Ex vivo assessment of the buccal and oral bone by CBCT

被引:0
|
作者
Ruetters, M. [1 ]
Kim, T-S [1 ]
Hagenfeld, D. [5 ]
Kronsteiner, D. [4 ]
Gehrig, H. [2 ]
Lux, C-J [3 ]
Sen, S. [3 ]
机构
[1] Univ Hosp Heidelberg, Dept Operat Dent, Sect Periodontol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Heidelberg, Dept Operat Dent, Sect Endodontol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[3] Univ Hosp Heidelberg, Dept Orthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[4] Univ Hosp Heidelberg, Inst Med Biometry & Informat, Neuenheimer Feld 130-3, D-69120 Heidelberg, Germany
[5] Univ Hosp Munster, Dept Periodontol & Restorat Dent, Waldeyer Str 30, D-48149 Munster, Germany
关键词
Cone beam computed tomography; Computed radiography; Periodontitis; Periodontal bone defects; Orthodontics; BEAM COMPUTED-TOMOGRAPHY; ACCURACY;
D O I
10.1007/s00056-021-00335-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Identifying buccal and oral bone as an important supporting periodontal structure for teeth provides important information for treatment planning in periodontics and orthodontics. This study aims to add evidence to the knowledge of preciseness of cone beam computed tomography (CBCT) measurements of the vertical dimension of buccal and oral bone. The hypothesis is that CBCT is an accurate and reliable method to measure vertical vestibular and oral bone loss. Methods The amount of vertical buccal and oral bone loss (bl) of 260 sites of 10 human cadavers was investigated clinically and radiographically by CBCT. Radiographic measurements were rated by two blinded raters. Measurements and the corresponding differences between clinical and radiological findings are described by medians and quartiles (Q1-Q3). For statistical analysis, Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were calculated. Results The CCC between the raters was 0.994 (95% confidence interval 0.992-0.995). The median bone loss (bl) distance from the cementoenamel junction (CEJ) to the bony defect (BD) was 3.5 mm (range 3-5 mm). The median bl measured in the CBCT was 3.8 mm (range 3.1-4.8 mm). The median difference of the 2 measurements for all sites included in the study (N = 260) was -0.2 mm (-0.7 to 0.3 mm). Conclusions CBCT seems to be an accurate and highly reliable method to detect and describe vertical buccal and oral bone loss. It could improve planning and prediction for successful combined periodontal and orthodontic therapies.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [11] Assessment of Binary Agarose-Carbopol Buccal Gels for Mucoadhesive Drug Delivery: Ex Vivo and In Vivo Characterization
    Syed, Muhammad Ali
    Hanif, Sana
    ul Ain, Noor
    Syed, Haroon Khalid
    Zahoor, Ameer Fawad
    Khan, Ikram Ullah
    Abualsunun, Walaa A.
    Jali, Abdulmajeed M.
    Qahl, Safa H.
    Sultan, Muhammad H.
    Madkhali, Osama A.
    Ahmed, Rayan A.
    Abbas, Nasir
    Hussain, Amjad
    Qayyum, Muhammad Abdul
    Irfan, Muhammad
    MOLECULES, 2022, 27 (20):
  • [12] Thermal Assessment of Ex Vivo Laser Ablation of Cortical Bone
    Pantawane, Mangesh, V
    Ho, Yee-Hsien
    Robertson, William B.
    Khan, Riaz J. K.
    Fick, Daniel P.
    Dahotre, Narendra B.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (04) : 2415 - 2426
  • [13] Buccal Bone Thickness in the Esthetic Zone of Postmenopausal Women: A CBCT Analysis
    Zhang, Christine You
    DeBaz, Christine
    Bhandal, Gazabpreet
    Alli, Foluke
    Francisco, Maria Clarinda Buencamino
    Thacker, Holly L.
    Palomo, Juan Martin
    Palomo, Leena
    IMPLANT DENTISTRY, 2016, 25 (04) : 478 - 484
  • [14] Ex Vivo Bone Model
    不详
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2013, 41 (02): : 148 - 148
  • [15] Ex vivo evaluation of bioadhesive films for buccal delivery of fentanyl
    del Consuelo, Isabel Diaz
    Falson, Francoise
    Guy, Richard H.
    Jacques, Yves
    JOURNAL OF CONTROLLED RELEASE, 2007, 122 (02) : 135 - 140
  • [16] Micellar buccal film for safe and effective control of seizures: Preparation, in vitro characterization, ex vivo permeation studies and in vivo assessment
    Salama, Alaa H.
    Basha, Mona
    Salama, Abeer A. A.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 166
  • [17] Temperature assessment in the drilling of ex vivo bovine and porcine cortical bone tissue
    Fernandes, M. G.
    Natal, R. J.
    Fonseca, E. M. M.
    Dias, M., I
    BIOMEDWOMEN, 2016, : 159 - 163
  • [18] Use of Permeapad® for prediction of buccal absorption: A comparison to in vitro, ex vivo and in vivo method
    Bibi, Hanady Ajine
    Holm, Rene
    Bauer-Brandl, Annette
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 93 : 399 - 404
  • [19] Formulation of unidirectional buccal tablet of Mirtazapine: An in vitro and ex vivo evaluation
    Koradia, Hiral
    Chaudhari, Khushbu
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2018, 43 : 233 - 242
  • [20] Optical coherence tomography in the assessment of suspicious oral lesions: An immediate ex vivo study
    Hamdoon, Zaid
    Jerjes, Waseem
    Upile, Tahwinder
    McKenzie, Gordon
    Jay, Amrita
    Hopper, Cohn
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2013, 10 (01) : 17 - 27