Parametric study for optimizing fiber-reinforced concrete properties

被引:7
作者
Khalel, Hamad Hasan Zedan [1 ]
Khan, Muhammad [1 ]
Starr, Andrew [1 ]
Sadawi, Noureddin [2 ]
Mohamed, Omar Ahmed [3 ]
Khalil, Ashraf [4 ]
Esaker, Mohamed [5 ]
机构
[1] Cranfield Univ, Cranfield, England
[2] Univ London, London, England
[3] Amhimmid Higher Inst Engn Technol, Bani Waleed, Libya
[4] Tech Univ Denmark, DTU Engn Technol, Ballerup, Denmark
[5] Univ Nottingham, Fac Engn, Univ Pk, Nottingham, England
关键词
fiber; mechanical properties; optimizing; reinforced concrete; MULTIOBJECTIVE OPTIMIZATION METHODS; COMPACTING LIGHTWEIGHT CONCRETE; MECHANICAL-PROPERTIES; STEEL FIBER; POLYMER CONCRETE; PERFORMANCE; BEHAVIOR; WASTE; IMPROVEMENT; MODEL;
D O I
10.1002/suco.202300509
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete with fiber reinforcement is stronger and more ductile than concrete without reinforcement. Significant efforts have been made to demonstrate the properties and enhancements of concrete after reinforcement with various types and shapes of fibers. However, the issue of optimization in the reinforcement process is still unanswered. There is no academic study in the literature now available that can pinpoint the ideal fiber type, quantity, and shape and, more crucially, the overall technical viability of the reinforcement. The parametric analysis in this study determines the ideal shape, size, and proportion of fibers. The input and output parameters were separated from the optimization design variables. Input parameters included assessment of samples of fresh and mechanical concrete properties and the influence of type, length, and percentage of fiber on concrete performance. The aim was to establish the most efficient relationship between fiber dose and dimension to optimize the combined responses of workability and splitting tensile, flexural, and compressive strength. The mechanical and fresh properties of concrete reinforced with four different fibers, PFRC-1, PFRC-2, SFRC-1, and SFRC-2, were tested. The analysis showed that SFRC-2-20 mm-1%, with compressive, split tensile, flexural, and workability values of 44.7 MPa, 3.64 MPa, 5.3 MPa, and 6.5 cm respectively, was the most effective combination among the materials investigated. The optimization technique employed in this study offers new, important insights into how input and output parameters relate to one another.
引用
收藏
页码:88 / 110
页数:23
相关论文
共 76 条
[1]   The possibility of enhancing some properties of self-compacting concrete by adding waste plastic fibers [J].
Al-Hadithi, Abdulkader Ismail ;
Hilal, Nahla Naji .
JOURNAL OF BUILDING ENGINEERING, 2016, 8 :20-28
[2]   Evaluation of ultra-high-performance-fiber reinforced concrete binder content using the response surface method [J].
Aldahdooh, M. A. A. ;
Bunnori, N. Muhamad ;
Johari, M. A. Megat .
MATERIALS & DESIGN, 2013, 52 :957-965
[3]   Steel fibre-reinforced high-strength concrete incorporating copper slag: Mechanical, gamma-ray shielding, impact resistance, and microstructural characteristics [J].
Ameri, Farshad ;
de Brito, Jorge ;
Madhkhan, Morteza ;
Taheri, Ramezan Ali .
JOURNAL OF BUILDING ENGINEERING, 2020, 29
[4]  
[Anonymous], 2009, BS 12390 3 2009 TEST
[5]   Experimental analysis of fiber-reinforced recycled aggregate self-compacting concrete using waste recycled concrete aggregates, polypropylene, and steel fibers [J].
Aslani, Farhad ;
Hou, Lijun ;
Nejadi, Shami ;
Sun, Junbo ;
Abbasi, Samer .
STRUCTURAL CONCRETE, 2019, 20 (05) :1670-1683
[6]   Improvement of the mechanical properties of glass fibre reinforced plastic waste powder filled concrete [J].
Asokan, P. ;
Osmani, Mohamed ;
Price, A. D. F. .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (04) :448-460
[7]   Application of response surface methodology: Predicting and optimizing the properties of concrete containing steel fibre extracted from waste tires with limestone powder as filler [J].
Awolusi, T. F. ;
Oke, O. L. ;
Akinkurolere, O. O. ;
Sojobi, A. O. .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2019, 10
[8]  
B.S.E.N. 12350-2, 2009, TESTING FRESH CONCRE
[9]  
B.S. EN 12350-2, 2009, BS 2009
[10]  
B.S.I. (British S. Institution), 2000, BS 12390 4 2000 TEST