A new type of velocity averaging tube vortex flow sensor and measurement model of mass flow rate

被引:3
|
作者
Fang, Lide [1 ,2 ,3 ]
Liu, Yueyuan [1 ,2 ,3 ]
Zheng, Meng [1 ,2 ,3 ]
Liu, Xu [1 ,2 ,3 ]
Lan, Kang [1 ,2 ,3 ]
Wang, Fan [1 ,2 ,3 ]
Yan, Xiaoli [1 ,2 ,3 ]
机构
[1] Hebei Univ, Coll Qual & Tech Supervis, Baoding 071002, Peoples R China
[2] Hebei Univ, Natl & Local Joint Engn Res Ctr Metrol Instrument, Baoding 071002, Hebei, Peoples R China
[3] Hebei Key Lab Energy Metering & Safety Testing Tec, Baoding 071002, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Mass flow rate; Velocity averaging tube vortex (VATV); Flow sensor; Measurement model; Double differential pressure; FLOWMETER; SIMULATION; ORIFICE;
D O I
10.1016/j.energy.2023.129155
中图分类号
O414.1 [热力学];
学科分类号
摘要
Accurate mass flow rate measurement of fluid is one of the key technologies to ensure product quality and utilization of energy resources. However, the accuracy of traditional combined measuring devices is limited. In this paper, a new type of velocity averaging tube vortex flow sensor (VATV) is designed, and the mass flow rate measurement model is proposed and analyzed to achieve the high precision measurement of mass flow rate. The size, shape and structure of the VATV are designed in this study and there are no moving parts inside the integrated VATV. The method of double differential pressure is proposed to achieve the measurement of the average differential pressure signal and differential pressure fluctuation signal. Then, the method of Empirical Wavelet Transform (EWT) is used to extract the vortex shedding frequency from the differential pressure fluctuation signal. It indicated that the proposed VATV achieves an accuracy of +/- 0.50%, and the repeatability is also lower than 0.07%. A remarkable improvement of accuracy is achieved compared to the original combined measurement devices. The proposed sensor shows good prospect for the detection of gas-liquid two-phase flow such as wet stream due to the feature of strong anti-interference, high stability and reliability.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Measurement of mass flow rate using a vortex flowmeter
    Huang, YM
    Zhang, HJ
    Sun, ZQ
    PROCEEDINGS OF THE IEEE SENSORS 2003, VOLS 1 AND 2, 2003, : 344 - 347
  • [2] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Yeo, Seung Hwa
    Lee, Su Ryong
    Lee, Choong Hoon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (01) : 241 - 249
  • [3] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Seung Hwa Yeo
    Su Ryong Lee
    Choong Hoon Lee
    Journal of Mechanical Science and Technology, 2015, 29 : 241 - 249
  • [4] Application of averaging bidirectional flow tube for measurement of single-phase flow rate in a piping system
    Kyoung-Ho Kang
    Byong-Jo Yun
    Dong-Jin Euh
    Won-Pil Baek
    Journal of Mechanical Science and Technology, 2009, 23 : 758 - 767
  • [5] Application of averaging bidirectional flow tube for measurement of single-phase flow rate in a piping system
    Kang, Kyoung-Ho
    Yun, Byong-Jo
    Euh, Dong-Jin
    Baek, Won-Pil
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2009, 23 (03) : 758 - 767
  • [6] A mathematical model of the self-averaging Pitot tube - A mathematical model of a flow sensor
    Dobrowolski, B
    Kabacinski, M
    Pospolita, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (04) : 251 - 265
  • [7] Flow rate measurement in a pipe flow by vortex shedding
    Reik, M.
    Hoecker, R.
    Bruzzese, C.
    Hollmach, M.
    Koudal, O.
    Schenkel, T.
    Oertel, H.
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2010, 74 (02): : 77 - 86
  • [8] Thermal flow properties of a new micro flow sensor with wide range flow velocity measurement
    Kim, TY
    Chung, WY
    System Simulation and Scientific Computing, Vols 1 and 2, Proceedings, 2005, : 1079 - 1082
  • [9] Vortex tube and flow-rate characteristics
    Huang, Zhongyue
    He, Ying
    Cui, Xiuying
    Yu, Guofu
    Liu, Huisheng
    Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 1994, 34 (01): : 50 - 53
  • [10] A study of mass flow rate measurement based on the vortex shedding principle
    Zhang, HJ
    Huang, YM
    Sun, ZQ
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (01) : 29 - 38