Effect of ambient temperature and respiration rate on nasal dominance: preliminary findings from a nostril-specific wearable

被引:0
作者
Kumar, Amit [1 ]
Joshi, Deepak [2 ]
机构
[1] Indian Inst Technol, Ctr Biomed Engn, New Delhi, India
[2] All India Inst Med Sci, Dept Biomed Engn, New Delhi, India
关键词
nasal dominance index; range of temperature oscillation in nasal breathing; inspiratory temperature; expiratory temperature; inter-nostril correlation; AIR-FLOW; INSPIRATORY FLOW; HEAT-EXCHANGE; DELIVERY; CYCLE; DISEASE; WATER; PHYSIOLOGY; FLUID;
D O I
10.1088/1752-7163/acf339
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nasal dominance (ND) determination is crucial for nasal synchronized ventilator, optimum nasal drug delivery, identifying brain hemispheric dominance, nasal airway obstruction surgery, mindfulness breathing, and for possible markers of a conscious state. Given these wider applications of ND, it is interesting to understand the patterns of ND with varying temperature and respiration rates. In this paper, we propose a method which measures peak-to-peak temperature oscillations (difference between end-expiratory and end-inspiratory temperature) for the left and right nostrils during nasal breathing. These nostril-specific temperature oscillations are further used to calculate the nasal dominance index (NDI), nasal laterality ratio (NLR), inter-nostril correlation, and mean of peak-to-peak temperature oscillation for inspiratory and expiratory phase at (1) different ambient temperatures of 18 & DEG;C, 28 & DEG;C, and 38 & DEG;C and (2) at three different respiration rate of 6 bpm, 12 bpm, and 18 bpm. The peak-to-peak temperature (T pp) oscillation range (averaged across participants; n = 8) for the left and right nostril were 3.80 & PLUSMN; 0.57 & DEG;C and 2.34 & PLUSMN; 0.61 & DEG;C, 2.03 & PLUSMN; 0.20 & DEG;C and 1.40 & PLUSMN; 0.26 & DEG;C, and 0.20 & PLUSMN; 0.02 & DEG;C and 0.29 & PLUSMN; 0.03 & DEG;C at the ambient temperature of 18 & DEG;C, 28 & DEG;C, and 38 & DEG;C respectively (averaged across participants and respiration rates). The NDI and NLR averaged across participants and three different respiration rates were 35.67 & PLUSMN; 5.53 and 2.03 & PLUSMN; 1.12; 8.36 & PLUSMN; 10.61 and 2.49 & PLUSMN; 3.69; and -25.04 & PLUSMN; 14.50 and 0.82 & PLUSMN; 0.54 at the ambient temperature of 18 & DEG;C, 28 & DEG;C, and 38 & DEG;C respectively. The Shapiro-Wilk test, and non-parametric Friedman test showed a significant effect of ambient temperature conditions on both NDI and NLR. No significant effect of respiration rate condition was observed on both NDI and NLR. The findings of the proposed study indicate the importance of ambient temperature while determining ND during the diagnosis of breathing disorders such as septum deviation, nasal polyps, nosebleeds, rhinitis, and nasal fractions, and in the intensive care unit for nasal synchronized ventilator.
引用
收藏
页数:13
相关论文
共 55 条
  • [1] Atanasov A., 2018, TRAKIA J SCI, V16, P198, DOI [10.15547/tjs.2018.03.005, DOI 10.15547/tjs.2018.03.005]
  • [2] Atanasov A T., 2019, OPEN J BIOPHYS, V09, P1, DOI [10.4236/ojbiphy.2019.91001, DOI 10.4236/OJBIPHY.2019.91001]
  • [3] Neuroregulation of Human Nasal Mucosa
    Baraniuk, James N.
    Merck, Samantha J.
    [J]. INTERNATIONAL SYMPOSIUM ON OLFACTION AND TASTE, 2009, 1170 : 604 - 609
  • [4] The electrical conductivity of human cerebrospinal fluid at body temperature
    Baumann, SB
    Wozny, DR
    Kelly, SK
    Meno, FM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 220 - 223
  • [5] Diagnostic Accuracy of Peak Nasal Inspiratory Flow and Rhinomanometry in Functional Rhinosurgery
    Bermueller, Christian
    Kirsche, Hanspeter
    Rettinger, Gerhard
    Riechelmann, Herbert
    [J]. LARYNGOSCOPE, 2008, 118 (04) : 605 - 610
  • [6] New insights into the breathing physiology from transient respiratory nasal simulation
    Bradshaw, Kimberley
    Warfield-McAlpine, Patrick
    Vahaji, Sara
    Emmerling, Jake
    Salati, Hana
    Sacks, Ray
    Fletcher, David F.
    Singh, Narinder
    Inthavong, Kiao
    [J]. PHYSICS OF FLUIDS, 2022, 34 (11)
  • [7] Exhaled breath analysis in disease detection
    Chen, Ting
    Liu, Tiannan
    Li, Ting
    Zhao, Hang
    Chen, Qianming
    [J]. CLINICA CHIMICA ACTA, 2021, 515 : 61 - 72
  • [8] COLE P, 1953, J Laryngol Otol, V67, P449, DOI 10.1017/S0022215100048908
  • [9] Intranasal Insulin Therapy for Alzheimer Disease and Amnestic Mild Cognitive Impairment A Pilot Clinical Trial
    Craft, Suzanne
    Baker, Laura D.
    Montine, Thomas J.
    Minoshima, Satoshi
    Watson, G. Stennis
    Claxton, Amy
    Arbuckle, Matthew
    Callaghan, Maureen
    Tsai, Elaine
    Plymate, Stephen R.
    Green, Pattie S.
    Leverenz, James
    Cross, Donna
    Gerton, Brooke
    [J]. ARCHIVES OF NEUROLOGY, 2012, 69 (01) : 29 - 38
  • [10] MATHEMATICAL-MODELING OF HEAT AND WATER TRANSPORT IN HUMAN RESPIRATORY-TRACT
    DAVISKAS, E
    GONDA, I
    ANDERSON, SD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (01) : 362 - 372