Endoplasmic reticulum-targeted fluorescent probes for metal-free tracking of carbon monoxide in living cells

被引:6
作者
Sarkar, Arnab [1 ]
Hansda, Samaresh [1 ]
Dutta, Tiasha [2 ,3 ]
Ghoshal, Sourav [4 ]
Mukhopadhyay, Sujay [1 ]
Sarkar, Pranab [4 ]
Mandal, Sushil Kumar [2 ,3 ]
Saha, Nimai Chandra [5 ]
Chattopadhyay, Pabitra [1 ]
Dhara, Koushik [6 ]
机构
[1] Univ Burdwan, Dept Chem, Burdwan 713104, W Bengal, India
[2] Univ Kalyani, Dept Ecol Studies, Kalyani 741235, W Bengal, India
[3] Univ Kalyani, Int Ctr Ecol Engn ICEE, Kalyani 741235, W Bengal, India
[4] Visva Bharati Univ, Dept Chem, Santini Ketan 731235, W Bengal, India
[5] Univ Burdwan, Vice Chancellors Res Grp, Burdwan 713104, W Bengal, India
[6] Sambhu Nath Coll, Dept Chem, Birbhum 731303, W Bengal, India
关键词
Fluorescent probe; CO; Endoplasmic reticulum; Confocal fluorescence microscopy; HEME OXYGENASE-1/CARBON MONOXIDE; SELECTIVE DETECTION; FLUOROGENIC PROBE; PROTEIN; ALLYL; COLOCALIZATION; ISOMERIZATION; STRESS; KINASE; ETHERS;
D O I
10.1016/j.snb.2023.134150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Endoplasmic Reticulum (ER) targetable fluorescent probes, ER-NapNO2 and ER-NapAllyl, have been designed and synthesized based on 1,8-naphthalimide fluorophore, for the selective and targeted detection of carbon monoxide (CO) in aqueous buffer medium of pH 7.4 at 37 degrees C. ER-targetable moiety, methyl sulfonamide unit, was attached with the one part with the fluorophore and another part was connected with CO reactive zone i.e. 4nitrobenzyle and allyl group. Very weak fluorescence signals were observed with both the probes due to the possible PET process operating from naphthalimide moiety to electron withdrawing units i.e.-NO2 and allyl group. Interestingly, both of the probes exhibited their selective detection behavior towards CO in aqueous reaction buffer in absence of any metal ions e.g., palladium, rhodium, iron etc. The possible expulsion of highly fluorescent naphthalimide-derivative was identified from the reaction mixture during the reaction of both the probes and CO. The detection technique is found to highly selective towards CO over various reactive oxygen, nitrogen, sulfur, and other biological species with low detection limit, 0.080 & mu;M and 0.161 & mu;M of ER-NapNO2 and ER-NapAllyl respectively. Theoretical study using time dependent density functional theory (TDDFT) optimized the end-products formed after the reaction with CO and probes which excellently corroborate with the experimental observation. Also, the sensing reactions are exothermic with computed free energy changes for ERNapNO2 and ER-NapAllyl are -158.74 kcal/mol and -28.51 kcal/mol respectively. Cellular confocal fluorescence microscopic experiments showed that these probes are also efficient to detect CO in ER specific regions in living cells.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A mitochondria-targeted fluorescent probe for imaging of endogenous carbon monoxide in living cells
    Yi, Mengwen
    Zhang, Nan
    Liu, Xiangjun
    Liu, Jing
    Zhang, Xiangru
    Wei, Yongbiao
    Shangguan, Dihua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 291
  • [22] Reaction-based small-molecule fluorescent probes for endoplasmic reticulum- and mitochondria-targeted biosensing and bioimaging
    Mehmood, Abdul Hadi
    Ullah, Faiz
    Dong, Baoli
    Liu, Hong
    SCIENCE CHINA-MATERIALS, 2024, 67 (11) : 3491 - 3530
  • [23] Hydrophobic resorufamine derivatives: Potent and selective red fluorescent probes of the endoplasmic reticulum of mammalian cells
    Phaniraj, Sahishna
    Gao, Zhe
    Rane, Digamber
    Peterson, Blake R.
    DYES AND PIGMENTS, 2016, 135 : 127 - 133
  • [24] Endoplasmic Reticulum-Targeted Fluorescent Nanodot with Large Stokes Shift for Vesicular Transport Monitoring and Long-Term Bioimaging
    Shi, Leilei
    Gao, Xihui
    Yuan, Wangzhang
    Xu, Li
    Deng, Hongping
    Wu, Chenwei
    Yang, Jiapei
    Jin, Xin
    Zhang, Chuan
    Zhu, Xinyuan
    SMALL, 2018, 14 (25)
  • [25] A New Endoplasmic Reticulum (ER)-Targeting Fluorescent Probe for the Imaging of Cysteine in Living Cells
    Zhou, Lei
    Li, Yunxia
    Zhou, Aiqin
    Zhang, Guanghui
    Cheng, Zhi-Qiang
    Ge, Yong-Xi
    Liu, Shan-Kui
    Azevedo, Ricardo Bentes
    Zhang, Juan
    Jiang, Shenglin
    Jiang, Cheng-Shi
    JOURNAL OF FLUORESCENCE, 2020, 30 (06) : 1357 - 1364
  • [26] A multifunctional fluorescent probe for tracking SO 2 fluctuation between mitochondria and endoplasmic reticulum in living cells and zebrafish
    Zhang, Hui
    Li, Furao
    Li, Qiaofeng
    Liang, Chunyan
    Wei, Yongbiao
    Zhou, Chunyan
    Lai, Zefeng
    Li, Xinchun
    Yang, Fan
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 412
  • [27] Readily Available Fluorescent Probe for Carbon Monoxide Imaging in Living Cells
    Feng, Weiyong
    Liu, Dandan
    Feng, Shumin
    Feng, Guoqiang
    ANALYTICAL CHEMISTRY, 2016, 88 (21) : 10648 - 10653
  • [28] Development of an Endoplasmic Reticulum-targeting Fluorescent Probe for the Imaging of Superoxide Anion in Living Cells
    Wei, Hua
    Wang, Yan
    Chen, Qingxian
    Sun, Yaru
    Yue, Tao
    Dong, Baoli
    JOURNAL OF FLUORESCENCE, 2023, 33 (02) : 509 - 515
  • [29] An endoplasmic reticulum-targeting fluorescent probe for the imaging of hypochlorous acid in living cells and zebrafishes
    Lu, Yaru
    Dong, Baoli
    Song, Wenhui
    Kong, Xiuqi
    Mehmood, Abdul Hadi
    Lin, Weiying
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2019, 384
  • [30] Development of an Endoplasmic Reticulum-targeting Fluorescent Probe for the Imaging of Superoxide Anion in Living Cells
    Hua Wei
    Yan Wang
    Qingxian Chen
    Yaru Sun
    Tao Yue
    Baoli Dong
    Journal of Fluorescence, 2023, 33 : 509 - 515