (95%CI 33-117). The data of 11 studies adopting MRI ONSD was pooled. The MRI ONSD demonstrated estimated sensitivity of 0.70 (95%CI 0.60-0.78), estimated specificity of 0.85 (95%CI 0.80-0.90), PLR of 4.8 (95%CI 3.4-6.7), NLR of 0.35 (95%CI 0.27-0.47) and DOR of 13 (95%CI 8-22). The subgroup analysis showed that US ONSD demonstrated a higher sensitivity (0.92 versus 0.70; p<0.01) and almost equal specificity (0.85 vs. 0.85; p=0.67) compared with MRI ONSD. Conclusion: Measurement of ONSD can be a useful tool to predict raised ICP. The US ONSD demonstrated better accuracy than MRI ONSD for the diagnosis of increased ICP.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients
    Dikmetas, Cesareddin
    Ergin, Mehmet
    Duman, Cigdem Savas
    Gulpembe, Mustafa
    Acar, Tarik
    Yavuz, Kenan
    Cander, Basar
    Girisgin, Sadik
    Kocak, Sedat
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2020, 19 (01) : 40 - 45
  • [32] Ultrasound versus magnetic resonance imaging for Morton neuroma: systematic review and meta-analysis
    Bianca Bignotti
    Alessio Signori
    Maria Pia Sormani
    Luigi Molfetta
    Carlo Martinoli
    Alberto Tagliafico
    European Radiology, 2015, 25 : 2254 - 2262
  • [33] Optic nerve sheath diameter measurements using ultrasonography to diagnose raised intracranial pressure in preeclampsia: an observational study
    Biswas, Jhuma
    Khatun, Nasima
    Bandyopadhyay, Rakhi
    Bhattacharya, Namrata
    Maitra, Arghya
    Mukherjee, Sayan
    Mondal, Swarnakamal
    JOURNAL OF THE TURKISH-GERMAN GYNECOLOGICAL ASSOCIATION, 2023, 24 (01) : 5 - 11
  • [34] Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
    Lin, Huien
    Li, Li
    Lin, Yi
    Wang, Wenhuan
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [35] Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure
    Agrawal, Ashish
    Cheng, Roger
    Tang, Julin
    Madhok, Debbie Y.
    CRITICAL CARE MEDICINE, 2019, 47 (06) : E495 - E501
  • [36] Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure
    Maissan, Iscander M.
    Dirven, Perjan J. A. C.
    Haitsma, Iain K.
    Hoeks, Sanne E.
    Gommers, Diederik
    Stolker, Robert Jan
    JOURNAL OF NEUROSURGERY, 2015, 123 (03) : 743 - 747
  • [37] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [38] Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in Children
    Le, Audrey
    Hoehn, Mary Ellen
    Smith, Mary E.
    Spentzas, Thomas
    Schlappy, David
    Pershad, Jay
    ANNALS OF EMERGENCY MEDICINE, 2009, 53 (06) : 785 - 791
  • [39] Relationship between optic nerve sheath diameter measured by magnetic resonance imaging, intracranial pressure, and neurological outcome in cardiac arrest survivors who underwent targeted temperature management
    Kang, Changshin
    Min, Jin Hong
    Park, Jung Soo
    You, Yeonho
    Yoo, Insool
    Cho, Yong Chul
    Jeong, Wonjoon
    Ahn, Hong Joon
    Ryu, Seung
    Lee, Jinwoong
    Kim, Seung Whan
    Cho, Sung Uk
    Oh, Se Kwang
    Lee, In Ho
    Lee, Byungkook
    Lee, Donghun
    Chae, Minjung Kathy
    RESUSCITATION, 2019, 145 : 43 - 49
  • [40] Relationship between intracranial pressure as measured by an epidural intracranial pressure monitoring system and optic nerve sheath diameter in healthy dogs
    Ilie, Laura A.
    Thomovsky, Elizabeth J.
    Johnson, Paula A.
    Bentley, R. Timothy
    Heng, Hock Gan
    Lee, Hee C.
    Moore, George E.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (08) : 724 - 731