Association of atrial fibrillation with survival in patients with low-flow low-gradient aortic stenosis with preserved ejection fraction undergoing TAVI

被引:1
作者
Nakase, Masaaki [1 ]
Tomii, Daijiro [1 ]
Heg, Dik [2 ]
Praz, Fabien [1 ]
Stortecky, Stefan [1 ]
Lanz, Jonas [1 ]
Reineke, David [3 ]
Windecker, Stephan [1 ]
Pilgrim, Thomas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
[2] Univ Bern, CTU Bern, CH-3010 Bern, Switzerland
[3] Univ Bern, Bern Univ Hosp, Dept Cardiac Surg, Inselspital, CH-3010 Bern, Switzerland
关键词
Aortic stenosis; Atrial fibrillation; Low flow; low-gradient aortic stenosis with preserved ejection fraction; Transcatheter aortic valve implantation; END-POINT DEFINITIONS; VALVE IMPLANTATION; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; CLINICAL-TRIALS; IMPACT; ECHOCARDIOGRAPHY; RECOMMENDATIONS; PREDICTORS; OUTCOMES;
D O I
10.1093/ehjqcco/qcad045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: There is limited evidence on the prognostic significance of atrial fibrillation (AF) in patients with low flow, low-gradient aortic stenosis with preserved ejection fraction (LFLG-pEF AS). We aimed to evaluate the recovery of stroke volume after transcatheter aortic valve implantation (TAVI) and clinical outcomes in patients with LFLG-pEF AS stratified by presence or absence of AF. Methods and results: In a prospective TAVI registry, patients with preserved left ventricular ejection fraction (LVEF >= 50%) were stratified according to flow-gradient status and presence of AF. Among 2259 TAVI patients with preserved LVEF between August 2007 and June 2021, 765 had high-gradient AS (HG AS) and 444 had LFLG-pEF AS. AF was observed in 199 patients with HG AS (26.0%) and 190 patients with LFLG-pEF AS (42.8%). At 1 year, stroke volume index (SVi) was significantly improved in LFLG-pEF AS patients without AF, while SVi remained low in patients with AF (from 25.9 8.5 mL/m(2) to 37.2 9.9 mL/m(2) and from 26.8 +/- 5.1 mL/m(2) to 26.1 +/- 9.1 mL/m(2), respectively). LFLG-pEF AS patients with AF had an increased risk of 1-year all-cause mortality compared with those without AF (adjusted hazard ratio (HRadjusted) 2.57; 95% confidence interval [CI] 1.44-4.59). LFLG-pEF AS patients without AF had similar mortality compared with HG AS patients without AF (HRadjusted 0.85; 95% CI 0.49-1.46). Conclusion: Patients with LFLG-pEF AS and AF experienced no relevant recovery of stroke volume after TAVI, but a more than two-fold increased risk of death compared to patients with HG AS or LFLG-pEF AS without AF. [GRAPHICS] .
引用
收藏
页码:246 / 255
页数:9
相关论文
共 50 条
  • [21] Low-flow, Low-gradient Severe Aortic Stenosis: A Review
    Sharma, Nishant
    Sachedina, Ayaaz K.
    Kumar, Sachin
    HEART INTERNATIONAL, 2023, 17 (01): : 8 - 12
  • [22] Diagnosis and management of low-flow, low-gradient aortic stenosis
    Salemi, Arash
    Hameed, Irbaz
    Khan, Faiza M.
    Gaudino, Mario
    CURRENT OPINION IN CARDIOLOGY, 2020, 35 (02) : 87 - 94
  • [23] Clinical significance of energy loss index in patients with low-gradient severe aortic stenosis and preserved ejection fraction
    Altes, Alexandre
    Ringle, Anne
    Bohbot, Yohann
    Bouchot, Oceane
    Appert, Ludovic
    Guerbaai, Raphaelle A.
    Gun, Mesut
    Ennezat, Pierre Vladimir
    Tribouilloy, Christophe
    Marechaux, Sylvestre
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (06) : 608 - 615
  • [24] Transcatheter Aortic Valve Implantation in Patients With Low-Flow, Low-Gradient Aortic Stenosis
    Lauten, Alexander
    Zahn, Ralf
    Horack, Martin
    Sievert, Horst
    Linke, Axel
    Ferrari, Markus
    Harnath, Axel
    Grube, Eberhard
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Sack, Stefan
    Senges, Jochen
    Figulla, Hans R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 552 - 559
  • [25] Preload Stress Echocardiography Predicts Outcomes in Patients With Preserved Ejection Fraction and Low-Gradient Aortic Stenosis
    Kusunose, Kenya
    Yamada, Hirotsugu
    Nishio, Susumu
    Torii, Yuta
    Hirata, Yukina
    Seno, Hiromitsu
    Saijo, Yoshihito
    Ise, Takayuki
    Yamaguchi, Koji
    Yagi, Shusuke
    Soeki, Takeshi
    Wakatsuki, Tetsuzo
    Sata, Masataka
    CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (10)
  • [26] TAVI for low-flow, low-gradient severe aortic stenosis with preserved or reduced ejection fraction: a subgroup analysis from the German Aortic Valve Registry (GARY)
    Lauten, Alexander
    Figulla, Hans R.
    Moellmann, Helge
    Holzhey, David
    Koetting, Joachim
    Beckmann, Andreas
    Veit, Christof
    Cremer, Jochen
    Kuck, Karl-Heinz
    Lange, Ruediger
    Zahn, Ralf
    Sack, Stefan
    Schuler, Gerhard
    Walther, Thomas
    Beyersdorf, Friedhelm
    Boehm, Michael
    Heusch, Gerd
    Meinertz, Thomas
    Neumann, Till
    Welz, Armin
    Mohr, Friedrich W.
    Hamm, Christian W.
    EUROINTERVENTION, 2014, 10 (07) : 850 - 859
  • [27] Right ventricular longitudinal strain for risk stratification in low-flow, low-gradient aortic stenosis with low ejection fraction
    Dahou, Abdellaziz
    Clavel, Marie-Annick
    Capoulade, Romain
    Bartko, Philipp Emanuel
    Magne, Julien
    Mundigler, Gerald
    Bergler-Klein, Jutta
    Burwash, Ian
    Mascherbauer, Julia
    Ribeiro, Henrique B.
    O'Connor, Kim
    Baumgartner, Helmut
    Senechal, Mario
    Dumesnil, Jean G.
    Rosenhek, Raphael
    Mathieu, Patrick
    Larose, Eric
    Rodes-Cabau, Josep
    Pibarot, Philippe
    HEART, 2016, 102 (07) : 548 - 554
  • [28] Low-Flow, Low-Gradient Severe Aortic Stenosis in patients with preserved or reduced ejection fraction: a systematic literature review.
    Aguilar-Molina, Oswaldo
    Barbosa-Balaguera, Stephany
    Campo-Rivera, Natalia
    Cabrales-Salcedo, Yesi
    Camacho-Garcia, Rafael
    Herrera-Escandon, Alvaro
    CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (03)
  • [29] Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival
    Hachicha, Zeineb
    Dumesnil, Jean G.
    Bogaty, Peter
    Pibarot, Philippe
    CIRCULATION, 2007, 115 (22) : 2856 - 2864
  • [30] Paradoxical low-flow, low-gradient aortic stenosis despite preserved left ventricular ejection fraction: new insights from weights of operatively excised aortic valves
    Clavel, Marie-Annick
    Cote, Nancy
    Mathieu, Patrick
    Dumesnil, Jean G.
    Audet, Audrey
    Pepin, Andree
    Couture, Christian
    Fournier, Dominique
    Trahan, Sylvain
    Page, Sylvain
    Pibarot, Philippe
    EUROPEAN HEART JOURNAL, 2014, 35 (38) : 2655 - 2662