Current prospects of building-integrated solar PV systems and the application of bifacial PVs

被引:18
作者
Abojela, Zuher R. Khalifa [1 ,2 ]
Desa, Mohd Khairunaz Mat [2 ]
Sabry, Ahmad H. [3 ]
机构
[1] Sabratha Univ, Coll Engn, Dept Elect & Elect, Sabratha, Libya
[2] USM Engn Campus, Sch Elect & Elect, Nibong Tebal, Penang, Malaysia
[3] Al Nahrain Univ, Dept Comp Engn, Baghdad, Iraq
关键词
building-integrated PVs; energy yields; energy optimization analysis; PV installation modeling; reliability; ENERGY PERFORMANCE; ARCHITECTURAL DESIGN; CURTAIN WALL; BIPV; PHOTOVOLTAICS; OPTIMIZATION; SIMULATION; EFFICIENCY; WINDOW; OFFICE;
D O I
10.3389/fenrg.2023.1164494
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building-integrated solar photovoltaic (BIPV) systems have gained attention in current years as a way to recover the building's thermal comfort and generate sustainable energy in building structures. BIPV systems can provide shade against sunshine while generating ancillary electrical power. Over the last decades, engineers have been trying to improve the efficiency of BIPV systems. BIPV systems with various installation types, including rooftop, balcony, curtain, sunshade, and wall facade types, are being constantly researched and intensively presented for improving power efficiency and reducing air-conditioning use. This work provides an overview of solar BIPV systems and focuses particularly on existing applications of the bifacial type of BIPV systems. The motivation and an overview of BIPV systems are first introduced, followed by the study methodology considered and the contributions. This work discusses PV technologies of bifacial PVs (monocrystalline and polycrystalline bifacial modules), BIPV installation [curtains, rooftop, flat rooftop, transparent faced, balcony windows (transparent), wall opaque facade, flat roof-faced, and skylight sunshade types], simulation and optimization software (simulation software and future trends), zero-energy BIPV technology, and optimization techniques of BIPV systems. Last, suggestion amendments to the current BIPV design that possibly contribute to growing the system's effectiveness, reliability, and cost as future design theories for the whole system are presented.
引用
收藏
页数:23
相关论文
共 153 条
[51]  
Huang M. J., Renewable Energy and Sustainable Buildings
[52]   Thermal regulation of building-integrated photovoltaics using phase change materials [J].
Huang, MJ ;
Eames, PC ;
Norton, B .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (12-13) :2715-2733
[53]   Optimization of the building integrated photovoltaic system in office buildings-Focus on the orientation, inclined angle and installed area [J].
Hwang, Taeyon ;
Kang, Seokyoun ;
Kim, Jeong Tai .
ENERGY AND BUILDINGS, 2012, 46 :92-104
[54]   Temperature Analysis of the Stand-Alone and Building Integrated Photovoltaic Systems Based on Simulation and Measurement Data [J].
Idzkowski, Adam ;
Karasowska, Karolina ;
Walendziuk, Wojciech .
ENERGIES, 2020, 13 (16)
[55]   Study of thermoelectric and photovoltaic facade system for energy efficient building development: A review [J].
Irshad, Kashif ;
Habib, Khairul ;
Saidur, R. ;
Kareem, M. W. ;
Saha, Bidyut Baran .
JOURNAL OF CLEANER PRODUCTION, 2019, 209 :1376-1395
[56]   Silicon nitride passivated bifacial Cz-silicon solar cells [J].
Janssen, L. ;
Windgassen, H. ;
Baetzner, D. L. ;
Bitnar, B. ;
Neuhaus, H. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2009, 93 (08) :1435-1439
[57]  
Jayathissa P., 2016, SOL ENERG MAT SOL C, DOI [10.1016/j.solmat.2016.04.017, DOI 10.1016/J.SOLMAT.2016.04.017]
[58]   An Improved Grid Current and DC Capacitor Voltage Balancing Method for Three-Terminal Hybrid AC/DC Microgrid [J].
Jia, Hongjie ;
Xiao, Qian ;
He, Jinwei .
IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (06) :5876-5888
[59]  
Joge T., 2003, P 3 WORLD C PHOT EN
[60]   Evaluation of Building Energy Performance with Optimal Control of Movable Shading Device Integrated with PV System [J].
Jung, Dong Eun ;
Lee, Chanuk ;
Lee, Kwang Ho ;
Shin, Minjae ;
Do, Sung Lok .
ENERGIES, 2021, 14 (07)