Retrofit Analysis of City-Scale Residential Buildings in the Hot Summer and Cold Winter Climate Zone

被引:9
作者
Ji, Yanfei [1 ]
Li, Guangchen [1 ]
Su, Fanghan [1 ]
Chen, Yixing [1 ,2 ]
Zhang, Rongpeng [2 ,3 ]
Asdrubali, Francesco
Zhang, Weirong
Li, Ning
Dai, Jian
Li, Ziwei
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[3] Hunan Univ, Sch Architecture & Planning, Changsha 410082, Peoples R China
关键词
residential buildings; building simulation; energy conservation measures; city-scale modeling; retrofit analysis; ENERGY EFFICIENCY RETROFIT; RENOVATION MEASURES; COST-EFFECTIVENESS; CHINA; PERFORMANCE; OPTIMIZATION; CHALLENGES; FRAMEWORK; AREAS; VS;
D O I
10.3390/en16176152
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The rising energy consumption in residential buildings within the hot summer and cold winter (HSCW) climate zone, driven by occupants' pursuit of improved thermal comfort, necessitates effective energy conservation measures. This study established urban building energy models for 32,145 residential buildings in Changsha City, China, and conducted a comprehensive retrofit analysis of seven energy conservation measures (ECMs). Additionally, the study assessed the impact of residents' conscious energy-saving behaviors concerning air conditioner (AC) control. The research commenced by creating six baseline models representative of the diverse building stock. Identifying seven commonly used ECMs, the study examined the potential of each measure for enhancing energy efficiency. To facilitate the analysis, a dedicated toolkit, AutoBPS-Retrofit, was developed to efficiently modify the baseline model for each ECM. Furthermore, the investigation delved into the investment cost of implementing the ECMs and evaluated their simple payback year (PBP) and net present value (NPV). The results demonstrate that tailored retrofit plans are essential when addressing envelope improvements, varying according to building types and ages. Retrofits targeting lighting systems offer both promising energy savings and favorable economic viability, albeit subject to residents' preferences. Alternatively, upgrading the AC systems emerges as the most energy-efficient approach, yet the economic assessment raises concerns. The study's findings offer practical insights for governments seeking to establish effective carbon reduction goals and policies. Moreover, the research can assist energy-saving institutions, real-estate companies, and stakeholders involved in renovation projects by offering guidance in making informed decisions to enhance energy efficiency in city-scale residential buildings.
引用
收藏
页数:19
相关论文
共 50 条
[31]   Energy-efficiency strategies of residential envelope in China's Hot Summer-Cold Winter Zone based on intermittent thermal regulation behaviour [J].
Ge, Jian ;
Li, Senmiao ;
Chen, Shuqin ;
Wang, Xinzhen ;
Jiang, Ziling ;
Shen, Cheng .
JOURNAL OF BUILDING ENGINEERING, 2021, 44
[32]   Exploring the factors and motivations influencing heating behavioral patterns and future energy use intentions in the hot summer and cold winter climate zone of China [J].
Cui, Ying ;
Yan, Da ;
Chen, Chien-fei .
ENERGY AND BUILDINGS, 2017, 153 :99-110
[33]   A simulation study on the heating characteristics of residential buildings using intermittent heating in Hot-Summer/Cold-Winter areas of China [J].
Qu, Minglu ;
Sang, Xuejing ;
Yan, Xufeng ;
Huang, Ping ;
Zhang, Bin ;
Bai, Xiaoxia .
APPLIED THERMAL ENGINEERING, 2024, 241
[34]   Optimization method for prefabricated restroom envelope energy saving characteristics in hot summer and cold winter zone [J].
Zhang, Lirui ;
Zhang, Hong ;
Xu, Xu ;
Dong, Ling .
ENERGY EXPLORATION & EXPLOITATION, 2021, 39 (03) :944-961
[35]   Identifying household cooling savings potential in the hot summer and cold winter climate zone in China: A stochastic demand frontier approach [J].
Wang, Xia ;
Ding, Chao ;
Cai, Weiguang ;
Luo, Lizi ;
Chen, Mingman .
ENERGY, 2021, 237
[36]   Optimization Analysis of the Residential Window-to-Wall Ratio Based on Numerical Calculation of Energy Consumption in the Hot-Summer and Cold-Winter Zone of China [J].
Liu, Haiqiang ;
Zhang, Zhihao ;
Ma, Xidong ;
Lu, Weite ;
Li, Dongze ;
Kojima, Shoichi .
SUSTAINABILITY, 2021, 13 (11)
[37]   Annual energy performance simulation of solar chimney in a cold winter and hot summer climate [J].
Hong, Shiyi ;
He, Guoqing ;
Ge, Wenqing ;
Wu, Qian ;
Lv, Da ;
Li, Zhengguang .
BUILDING SIMULATION, 2019, 12 (05) :847-856
[38]   Simulations of the energy performance of variable refrigerant flow system in representative operation modes for residential buildings in the hot summer and cold winter region in China [J].
Zhang, Guohui ;
Li, Xianting ;
Shi, Wenxing ;
Wang, Baolong ;
Li, Ziai ;
Cao, Yang .
ENERGY AND BUILDINGS, 2018, 174 :414-427
[39]   Multiobjective optimization of daylighting, energy, and thermal performance for form variables in atrium buildings in China's hot summer and cold winter climate [J].
Xiao, Wei ;
Zhong, Wenzhou ;
Wu, Haoran ;
Zhang, Tong .
ENERGY AND BUILDINGS, 2023, 297
[40]   Energy Efficiency for Airtightness and Exterior Wall Insulation of Passive Houses in Hot Summer and Cold Winter Zone of China [J].
Fu, Xin ;
Qian, Xiaoqian ;
Wang, Lina .
SUSTAINABILITY, 2017, 9 (07)