Ex vivo assessment of the buccal and oral bone by CBCT

被引:0
|
作者
Ruetters, M. [1 ]
Kim, T-S [1 ]
Hagenfeld, D. [5 ]
Kronsteiner, D. [4 ]
Gehrig, H. [2 ]
Lux, C-J [3 ]
Sen, S. [3 ]
机构
[1] Univ Hosp Heidelberg, Dept Operat Dent, Sect Periodontol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Heidelberg, Dept Operat Dent, Sect Endodontol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[3] Univ Hosp Heidelberg, Dept Orthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[4] Univ Hosp Heidelberg, Inst Med Biometry & Informat, Neuenheimer Feld 130-3, D-69120 Heidelberg, Germany
[5] Univ Hosp Munster, Dept Periodontol & Restorat Dent, Waldeyer Str 30, D-48149 Munster, Germany
关键词
Cone beam computed tomography; Computed radiography; Periodontitis; Periodontal bone defects; Orthodontics; BEAM COMPUTED-TOMOGRAPHY; ACCURACY;
D O I
10.1007/s00056-021-00335-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Identifying buccal and oral bone as an important supporting periodontal structure for teeth provides important information for treatment planning in periodontics and orthodontics. This study aims to add evidence to the knowledge of preciseness of cone beam computed tomography (CBCT) measurements of the vertical dimension of buccal and oral bone. The hypothesis is that CBCT is an accurate and reliable method to measure vertical vestibular and oral bone loss. Methods The amount of vertical buccal and oral bone loss (bl) of 260 sites of 10 human cadavers was investigated clinically and radiographically by CBCT. Radiographic measurements were rated by two blinded raters. Measurements and the corresponding differences between clinical and radiological findings are described by medians and quartiles (Q1-Q3). For statistical analysis, Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were calculated. Results The CCC between the raters was 0.994 (95% confidence interval 0.992-0.995). The median bone loss (bl) distance from the cementoenamel junction (CEJ) to the bony defect (BD) was 3.5 mm (range 3-5 mm). The median bl measured in the CBCT was 3.8 mm (range 3.1-4.8 mm). The median difference of the 2 measurements for all sites included in the study (N = 260) was -0.2 mm (-0.7 to 0.3 mm). Conclusions CBCT seems to be an accurate and highly reliable method to detect and describe vertical buccal and oral bone loss. It could improve planning and prediction for successful combined periodontal and orthodontic therapies.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [1] Ex vivo assessment of the buccal and oral bone by CBCT; [Ex-vivo-Beurteilung von bukkalem und oralem Knochen mittels DVT]
    Ruetters M.
    Kim T.-S.
    Hagenfeld D.
    Kronsteiner D.
    Gehrig H.
    Lux C.-J.
    Sen S.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2023, 84 (1): : 41 - 48
  • [2] Ex- vivo imaging of buccal and oral periodontal bone with low- dose CBCT in porcine jaws
    Ruetters, Maurice
    Gehrig, Holger
    Kronsteiner, Dorohtea
    Weyer, Vanessa
    Kim, Ti-Sun
    Lux, Christopher J.
    Sen, Sinan
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (01)
  • [3] CBCT assessment of alveolar buccal bone level after RME
    Pangrazio-Kulbersh, Valmy
    Jezdimir, Brynn
    Haughey, Mariana de Deus
    Kulbersh, Richard
    Wine, Paul
    Kaczynski, Richard
    ANGLE ORTHODONTIST, 2013, 83 (01) : 110 - 116
  • [4] In vivo, ex vivo and in vitro assessment of buccal permeation of drugs from delivery systems
    Pinto, Soraia
    Pintado, Manuela E.
    Sarmento, Bruno
    EXPERT OPINION ON DRUG DELIVERY, 2020, 17 (01) : 33 - 48
  • [5] Ex vivo comparison of CBCT and digital periapical radiographs for the quantitative assessment of periodontal defects
    Ruetters, Maurice
    Hagenfeld, D.
    ElSayed, N.
    Zimmermann, N.
    Gehrig, H.
    Kim, T-S
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (01) : 377 - 384
  • [6] Ex vivo comparison of CBCT and digital periapical radiographs for the quantitative assessment of periodontal defects
    Maurice Ruetters
    D. Hagenfeld
    N. ElSayed
    N. Zimmermann
    H. Gehrig
    T-S. Kim
    Clinical Oral Investigations, 2020, 24 : 377 - 384
  • [7] Formulation Development and In vitro-Ex vivo Assessment of Simvastatin Niosomal Buccal Films
    Beeravelli, Sudhakar
    Akondi, Vyasamurthy
    Nimmathota, Madhavi
    RECENT PATENTS ON NANOTECHNOLOGY, 2022, 16 (03) : 235 - 249
  • [8] Development, Characterization, and Ex Vivo Assessment of Elastic Liposomes for Enhancing the Buccal Delivery of Insulin
    Bashyal, Santosh
    Seo, Jo-Eun
    Keum, Taekwang
    Noh, Gyubin
    Lamichhane, Shrawani
    Lee, Sangkil
    PHARMACEUTICS, 2021, 13 (04)
  • [9] Design of advanced buccal films with kiwiberry extract to prevent oral mucositis: From in vitro buccal models to ex vivo studies
    Teixeira, Filipa
    Silva, Ana Margarida
    Macedo, Catarina
    Estevinho, Berta
    Sut, Stefania
    Dall'Acqua, Stefano
    Delerue-Matos, Cristina
    Costa, Paulo C.
    Rodrigues, Francisca
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 96
  • [10] A CBCT atlas of buccal cortical bone thickness in interradicular spaces
    Holmes, Patrick B.
    Wolf, Bethany J.
    Zhou, Jing
    ANGLE ORTHODONTIST, 2015, 85 (06) : 911 - 919