Assessing advanced methods in XPS and HAXPES for determining the thicknesses of high-k oxide materials: From ultra-thin layers to deeply buried interfaces

被引:6
作者
Bure, T. R. [1 ]
Renault, O. [1 ]
Nolot, E. [1 ]
Lardin, T. [1 ]
Robert-Goumet, C. [2 ]
Pauly, N. [3 ]
机构
[1] Univ Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France
[2] Univ Clermont Auvergne, Inst Pascal, Clermont Auvergne INP, CNRS, F-63000 Clermont Ferrand, France
[3] Univ Libre Bruxelles, Serv Metrol Nucl, CP 165 84, 50 Av FD Roosevelt, B-1050 Brussels, Belgium
关键词
Hard X-ray photoelectron spectroscopy (HAXPES); Inelastic background analysis; Angle-resolved X-ray photoelectron spectroscopy (ARXPS); High-kmaterials; Buried layers; Atomic layer deposition (ALD); INELASTIC BACKGROUND ANALYSIS; X-RAY REFLECTOMETRY; DEPOSITION; QUANTIFICATION;
D O I
10.1016/j.apsusc.2022.155317
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We assess advanced XPS-based methods in determining depth distribution in alumina and hafnia ALD samples of increasing thicknesses and buried layer depths. First, dose quantification of Al in ultrathin alumina is achieved through non-destructive wavelength dispersive X-ray fluorescence (WDXRF), which is confirmed by comparison to destructive liquid-phase deposition inductively coupled plasma mass spectrometry (LPD-ICPMS) (uncertainty 10 %). Second, we compare WDXRF to parallel ARXPS (pARXPS) in precise dose and thickness quantification in ultrathin alumina, and present the ability of pARXPS to accurately track linear growth during the deposition. Thickness determination of an intermediate ALD stack of silicon dioxide, hafnia, and alumina layers of 1-2 nm by pARXPS is evaluated against quantitative, reference-free grazing incidence X-ray fluorescence (GIXRF) (uncertainty 8-9 %). An alternative technique employing inelastic background analysis (IBA) is introduced as a fast and accurate method and subsequently compared with pARXPS and GIXRF thickness determinations. Finally, in thicker multilayer systems, hard X-ray photoelectron spectroscopy (HAXPES) combined with IBA is proposed for an in-depth analysis for thicknesses up to 28 nm, with generated interface locations and layer thicknesses wellaligned to nominal values. This study is a novel application of lab-based Cr-K alpha HAXPES spectra for inelastic background analysis in thick metal-oxide multilayer materials.
引用
收藏
页数:11
相关论文
共 37 条
[21]  
Spencer Benjamin, 2022, Mendeley Data, V1, DOI 10.17632/BBJNGPPF6T.1
[22]   Calculation of electron inelastic mean free paths (IMFPs) VII. Reliability of the TPP-2M IMFP predictive equation [J].
Tanuma, S ;
Powell, CJ ;
Penn, DR .
SURFACE AND INTERFACE ANALYSIS, 2003, 35 (03) :268-275
[23]   APPLICATION OF ANGLE-RESOLVED XPS ALGORITHMS TO OVERLAYERS AND CONCENTRATION GRADIENTS [J].
TIELSCH, BJ ;
FULGHUM, JE .
SURFACE AND INTERFACE ANALYSIS, 1994, 21 (09) :621-630
[24]  
Tougaard S, 1998, SURF INTERFACE ANAL, V26, P249, DOI 10.1002/(SICI)1096-9918(199804)26:4<249::AID-SIA368>3.0.CO
[25]  
2-A
[26]   BACKGROUND REMOVAL IN X-RAY PHOTOELECTRON-SPECTROSCOPY - RELATIVE IMPORTANCE OF INTRINSIC AND EXTRINSIC PROCESSES [J].
TOUGAARD, S .
PHYSICAL REVIEW B, 1986, 34 (10) :6779-6783
[27]  
Tougaard S, 1997, SURF INTERFACE ANAL, V25, P137, DOI 10.1002/(SICI)1096-9918(199703)25:3<137::AID-SIA230>3.0.CO
[28]  
2-L
[29]  
Tougaard S., 2021, SOFTWARE PACKAGES CH
[30]   Practical guide to the use of backgrounds in quantitative XPS [J].
Tougaard, Sven .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2021, 39 (01)