Treatment Optimization in Linac-Based SBRT for Localized Prostate Cancer: A Single-Arc versus Dual-Arc Plan Comparison

被引:2
作者
Panizza, Denis [1 ,2 ]
Faccenda, Valeria [1 ]
Arcangeli, Stefano [2 ,3 ]
De Ponti, Elena [1 ,2 ]
机构
[1] Fdn IRCCS San Gerardo Tintori, Med Phys Dept, I-20900 Monza, Italy
[2] Univ Milano Bicocca, Sch Med & Surg, I-20126 Milan, Italy
[3] Fdn IRCCS San Gerardo dei Tintori, Radiat Oncol Dept, I-20900 Monza, Italy
关键词
prostate cancer; stereotactic body radiation therapy; extreme hypofractionation; linac; volumetric arc therapy; INTENSITY-MODULATED RADIOTHERAPY; STEREOTACTIC BODY RADIOTHERAPY; INTRA-FRACTION MOTION; INTRAFRACTION MOTION; RADIATION-THERAPY; DOSIMETRIC IMPACT; STRATEGIES; OUTCOMES; QUALITY;
D O I
10.3390/cancers16010013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Stereotactic body radiation therapy (SBRT) can be safely delivered for the treatment of localized prostate cancer. High-dose-per-fraction treatments require precise and rapid delivery of the radiation dose to the tumor, and any potential margin expansion must be balanced against the risk of increased toxicity. Since significant intrafraction prostate displacement can have a relevant impact on an extreme-hypofractionated regimen, real-time monitoring has emerged as a strategy to avoid the excessive exposure of healthy tissue or insufficient target coverage, but it requires continuous investment of resources and time. In real-world clinical practice, the utilization of organ motion management devices is not always feasible for all patients. Thus, our strategy has often been to mitigate the impact of intrafraction motion by shortening the delivery time without compromising the quality of the treatment. This was achieved through optimal patient preparation, flattening filter-free (FFF) beams, adequate margins, and a reduction in the number of arcs in the VMAT technique.Abstract This study aimed to comprehensively present data on treatment optimization in linac-based SBRT for localized prostate cancer at a single institution. Moreover, the dosimetric quality and treatment efficiency of single-arc (SA) versus dual-arc (DA) VMAT planning and delivery approaches were compared. Re-optimization was performed on twenty low-to-intermediate-risk- (36.25 Gy in 5 fractions) and twenty high-risk (42.7 Gy in 7 fractions) prostate plans initially administered with the DA FFF-VMAT technique in 2021. An SA approach was adopted, incorporating new optimization parameters based on increased planning and clinical experience. Analysis included target coverage, organ-at-risk (OAR) sparing, treatment delivery time, and the pre-treatment verification's gamma analysis-passing ratio. The SA optimization technique has consistently produced superior plans. Rectum and bladder mean doses were significantly reduced, and comparable target coverage and homogeneity were achieved in order to maintain a urethra protection strategy. The mean SA treatment delivery time was reduced by 22%; the mean monitor units increased due to higher plan complexity; and dose measurements demonstrated optimal agreement with calculations. The substantial reduction in treatment delivery time decreased the probability of prostate motion beyond the applied margins, suggesting potential decrease in treatment-related toxicity and improved target coverage in prostate SBRT. Further investigations are warranted to assess the long-term clinical outcomes.
引用
收藏
页数:11
相关论文
共 42 条
  • [1] DOSIMETRIC EFFECT OF INTRAFRACTION MOTION AND RESIDUAL SETUP ERROR FOR HYPOFRACTIONATED PROSTATE INTENSITY-MODULATED RADIOTHERAPY WITH ONLINE CONE BEAM COMPUTED TOMOGRAPHY IMAGE GUIDANCE
    Adamson, Justus
    Wu, Qiuwen
    Yan, Di
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 453 - 461
  • [2] Dose escalation for prostate stereotactic ablative radiotherapy (SABR): Late outcomes from two prospective clinical trials
    Alayed, Yasir
    Cheung, Patrick
    Pang, Geordi
    Mamedov, Alexandre
    D'Alimonte, Laura
    Deabreu, Andrea
    Commisso, Kristina
    Commisso, Angela
    Zhang, Liang
    Quon, Harvey C.
    Musunuru, Hima Bindu
    Helou, Joelle
    Loblaw, D. Andrew
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 (02) : 213 - 218
  • [3] Will SBRT replace conventional radiotherapy in patients with low-intermediate risk prostate cancer? A review
    Arcangeli, Stefano
    Scorsetti, Marta
    Alongi, Filippo
    [J]. CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2012, 84 (01) : 101 - 108
  • [4] Intra-fraction motion of the prostate is a random walk
    Ballhausen, H.
    Li, M.
    Hegemann, N-S
    Ganswindt, U.
    Belka, C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) : 549 - 563
  • [5] The effect of prostate motion during hypofractionated radiotherapy can be reduced by using flattening filter free beams
    Benedek, Hunor
    Lerner, Minna
    Nilsson, Per
    Knoos, Tommy
    Gunnlaugsson, Adalsteinn
    Ceberg, Crister
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 66 - 70
  • [6] Intensity-modulated fractionated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-B): acute toxicity findings from an international, randomised, open-label, phase 3, non-inferiority trial
    Brand, Douglas H.
    Tree, Alison C.
    Ostler, Peter
    van der Voet, Hans
    Loblaw, Andrew
    Chu, William
    Ford, Daniel
    Tolan, Shaun
    Jain, Suneil
    Martin, Alexander
    Staffurth, John
    Camilleri, Philip
    Kancherla, Kiran
    Frew, John
    Chan, Andrew
    Dayes, Ian S.
    Henderson, Daniel
    Brown, Stephanie
    Cruickshank, Clare
    Burnett, Stephanie
    Duffton, Aileen
    Griffin, Clare
    Hinder, Victoria
    Morrison, Kirsty
    Naismith, Olivia
    Hall, Emma
    van As, Nicholas
    [J]. LANCET ONCOLOGY, 2019, 20 (11) : 1531 - 1543
  • [7] Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy
    Diego Azcona, Juan
    Xing, Lei
    Chen, Xin
    Bush, Karl
    Li, Ruijiang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (05): : 1167 - 1174
  • [8] Dosimetric Impact of Intrafraction Prostate Motion and Interfraction Anatomical Changes in Dose-Escalated Linac-Based SBRT
    Faccenda, Valeria
    Panizza, Denis
    Daniotti, Martina Camilla
    Pellegrini, Roberto
    Trivellato, Sara
    Caricato, Paolo
    Lucchini, Raffaella
    De Ponti, Elena
    Arcangeli, Stefano
    [J]. CANCERS, 2023, 15 (04)
  • [9] Ultra-hypofractionated versus conventionally fractionated radiotherapy for prostate cancer (HYPO-RT-PC) : patient-reported quality-of-life outcomes of a randomised, controlled, 3 trial
    Fransson, Per
    Nilsson, Per
    Gunnlaugsson, Adalsteinn
    Beckman, Lars
    Tavelin, Bjorn
    Norman, David
    Thellenberg-Karlsson, Camilla
    Hoyer, Morten
    Lagerlund, Magnus
    Kindblom, Jon
    Ginman, Claes
    Johansson, Bengt
    Bjornlinger, Kirsten
    Seke, Mihajl
    Agrup, Mans
    Zackrisson, Bjorn
    Kjellen, Elisabeth
    Franzen, Lars
    Widmark, Anders
    [J]. LANCET ONCOLOGY, 2021, 22 (02) : 235 - 245
  • [10] Impact of Dose to the Bladder Trigone on Long-Term Urinary Function After High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer
    Ghadjar, Pirus
    Zelefsky, Michael J.
    Spratt, Daniel E.
    af Rosenschoeld, Per Munck
    Oh, Jung Hun
    Hunt, Margie
    Kollmeier, Marisa
    Happersett, Laura
    Yorke, Ellen
    Deasy, Joseph O.
    Jackson, Andrew
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (02): : 339 - 344