Optic nerve sheath diameter measured by ultrasonography versus Magnetic Resonance Imaging for diagnosing increased intracranial pressure: a systematic review and meta-analysis

被引:5
|
作者
Xu, Nan [1 ]
Zhu, Qiang [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Ultrasonog, 1 Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
关键词
optic nerve sheath; ultrasonography; intracranial pressure; magnetic resonance imaging; meta-analysis; CEREBROSPINAL-FLUID; ULTRASOUND; ACCURACY;
D O I
10.11152/mu-4037
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To compare the accuracy of the optic nerve sheath diameter (ONSD) measured by ocular ultrasonography (US) versus magnetic resonance imaging (MRI) for the diagnosis of increased intracranial pressure (ICP). Material and methods: A systematic search of studies evaluating US ONSD or MRI ONSD for the diagnosis of increased ICP was performed. Data were extracted independently by two authors. We used the bivariate random-effects model to evaluate the diagnostic feasibility of measuring the ONSD in patients increased ICP. A summary receiver operating characteristic (SROC) graph was adopted to calculate sensitivity and specificity. Subgroup analysis was used to explore potential difference in US ONSD and MRI ONSD. Results: A total of 31 studies were included, in which there were 1783 patients diagnosed with US ONSD and 730 patients diagnosed with MRI ONSD. Twenty studies reporting US ONSD were included for quantitative synthesis. The US ONSD had a high diagnostic accuracy, involving estimated sensitivity of 0.92 (95%CI 0.87-0.95), estimated specificity of 0.85 (95%CI 0.79-0.89), positive likelihood ratio (PLR) of 6.0 (95%CI 4.3-8.4), negative likelihood ratio (NLR) of 0.10 (95%CI 0.06-0.15) and Diagnostic Odds Ratio (DOR) of 62 (95%CI 33-117). The data of 11 studies adopting MRI ONSD was pooled. The MRI ONSD demonstrated estimated sensitivity of 0.70 (95%CI 0.60-0.78), estimated specificity of 0.85 (95%CI 0.80-0.90), PLR of 4.8 (95%CI 3.4-6.7), NLR of 0.35 (95%CI 0.27-0.47) and DOR of 13 (95%CI 8-22). The subgroup analysis showed that US ONSD demonstrated a higher sensitivity (0.92 versus 0.70; p<0.01) and almost equal specificity (0.85 vs. 0.85; p=0.67) compared with MRI ONSD. Conclusion: Measurement of ONSD can be a useful tool to predict raised ICP. The US ONSD demonstrated better accuracy than MRI ONSD for the diagnosis of increased ICP.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Optic Nerve Sheath Diameter Sonography for the Diagnosis of Increased Intracranial Pressure in Nontraumatic Neurocritically Ill Patients: a Diagnostic Accuracy Systematic Review and Meta-Analysis
    Melo, Rafael Hortencio
    Gioli-Pereira, Luciana
    Machado, Fabio Santana
    Robba, Chiara
    NEUROCRITICAL CARE, 2025,
  • [22] Ultrasonography of the Optic Nerve Sheath Diameter for Diagnosis and Monitoring of Acute Mountain Sickness: A Systematic Review
    Lochner, Piergiorgio
    Falla, Marika
    Brigo, Francesco
    Pohl, Michael
    Strapazzon, Giacomo
    HIGH ALTITUDE MEDICINE & BIOLOGY, 2015, 16 (03) : 195 - 203
  • [23] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [24] Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group.
    Dubourg J.
    Messerer M.
    Karakitsos D.
    Rajajee V.
    Antonsen E.
    Javouhey E.
    Cammarata A.
    Cotton M.
    Daniel R.T.
    Denaro C.
    Douzinas E.
    Dubost C.
    Berhouma M.
    Kassai B.
    Rabilloud M.
    Gullo A.
    Hamlat A.
    Kouraklis G.
    Mannanici G.
    Marill K.
    Merceron S.
    Poularas J.
    Ristagno G.
    Noble V.
    Shah S.
    Kimberly H.
    Cammarata G.
    Moretti R.
    Geeraerts T.
    Systematic Reviews, 2 (1) : 62
  • [25] Ultrasound versus magnetic resonance imaging for Morton neuroma: systematic review and meta-analysis
    Bignotti, Bianca
    Signori, Alessio
    Sormani, Maria Pia
    Molfetta, Luigi
    Martinoli, Carlo
    Tagliafico, Alberto
    EUROPEAN RADIOLOGY, 2015, 25 (08) : 2254 - 2262
  • [26] Correlation Between Optic Nerve Sheath Diameter and Intracranial Pressure Based on Ultrasonography
    Pan, Nifang
    Xie, Jie
    He, Jian
    Wen, Shun
    Xu, Chunyang
    Zheng, Feng
    Ye, Hongwei
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2021, 11 (01) : 241 - 246
  • [27] Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure
    Hylkema, Christopher
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2016, 28 (01) : 95 - +
  • [28] Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension
    Irazuzta, Jose E.
    Brown, Martha E.
    Akhtar, Javed
    PEDIATRIC NEUROLOGY, 2016, 54 : 35 - 38
  • [29] Transvaginal ultrasound versus magnetic resonance imaging for diagnosing adenomyosis: A systematic review and head-to-head meta-analysis
    Luis Alcazar, Juan
    Vara, Julio
    Usandizaga, Claudia
    Ajossa, Silvia
    Pascual, Maria A.
    Guerriero, Stefano
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2023, 161 (02) : 397 - 405
  • [30] Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
    Jeon, Jin Pyeong
    Lee, Si Un
    Kim, Sung-Eun
    Kang, Suk Hyung
    Yang, Jin Seo
    Choi, Hyuk Jai
    Cho, Yong Jun
    Ban, Seung Pil
    Byoun, Hyoung Soo
    Kim, Young Soo
    PLOS ONE, 2017, 12 (09):