Seismic retrofitting of beam to double-I built-up column moment connections by lateral T-stiffeners: Experimental and numerical study

被引:3
作者
Ayoubi, Mohammad Reza [1 ]
Ghobadi, Mohammad Soheil [1 ]
机构
[1] Imam Khomeini Int Univ, Fac Engn & Technol, Dept Civil Engn, Postal Code 34148, Qazvin, Iran
关键词
Double-I column; T-stiffeners; Seismic retrofit; Weld failure; Connections; Hysteresis curve; BOX-COLUMN; PERFORMANCE; BEHAVIOR; LESSONS;
D O I
10.1016/j.jcsr.2023.107875
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the present paper, the retrofitting of welded flange plate moment connections joined to double-I built-up columns is discussed by presenting the design method and details of construction retrofitting. Some of the usual construction problems of this connection include the defective complete joint penetration groove weld at the connection of the flange plate and the column, the large out-of-plane deformations of the column cover plate at the level of the beam-to-column connection, and as a result, its inappropriate seismic performance and the connection's partially restrained behavior. Thus, an attempt is made to evaluate the advantages of strengthening this defective connection with the help of lateral T-stiffeners using analytical and experimental studies. For this purpose, the experimental specimen and the high-fidelity finite element model are considered for both retrofitted and defective connections by evaluating the proposed design method, cyclic behavior of connection, collapse potential of weld fasteners, and failure modes. The results indicate that by using the proposed retrofitting method, the connection is classified in the group of fully restrained connections, while also having the necessary strength and ductility to accept the conditions of the special moment-resisting frames according to AISC seismic provisions. By performing a sensitivity analysis on the T-stiffener, changing its dimensions and examining the damage indices, the accuracy of the proposed design method is proven. The examinations indicate that the aforementioned retrofitting method is a proper method for the introduced defective connection.
引用
收藏
页数:17
相关论文
共 32 条
[1]  
Abaqus F., 2011, Analysis Users Manual 6.14
[2]  
[Anonymous], 1995, 1025 DIN
[3]  
[Anonymous], 2010, Metallic Materials-Tensile Testing-Part 1: Method of Test at Room Temperature
[4]  
[Anonymous], 2000, Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings
[5]  
[Anonymous], 2016, 689212006 BS EN ISO
[6]  
[Anonymous], 2016, 36016 ANSI AISC
[7]  
[Anonymous], 2014, 4113 ASCE SEI
[8]  
[Anonymous], 2007, 13912007 AS STAND AS
[9]  
[Anonymous], 2015, D11D11M AWS
[10]  
[Anonymous], 2016, 34116 ANSI AISC