Optic nerve sheath diameter measured by ultrasonography versus Magnetic Resonance Imaging for diagnosing increased intracranial pressure: a systematic review and meta-analysis

被引:5
|
作者
Xu, Nan [1 ]
Zhu, Qiang [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Ultrasonog, 1 Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
关键词
optic nerve sheath; ultrasonography; intracranial pressure; magnetic resonance imaging; meta-analysis; CEREBROSPINAL-FLUID; ULTRASOUND; ACCURACY;
D O I
10.11152/mu-4037
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To compare the accuracy of the optic nerve sheath diameter (ONSD) measured by ocular ultrasonography (US) versus magnetic resonance imaging (MRI) for the diagnosis of increased intracranial pressure (ICP). Material and methods: A systematic search of studies evaluating US ONSD or MRI ONSD for the diagnosis of increased ICP was performed. Data were extracted independently by two authors. We used the bivariate random-effects model to evaluate the diagnostic feasibility of measuring the ONSD in patients increased ICP. A summary receiver operating characteristic (SROC) graph was adopted to calculate sensitivity and specificity. Subgroup analysis was used to explore potential difference in US ONSD and MRI ONSD. Results: A total of 31 studies were included, in which there were 1783 patients diagnosed with US ONSD and 730 patients diagnosed with MRI ONSD. Twenty studies reporting US ONSD were included for quantitative synthesis. The US ONSD had a high diagnostic accuracy, involving estimated sensitivity of 0.92 (95%CI 0.87-0.95), estimated specificity of 0.85 (95%CI 0.79-0.89), positive likelihood ratio (PLR) of 6.0 (95%CI 4.3-8.4), negative likelihood ratio (NLR) of 0.10 (95%CI 0.06-0.15) and Diagnostic Odds Ratio (DOR) of 62 (95%CI 33-117). The data of 11 studies adopting MRI ONSD was pooled. The MRI ONSD demonstrated estimated sensitivity of 0.70 (95%CI 0.60-0.78), estimated specificity of 0.85 (95%CI 0.80-0.90), PLR of 4.8 (95%CI 3.4-6.7), NLR of 0.35 (95%CI 0.27-0.47) and DOR of 13 (95%CI 8-22). The subgroup analysis showed that US ONSD demonstrated a higher sensitivity (0.92 versus 0.70; p<0.01) and almost equal specificity (0.85 vs. 0.85; p=0.67) compared with MRI ONSD. Conclusion: Measurement of ONSD can be a useful tool to predict raised ICP. The US ONSD demonstrated better accuracy than MRI ONSD for the diagnosis of increased ICP.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Dubourg, Julie
    Javouhey, Etienne
    Geeraerts, Thomas
    Messerer, Mahmoud
    Kassai, Behrouz
    INTENSIVE CARE MEDICINE, 2011, 37 (07) : 1059 - 1068
  • [2] The role of optic nerve sheath ultrasonography in increased intracranial pressure: A systematic review and meta analysis
    Berhanu, David
    Ferreira, Joana Cardoso
    Pinto, Luis Abegao
    de Sousa, Diana Aguiar
    Neto, Lia Lucas
    Ferreira, Joana Tavares
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2023, 454
  • [3] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Julie Dubourg
    Etienne Javouhey
    Thomas Geeraerts
    Mahmoud Messerer
    Behrouz Kassai
    Intensive Care Medicine, 2011, 37 : 1059 - 1068
  • [4] Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis
    Montorfano, Lisandro
    Yu, Qian
    Bordes, Stephen J.
    Sivanushanthan, Shankarapryan
    Rosenthal, Raul J.
    Montorfano, Miguel
    ULTRASOUND JOURNAL, 2021, 13 (01)
  • [5] Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis
    Robba, Chiara
    Santori, Gregorio
    Czosnyka, Marek
    Corradi, Francesco
    Bragazzi, Nicola
    Padayachy, Llewellyn
    Taccone, Fabio Silvio
    Citerio, Giuseppe
    INTENSIVE CARE MEDICINE, 2018, 44 (08) : 1284 - 1294
  • [6] Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis
    Chiara Robba
    Gregorio Santori
    Marek Czosnyka
    Francesco Corradi
    Nicola Bragazzi
    Llewellyn Padayachy
    Fabio Silvio Taccone
    Giuseppe Citerio
    Intensive Care Medicine, 2018, 44 : 1284 - 1294
  • [7] Optic nerve sheath diameter measurement for predicting raised intracranial pressure in pediatric patients: A systematic review and meta-analysis
    Lee, Sun Hwa
    Yun, Seong Jong
    Kim, Dong Hyeon
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 177 - 186
  • [8] Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: a meta-analysis
    Kim, Sung-Eun
    Hong, Eun Pyo
    Kim, Heung Cheol
    Lee, Si Un
    Jeon, Jin Pyeong
    ACTA RADIOLOGICA, 2019, 60 (02) : 221 - 229
  • [9] Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis
    Lisandro Montorfano
    Qian Yu
    Stephen J. Bordes
    Shankarapryan Sivanushanthan
    Raul J. Rosenthal
    Miguel Montorfano
    The Ultrasound Journal, 13
  • [10] Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis
    Kim, Eun Jung
    Koo, Bon-Nyeo
    Choi, Seung Ho
    Park, Kyoungun
    Kim, Min-Soo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (01): : 175 - 182