Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases

被引:15
|
作者
Panthier, Frederic [1 ,2 ,3 ]
Solano, Catalina [1 ,2 ,4 ]
Chicaud, Marie [1 ,2 ,3 ,5 ]
Kutchukian, Stessy [1 ,2 ,3 ,6 ]
Candela, Luigi [1 ,2 ,7 ]
Doizi, Steeve [1 ,2 ,3 ]
Corrales, Mariela [1 ,2 ]
Traxer, Olivier [1 ,2 ]
机构
[1] Sorbonne Univ, Hop Tenon, Grp Rech Clin Lithiase Urinaire, GRC 20, F-75020 Paris, France
[2] Sorbonne Univ, Hop Tenon, Assistance Publ Hop Paris, Serv Urol, 4 Rue Chine, F-75020 Paris, France
[3] PIMM, CNRS Arts & Metiers ParisTech, UMR 8006, 151 Bd Hop, F-75013 Paris, France
[4] Uroclin SAS, Dept Endourol, Medellin, Colombia
[5] CHU Limoges, Serv Urol, F-87000 Limoges, France
[6] Univ Poitiers Hosp, Dept Urol, 2 Rue Miletrie, F-86000 Poitiers, France
[7] IRCCS Osped San Raffaele, Div Expt Oncol, Unit Urol, URI, Milan, Italy
关键词
Thulium YAG; Ureteroscopy; Laser; Lithotripsy; Volume; HOLMIUM;
D O I
10.1007/s00345-023-04501-0
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction Holmium: yttrium-aluminium-garnet (Ho:YAG) and thulium fiber (TFL) lasers are currently the two laser sources recommended for endocorporeal laser lithotripsy (ELL). Recently, the pulsed-thulium:YAG (Tm:YAG) laser was also proposed for ELL, as an answer to both Ho:YAG and TFL limitations. We aimed to evaluate the efficiency, safety, and laser settings of Tm:YAG laser in ELL during retrograde intrarenal surgery (RIRS). Methods A prospective study of the first 25 patients with ureteral and renal stones who underwent RIRS using the Thulio (pulsed-Tm:YAG, Dornier (c), Germany) was performed in a single center. 272 mu m laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm(3)/s), Joules/mm(3) and laser power (W) values for each procedure. Postoperative results, such as stone-free rate (SFR) and zero fragments rate (ZFR) were also recorded. Results A total of 25 patients were analyzed (Table 1). The median (IQR) age was 55 (44-72) years old. Median (IQR) stone volume was 2849 (916-9153)mm(3). Median (IQR) stone density was 1000 (600-1174)HU. Median (IQR) pulse energy, pulse rate and total power were 0.6 ( 0.6-0,8)J, 15(15-20)Hz and 12( 9-16)W, respectively. All procedures used "Captive Fragmenting" pulse modulation (Table 2). The median ( IQR) J/mm(3) was 14,8 (6-21). The median (IQR) ablation rate was 0,75 (0,46-2)mm(3)/s. One postoperative complications occurred (streinstrasse). SFR and ZFR were 95% and 55%, respectively. Conclusion The pulsed-Tm:YAG laser is a safe and effective laser source for lithotripsy during RIRS, using low pulse energy and low pulse frequency.
引用
收藏
页码:2119 / 2125
页数:7
相关论文
共 10 条
  • [1] Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases
    Frédéric Panthier
    Catalina Solano
    Marie Chicaud
    Stessy Kutchukian
    Luigi Candela
    Steeve Doizi
    Mariela Corrales
    Olivier Traxer
    World Journal of Urology, 2023, 41 : 2119 - 2125
  • [2] First Clinical Experience of a Novel Pulsed Solid-State Thulium:YAG Laser during Percutaneous Nephrolithotomy
    Bergmann, Julius
    Rosenbaum, Clemens Mathias
    Netsch, Christopher
    Gross, Andreas J. J.
    Becker, Benedikt
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [3] Initial clinical experience with the thulium fiber laser from Quanta System: First 50 reported cases
    Sierra, Alba
    Corrales, Mariela
    Kolvatzis, Merkourios
    Traxer, Olivier
    WORLD JOURNAL OF UROLOGY, 2022, 40 (10) : 2549 - 2553
  • [4] In vitro fragmentation performance of a novel, pulsed Thulium solid-state laser compared to a Thulium fibre laser and standard Ho:YAG laser
    Kraft, Lea
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Miernik, Arkadiusz
    LASERS IN MEDICAL SCIENCE, 2022, 37 (03) : 2071 - 2078
  • [5] Retropulsion force in laser lithotripsy—an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser
    Ralf Petzold
    Arkadiusz Miernik
    Rodrigo Suarez-Ibarrola
    World Journal of Urology, 2021, 39 : 3651 - 3656
  • [6] Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser
    Petzold, Ralf
    Miernik, Arkadiusz
    Suarez-Ibarrola, Rodrigo
    WORLD JOURNAL OF UROLOGY, 2021, 39 (09) : 3651 - 3656
  • [7] Temperature Assessment of a Novel Pulsed Thulium Solid-State Laser Compared with a Holmium:Yttrium-Aluminum-Garnet Laser
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Miernik, Arkadiusz
    JOURNAL OF ENDOUROLOGY, 2021, 35 (06) : 853 - 859
  • [8] Temperature profiles during ureteroscopy with thulium fiber laser and holmium:YAG laser: Findings from a pre-clinical study
    Aesoy, M. S.
    Juliebo-Jones, P.
    Beisland, C.
    Ulvik, O.
    SCANDINAVIAN JOURNAL OF UROLOGY, 2022, 56 (04) : 313 - 319
  • [9] PERCUTANEOUS LASER ANGIOPLASTY WITH A PULSED ND-YAG LASER - INITIAL CLINICAL-EXPERIENCE AND EARLY FOLLOW-UP
    KVASNICKA, J
    BOUDIK, F
    STANEK, F
    KUBECEK, V
    KRIVANEK, J
    KECLIK, R
    PROCHAZKOVA, H
    HAMAL, K
    INTERNATIONAL ANGIOLOGY, 1991, 10 (01) : 29 - 33
  • [10] Percutaneous photoacoustic debulking of infra-inguinal atherosclerotic disease- early European experience with a novel, solid-state, pulsed -wave, ultraviolet 355 nm laser
    Kuczmik, Waclaw
    Oszkinis, Grzegorz
    Kruszyna, Lukasz
    Stanisic, Michal Goran
    Zelawski, Wojciech
    Kostecki, Jacek
    Planer, David
    Leon Jr, Luis R.
    Muncher, Yossi
    Cohen, Oshrat
    Topaz, On
    LASERS IN MEDICAL SCIENCE, 2025, 40 (01)